A quality control (QC) sample was run in replicates of six to produce the following concentrations values: 12.2, 11.6, 11.9, 12.3, 12.8, and 11.7 ug/L. Is this level of analytical method precision acceptable for this group of QC replicates? O 3.3%, YES O 3.3%, NO O 5.5%, YES O 5.5% NO Question 9 Determine the correct answer for the following question: One definition of analytical method accuracy in a GLP laboratory is +20 percent relative error (RE) or the measured mean sample concentration to that of the true concentration such that %re [(Measured Mean Concentration - True Concentration)/True Concentration] x 100 A single quality control (QC) sample was prepared at a concentration of 12.5 ug/L and run in replicates of six to produce the following concentrations values: 12.5, 11.9, 14.2, 12.2, 13.7, and 14.1 ug/L. Is this level of analytical method accuracy acceptable for this QC sample?
A quality control (QC) sample was run in replicates of six to produce the following concentrations values: 12.2, 11.6, 11.9, 12.3, 12.8, and 11.7 ug/L. Is this level of analytical method precision acceptable for this group of QC replicates? O 3.3%, YES O 3.3%, NO O 5.5%, YES O 5.5% NO Question 9 Determine the correct answer for the following question: One definition of analytical method accuracy in a GLP laboratory is +20 percent relative error (RE) or the measured mean sample concentration to that of the true concentration such that %re [(Measured Mean Concentration - True Concentration)/True Concentration] x 100 A single quality control (QC) sample was prepared at a concentration of 12.5 ug/L and run in replicates of six to produce the following concentrations values: 12.5, 11.9, 14.2, 12.2, 13.7, and 14.1 ug/L. Is this level of analytical method accuracy acceptable for this QC sample?
Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
Related questions
Question
![Determine the correct answer for the following.question:
A quality control (QC) sample was run in replicates of six to produce the following concentrations
values: 12.2, 11.6, 11.9, 12.3, 12.8, and 11.7 ug/L. Is this level of analytical method precision
acceptable for this group of QC replicates?
O 3.3%, YES
O 3.3%, NO
O 5.5%, YES
O 5.5% NO
Question 9
Determine the correct answer for the following question:
One definition of analytical method accuracy in a GLP laboratory is +20 percent relative error (RE) of
the measured mean sample concentration to that of the true concentration such that
%re = [(Measured Mean Concentration - True Concentration)/True Concentration] x 100
A single quality control (QC) sample was prepared at a concentration of 12.5 ug/Land run in
replicates of six to produce the following concentrations values: 12.5, 11.9, 14.2, 12.2, 13.7, and
14.1 ug/L. Is this level of analytical method accuracy acceptable for this QC sample?](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F4502b244-c869-4455-86b7-4959f1f25f8f%2F5261311f-f24e-43c5-ab54-271af775f616%2F3w0dyb4_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Determine the correct answer for the following.question:
A quality control (QC) sample was run in replicates of six to produce the following concentrations
values: 12.2, 11.6, 11.9, 12.3, 12.8, and 11.7 ug/L. Is this level of analytical method precision
acceptable for this group of QC replicates?
O 3.3%, YES
O 3.3%, NO
O 5.5%, YES
O 5.5% NO
Question 9
Determine the correct answer for the following question:
One definition of analytical method accuracy in a GLP laboratory is +20 percent relative error (RE) of
the measured mean sample concentration to that of the true concentration such that
%re = [(Measured Mean Concentration - True Concentration)/True Concentration] x 100
A single quality control (QC) sample was prepared at a concentration of 12.5 ug/Land run in
replicates of six to produce the following concentrations values: 12.5, 11.9, 14.2, 12.2, 13.7, and
14.1 ug/L. Is this level of analytical method accuracy acceptable for this QC sample?
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 2 images

Recommended textbooks for you

Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning

Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education

Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning

Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY