For GC analysis, the following can cause band broadening and poor resolution OUse of automatic sampler Slow injection and oversize samples O Use of 5 m or longer packed column For samples of fatty acid methyl esters, alkaloids, drugs, and halogenated compounds, an applicable liquid stationary phase for GLC is Polyethylene glycol 50% Cyanopropyl-polydimethyl siloxane 5% Phenyl-polydimethyl siloxane

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
For GC analysis, the following can cause band broadening and poor
resolution
Use of automatic sampler
Slow injection and oversize samples
Use of 5 m or longer packed column
For samples of fatty acid methyl esters, alkaloids, drugs, and
halogenated compounds, an applicable liquid stationary phase for GLC
is
Polyethylene glycol
50% Cyanopropyl-polydimethyl siloxane
5% Phenyl-polydimethyl siloxane
A C18 column is an example of a "reverse phase" column. Reverse phase
columns are often used with more polar solvents such as water,
methanol or acetonitrile. The stationary phase is a nonpolar
hydrocarbon, whereas the mobile phase is a polar liquid. If a sample has
the following components, what will be the order of elution? (A.) 1,6-
Hexadiol (B.) 2,5-Hexadiol (C.) 2,3,4-Hexatriol
CBA
BCA
ABC
Transcribed Image Text:For GC analysis, the following can cause band broadening and poor resolution Use of automatic sampler Slow injection and oversize samples Use of 5 m or longer packed column For samples of fatty acid methyl esters, alkaloids, drugs, and halogenated compounds, an applicable liquid stationary phase for GLC is Polyethylene glycol 50% Cyanopropyl-polydimethyl siloxane 5% Phenyl-polydimethyl siloxane A C18 column is an example of a "reverse phase" column. Reverse phase columns are often used with more polar solvents such as water, methanol or acetonitrile. The stationary phase is a nonpolar hydrocarbon, whereas the mobile phase is a polar liquid. If a sample has the following components, what will be the order of elution? (A.) 1,6- Hexadiol (B.) 2,5-Hexadiol (C.) 2,3,4-Hexatriol CBA BCA ABC
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY