Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature resistance of 0.05 Q. Each of generators G1, G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz, respectively The no-load frequency of each generator is set to 52.4 Hz. The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first. At what system frequency does this limit occur? Select one: O a. fays = 48.97 Hz O b. fsys = 48.25 Hz c. fsys = 49.22 Hz O d. None

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Three identical steam-turbine generators G1, G2, and G3 are operating in parallel.
Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature
resistance of 0.05 Q.
Each of generators G1 , G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz,
respectively The no-load frequency of each generator is set to 52.4 Hz.
The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first.
At what system frequency does this limit occur?
Select one:
O a. fsys = 48.97 Hz
O b. fsys = 48.25 Hz
c. fsys = 49.22 Hz
O d. None
Transcribed Image Text:Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature resistance of 0.05 Q. Each of generators G1 , G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz, respectively The no-load frequency of each generator is set to 52.4 Hz. The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first. At what system frequency does this limit occur? Select one: O a. fsys = 48.97 Hz O b. fsys = 48.25 Hz c. fsys = 49.22 Hz O d. None
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,