For the slab shown in the figure, Fy= 420 Mpa, Col. Dimensions = 400 x 400 mm, check slab thickness at exterior panel for deflection control for the following cases: 1- Flat slab without edge beam and without drop panel 2- Use edge beam only. 3- Use Drop Panel only. 4- Use edge beam and drop panel. 5- Use beams for all lines with am=0.5. 6- Use beams for all lines with am = 1.5. 7- Use beams for all lines with um= 2.5. Discuss the results. 7.2 m 7.2 m 7.2m 7.2 m 7.2 m 7.2 m
For the slab shown in the figure, Fy= 420 Mpa, Col. Dimensions = 400 x 400 mm, check slab thickness at exterior panel for deflection control for the following cases: 1- Flat slab without edge beam and without drop panel 2- Use edge beam only. 3- Use Drop Panel only. 4- Use edge beam and drop panel. 5- Use beams for all lines with am=0.5. 6- Use beams for all lines with am = 1.5. 7- Use beams for all lines with um= 2.5. Discuss the results. 7.2 m 7.2 m 7.2m 7.2 m 7.2 m 7.2 m
Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter3: Tension Members
Section: Chapter Questions
Problem 3.3.1P
Related questions
Question
![:
۷:۲۹ ۱
1- Flat slab without edge beam
and without drop panel
2- Use edge beam only.
3- Use Drop Panel only.
4- Use edge beam and drop
panel.
5- Use beams for all lines with
am = 0.5.
For the slab shown in the figure, Fy= 420 Mpa, Col. Dimensions = 400 x 400 mm,
check slab thickness at exterior panel for deflection control for the following cases:
6- Use beams for all lines with
am = 1.5.
7- Use beams for all lines with
am= 2.5.
Discuss the results.
2_53528712391174...
AMX36 36.
7.2 m
7.2 m
****************…………………..
7.2m
7.2 m
7.2 m
7.2 m](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fcb933dad-058e-4149-aa34-772760c4a1ab%2Fb22458c2-6cef-483f-9ef7-02f18817e07b%2Flhuqxea_processed.jpeg&w=3840&q=75)
Transcribed Image Text::
۷:۲۹ ۱
1- Flat slab without edge beam
and without drop panel
2- Use edge beam only.
3- Use Drop Panel only.
4- Use edge beam and drop
panel.
5- Use beams for all lines with
am = 0.5.
For the slab shown in the figure, Fy= 420 Mpa, Col. Dimensions = 400 x 400 mm,
check slab thickness at exterior panel for deflection control for the following cases:
6- Use beams for all lines with
am = 1.5.
7- Use beams for all lines with
am= 2.5.
Discuss the results.
2_53528712391174...
AMX36 36.
7.2 m
7.2 m
****************…………………..
7.2m
7.2 m
7.2 m
7.2 m
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Steel Design (Activate Learning with these NEW ti…](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning
![Steel Design (Activate Learning with these NEW ti…](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning