Fill in the blank (word in bracket) with the appropriate word from the list of words given below. Cogeneration | regeneration | constant | superheating | reheated | lowering | increased Combined cycles | higher | combined cycle The thermal efficiency of the Rankine cycle can be increased by increasing the average temperature at which heat is transferred to the working fluid and/or by decreasing the average temperature at which heat is rejected to the cooling medium. The average temperature during heat rejection can be decreased by the turbine exit pressure. Consequently, the condenser pressure of most vapor power plants is well below the atmospheric pressure. The average temperature during heat addition can be by raising the boiler pressure or by the fluid to high temperatures. Lowering the exhaust pressure or raising the boiler pressure, however, increases the moisture content. To take advantage of the improved efficiencies at higher boiler pressures and lower condenser pressures, steam is usually after expanding partially in the high-pressure turbine. This is done at by extracting the steam after partial expansion in the high-pressure turbine, sending it back to the boiler where it is pressure, and returning it to the low-pressure turbine for complete expansion to the condenser pressure. During a process, liquid water Another way of increasing the thermal efficiency of the Rankine cycle is (feedwater) leaving the pump is heated by steam bled off the turbine at some intermediate pressure in devices called feedwater heaters. The production of more than one useful form of energy (such as process heat and electric power) from the same energy source is called The most common is the The overall thermal efficiency of a power plant can be increased by using a gas-steam combined cycle where a gas-turbine cycle operates at the high-temperature range and a steam-turbine cycle at the low-temperature range. Steam is heated by the high-temperature exhaust gases leaving the gas turbine. have a thermal efficiency than the steam- or gas-turbine cycles operating alone.
Fill in the blank (word in bracket) with the appropriate word from the list of words given below. Cogeneration | regeneration | constant | superheating | reheated | lowering | increased Combined cycles | higher | combined cycle The thermal efficiency of the Rankine cycle can be increased by increasing the average temperature at which heat is transferred to the working fluid and/or by decreasing the average temperature at which heat is rejected to the cooling medium. The average temperature during heat rejection can be decreased by the turbine exit pressure. Consequently, the condenser pressure of most vapor power plants is well below the atmospheric pressure. The average temperature during heat addition can be by raising the boiler pressure or by the fluid to high temperatures. Lowering the exhaust pressure or raising the boiler pressure, however, increases the moisture content. To take advantage of the improved efficiencies at higher boiler pressures and lower condenser pressures, steam is usually after expanding partially in the high-pressure turbine. This is done at by extracting the steam after partial expansion in the high-pressure turbine, sending it back to the boiler where it is pressure, and returning it to the low-pressure turbine for complete expansion to the condenser pressure. During a process, liquid water Another way of increasing the thermal efficiency of the Rankine cycle is (feedwater) leaving the pump is heated by steam bled off the turbine at some intermediate pressure in devices called feedwater heaters. The production of more than one useful form of energy (such as process heat and electric power) from the same energy source is called The most common is the The overall thermal efficiency of a power plant can be increased by using a gas-steam combined cycle where a gas-turbine cycle operates at the high-temperature range and a steam-turbine cycle at the low-temperature range. Steam is heated by the high-temperature exhaust gases leaving the gas turbine. have a thermal efficiency than the steam- or gas-turbine cycles operating alone.
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
100%
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY