5. Suppose that you made a mistake when you set up the thermocycler program and omitted the first 2 minutes at 95°C. How would this impact your PCR? 5. Suppose that you made a mistake when you set up the thermocycler program and only programmed for 10 cycles instead of 30 cycles. How would this impact your PCR?

Human Anatomy & Physiology (11th Edition)
11th Edition
ISBN:9780134580999
Author:Elaine N. Marieb, Katja N. Hoehn
Publisher:Elaine N. Marieb, Katja N. Hoehn
Chapter1: The Human Body: An Orientation
Section: Chapter Questions
Problem 1RQ: The correct sequence of levels forming the structural hierarchy is A. (a) organ, organ system,...
icon
Related questions
Question
Need help with question 5 and 6
Exercise II
4. Complete the following table to calculate what volume of primers to add to your PCR master mix:
Per Sample
Master Mix
Added to
Reagent
1X
3.5X
Master Mix?
Water
19.9 ul
69.7 µl
Buffer (10X with Mg2+)
2.5 μι
8.8 μ
Forward Primer (M13F), 10 µM
1 ul
3.5
Reverse Primer (M13R), 10 µM
1 ul
3.5
DNTPS (10 mM each, 40 mM total)
0.5 ul
1.8 μι
Taq Polymerase
0.1 pl
0.4 ul
Total Volume
25 μι
87.5 µl
50
Have your Lab Instructor check your calculations before you add any reagents to your master mix.
W Lab Instructor Initials:
5. Suppose that you made a mistake when you set up the thermocycler program and omitted the
first 2 minutes at 95°C. How would this impact your PCR?
6. Suppose that you made a mistake when you set up the thermocycler program and only
programmed for 10 cycles instead of 30 cycles. How would this impact your PCR?
Transcribed Image Text:Exercise II 4. Complete the following table to calculate what volume of primers to add to your PCR master mix: Per Sample Master Mix Added to Reagent 1X 3.5X Master Mix? Water 19.9 ul 69.7 µl Buffer (10X with Mg2+) 2.5 μι 8.8 μ Forward Primer (M13F), 10 µM 1 ul 3.5 Reverse Primer (M13R), 10 µM 1 ul 3.5 DNTPS (10 mM each, 40 mM total) 0.5 ul 1.8 μι Taq Polymerase 0.1 pl 0.4 ul Total Volume 25 μι 87.5 µl 50 Have your Lab Instructor check your calculations before you add any reagents to your master mix. W Lab Instructor Initials: 5. Suppose that you made a mistake when you set up the thermocycler program and omitted the first 2 minutes at 95°C. How would this impact your PCR? 6. Suppose that you made a mistake when you set up the thermocycler program and only programmed for 10 cycles instead of 30 cycles. How would this impact your PCR?
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Immune disorders
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Human Anatomy & Physiology (11th Edition)
Human Anatomy & Physiology (11th Edition)
Biology
ISBN:
9780134580999
Author:
Elaine N. Marieb, Katja N. Hoehn
Publisher:
PEARSON
Biology 2e
Biology 2e
Biology
ISBN:
9781947172517
Author:
Matthew Douglas, Jung Choi, Mary Ann Clark
Publisher:
OpenStax
Anatomy & Physiology
Anatomy & Physiology
Biology
ISBN:
9781259398629
Author:
McKinley, Michael P., O'loughlin, Valerie Dean, Bidle, Theresa Stouter
Publisher:
Mcgraw Hill Education,
Molecular Biology of the Cell (Sixth Edition)
Molecular Biology of the Cell (Sixth Edition)
Biology
ISBN:
9780815344322
Author:
Bruce Alberts, Alexander D. Johnson, Julian Lewis, David Morgan, Martin Raff, Keith Roberts, Peter Walter
Publisher:
W. W. Norton & Company
Laboratory Manual For Human Anatomy & Physiology
Laboratory Manual For Human Anatomy & Physiology
Biology
ISBN:
9781260159363
Author:
Martin, Terry R., Prentice-craver, Cynthia
Publisher:
McGraw-Hill Publishing Co.
Inquiry Into Life (16th Edition)
Inquiry Into Life (16th Edition)
Biology
ISBN:
9781260231700
Author:
Sylvia S. Mader, Michael Windelspecht
Publisher:
McGraw Hill Education