5.3 A small power system consists of two buses connected by three transmission lines. Assuming that this power system must be operated according to the N-1 security criterion and that its operation is constrained only by thermal limits on the transmission lines, calculate the maximum power transfer between these two buses for each of the following conditions а. All three lines are in service and each line has a continuous thermal rating of 300 MW b. Only two lines rated at 300 MW are in service c. All three lines are in service. Two of them have a continuous thermal rating с. of 300 MW and the third is rated at 200 MW. 138 5 SYSTEM SECURITY AND ANCILLARY SERVICES d. All three lines are in service. All of them have a continuous thermal rating of 300 MW. However, during emergencies, they can sustain a 10% overload for 20 min. The generating units on the downstream bus can increase their output at the rate of 4 MW per minute. e. Same conditions as in (d), except that the output of the downstream gener- ators can only increase at the rate of 2 MW per minute. f. Low temperatures and high winds improve the heat transfer between the conductors and the atmosphere. Assume that this dynamic thermal rating increases the continuous and emergency loadings of (d) by 15%.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
5.3 A small power system consists of two buses connected by three transmission
lines. Assuming that this power system must be operated according to the N-1
security criterion and that its operation is constrained only by thermal limits on
the transmission lines, calculate the maximum power transfer between these two
buses for each of the following conditions
а.
All three lines are in service and each line has a continuous thermal rating
of 300 MW
b.
Only two lines rated at 300 MW are in service
c. All three lines are in service. Two of them have a continuous thermal rating
с.
of 300 MW and the third is rated at 200 MW.
138
5 SYSTEM SECURITY AND ANCILLARY SERVICES
d. All three lines are in service. All of them have a continuous thermal rating
of 300 MW. However, during emergencies, they can sustain a 10% overload
for 20 min. The generating units on the downstream bus can increase their
output at the rate of 4 MW per minute.
Same conditions as in (d), except that the output of the downstream gener-
ators can only increase at the rate of 2 MW per minute.
f. Low temperatures and high winds improve the heat transfer between the
conductors and the atmosphere. Assume that this dynamic thermal rating
increases the continuous and emergency loadings of (d) by 15%.
Transcribed Image Text:5.3 A small power system consists of two buses connected by three transmission lines. Assuming that this power system must be operated according to the N-1 security criterion and that its operation is constrained only by thermal limits on the transmission lines, calculate the maximum power transfer between these two buses for each of the following conditions а. All three lines are in service and each line has a continuous thermal rating of 300 MW b. Only two lines rated at 300 MW are in service c. All three lines are in service. Two of them have a continuous thermal rating с. of 300 MW and the third is rated at 200 MW. 138 5 SYSTEM SECURITY AND ANCILLARY SERVICES d. All three lines are in service. All of them have a continuous thermal rating of 300 MW. However, during emergencies, they can sustain a 10% overload for 20 min. The generating units on the downstream bus can increase their output at the rate of 4 MW per minute. Same conditions as in (d), except that the output of the downstream gener- ators can only increase at the rate of 2 MW per minute. f. Low temperatures and high winds improve the heat transfer between the conductors and the atmosphere. Assume that this dynamic thermal rating increases the continuous and emergency loadings of (d) by 15%.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,