B- the instrument readings obtained from open and short-circuit tests on 10kVA, 450/120V, 50Hz transformer are: O.C. test: V₁ = 120V; I₁= 4.2A; W₁ = 80W; W₁ and I were read on the low-voltage side. S.C. test: V₁ = 8.5V; 1₁-20A; W₁ = 100W with low voltage winding short-circuited compute: 1- the equivalent circuit constants referred to high voltage side. 2- efficiency and voltage regulation for full-load at 0.8 P.F. lagging. 3- the voltage to be applied to the high voltage side on full-load at 0.8 power factor lag when the secondary load voltage is 120V. Luoltage:

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
B. the instrument readings obtained from open and short-circuit tests on 10kVA, 450/120V,
50Hz transformer are:
O.C. test: V₁ = 120V; I₁= 4.2A; W₁ = 80W; W₁ and I were read on the low-voltage side.
S.C. test: V₁ = 8.5V; 1₁ -20A; W₁ = 100W with low voltage winding short-circuited compute:
1- the equivalent circuit constants referred to high voltage side.
2- efficiency and voltage regulation for full-load at 0.8 P.F. lagging.
3- the voltage to be applied to the high voltage side on full-load at 0.8 power factor lag when the
secondary load voltage is 120V.
4- if the transformer terminals are short circuited accidently when working at normal voltage;
calculate the approximate value of the short circuit current in secondary winding.
5- calculate the maximum regulation at full-load.
Transcribed Image Text:B. the instrument readings obtained from open and short-circuit tests on 10kVA, 450/120V, 50Hz transformer are: O.C. test: V₁ = 120V; I₁= 4.2A; W₁ = 80W; W₁ and I were read on the low-voltage side. S.C. test: V₁ = 8.5V; 1₁ -20A; W₁ = 100W with low voltage winding short-circuited compute: 1- the equivalent circuit constants referred to high voltage side. 2- efficiency and voltage regulation for full-load at 0.8 P.F. lagging. 3- the voltage to be applied to the high voltage side on full-load at 0.8 power factor lag when the secondary load voltage is 120V. 4- if the transformer terminals are short circuited accidently when working at normal voltage; calculate the approximate value of the short circuit current in secondary winding. 5- calculate the maximum regulation at full-load.
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,