A 380V, 50H2, A-connected, 6-pole SG has a per-phase synchronous reactance of 0.8Q. Its full- load armature current is 65A at 0.82 PF lagging. This generator has Pt+w=1.2kW and Peore=0.8kW at 60HZ at full load. Its armature resistance is being ignored. The field current has been adjusted so that the terminal voltage is 380V at no load. 1. Find the speed of rotation of this generator? 2. Find the terminal voltage if it is loaded with the rated current at 0.82 PF leading. 3. Find the efficiency when it is operating at the rated current at 0.82 PF leading. 4. Find the voltage regulation of this generator at 0.82 PF leading

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A 380V, 50HZ, A-connected, 6-pole SG has a per-phase synchronous reactance of 0.82. Its full-
load armature current is 65A at 0.82 PF lagging. This generator has Ptw=1.2kW and Pcore=0.8kW
at 60HZ at full load. Its armature resistance is being ignored. The field current has been adjusted
so that the terminal voltage is 380V at no load.
1. Find the speed of rotation of this generator?
2. Find the terminal voltage if it is loaded with the rated current at 0.82 PF leading.
3. Find the efficiency when it is operating at the rated current at 0.82 PF leading.
4. Find the voltage regulation of this generator at 0.82 PF leading
Transcribed Image Text:A 380V, 50HZ, A-connected, 6-pole SG has a per-phase synchronous reactance of 0.82. Its full- load armature current is 65A at 0.82 PF lagging. This generator has Ptw=1.2kW and Pcore=0.8kW at 60HZ at full load. Its armature resistance is being ignored. The field current has been adjusted so that the terminal voltage is 380V at no load. 1. Find the speed of rotation of this generator? 2. Find the terminal voltage if it is loaded with the rated current at 0.82 PF leading. 3. Find the efficiency when it is operating at the rated current at 0.82 PF leading. 4. Find the voltage regulation of this generator at 0.82 PF leading
Expert Solution
steps

Step by step

Solved in 9 steps with 2 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,