Three-phase, 400 V (line voltage), 60 Hz, 6-pole, star-connected synchronous generator has a synchronous reactance of 1.2 ohms per phase. The armature current of the generator at full load is 64 A at a back power factor of 0.95. This generator has a rotational loss of 2 kW and a core loss of 1.6 kW at full load. The excitation current is adjusted so that the output voltage is 400V (line voltage) when the generator is running at no load. When the generator is loaded with 0.95 back power factor current at full load A) Find the rotating field speed of the generator? B) Find the mechanical speed of the generator? C) What will be the output voltage? D) Find the yield? E) Calculate the voltage regulation?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Plz quickly
Three-phase, 400 V (line voltage), 60 Hz, 6-pole,
star-connected synchronous generator has a
synchronous reactance of 1.2 ohms per phase.
The armature current of the generator at full
load is 64 A at a back power factor of 0.95. This
generator has a rotational loss of 2 kW and a
core loss of 1.6 kW at full load. The excitation
current is adjusted so that the output voltage
is 400V (line voltage) when the generator is
running at no load. When the generator is
loaded with 0.95 back power factor current at
full load
A) Find the rotating field speed of the generator?
B) Find the mechanical speed of the generator?
C) What will be the output voltage?
D) Find the yield?
E) Calculate the voltage regulation?
Transcribed Image Text:Three-phase, 400 V (line voltage), 60 Hz, 6-pole, star-connected synchronous generator has a synchronous reactance of 1.2 ohms per phase. The armature current of the generator at full load is 64 A at a back power factor of 0.95. This generator has a rotational loss of 2 kW and a core loss of 1.6 kW at full load. The excitation current is adjusted so that the output voltage is 400V (line voltage) when the generator is running at no load. When the generator is loaded with 0.95 back power factor current at full load A) Find the rotating field speed of the generator? B) Find the mechanical speed of the generator? C) What will be the output voltage? D) Find the yield? E) Calculate the voltage regulation?
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Z-transform of Signal
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,