building in Noida, U.P. The data are as follows: Consider an inner beam-column joint in the ground floor roof of a eight storey Grade of concrete = M25, steel grade = Fe 415 D %3D Clear span of beam to the left side of the joint 4.5 m Clear span of beam to the right side of the joint 4 m %3D Slab thickness = 125 mm, finish on slab 50 mm thick %3D Live load on floor = 2 kN/m²; Wall thickness on beams = 115 mm %3D The axial load in column at the joint 900 kN %3D Beam size = 230 mm x 550 mm with 1.5% steel at top (3 – 25 mm and 2 - 16 mm ) and 0.8% steel at bottom on either side of the joint. Column size = 230 m x 650 mm with 3.46% steel %3D (8 – 25mm and 4- 20 mm bars) Check if the joint satisfies weak girder-strong column proportion. Also check the shear in beam and column.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question

Consider an inner beam-column joint i sn ground floor roof of a eight storey
building in Noida, U.P. The data are as follows:
Grade of concrete = M25, steel grade
= Fe 415 D
Clear
of beam to the left side of the joint
span
4.5 m
Clear span of beam to the right side of the joint
= 4 m
125
Live load on floor =
Slab thickness
finish on slab = 50 mm thick
mm,
2 kN/m“;
Wall thickness on beams =
115 mm
The axial load in column at the joint
= 900 kN
230 mm x 550 mm with 1.5% steel at top (3 - 25
mm and 2 - 16 mm ) and 0.8% steel at bottom on
either side of the joint.
Beam size
Column size =
230 m x 650 mm with 3.46% steel
(8 – 25mm and 4- 20 mm bars)
Check if the joint satisfies weak girder-strong column proportion. Also check the
shear in beam and column.
Transcribed Image Text:Consider an inner beam-column joint i sn ground floor roof of a eight storey building in Noida, U.P. The data are as follows: Grade of concrete = M25, steel grade = Fe 415 D Clear of beam to the left side of the joint span 4.5 m Clear span of beam to the right side of the joint = 4 m 125 Live load on floor = Slab thickness finish on slab = 50 mm thick mm, 2 kN/m“; Wall thickness on beams = 115 mm The axial load in column at the joint = 900 kN 230 mm x 550 mm with 1.5% steel at top (3 - 25 mm and 2 - 16 mm ) and 0.8% steel at bottom on either side of the joint. Beam size Column size = 230 m x 650 mm with 3.46% steel (8 – 25mm and 4- 20 mm bars) Check if the joint satisfies weak girder-strong column proportion. Also check the shear in beam and column.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Design criteria for structural loading
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning