4.8. A three-phase transposed line is composed of one ACSR 159,000 cmil, 54/19 Lapwing conductor per phase with flat horizontal spacing of 8 meters as shown in Figure 37. The GMR of each conductor is 1.515 cm. (a) Determine the inductance per phase per kilometer of the line. (b) This line is to be replaced by a two-conductor bundle with 8-m spacing mea- sured from the center of the bundles as shown in Figure 38. The spacing between the conductors in the bundle is 40 cm. If the line inductance per phase is to be 77 percent of the inductance in part (a), what would be the GM R of each new conductor in the bundle? - D12 = 8 m D23 = 8 m -D13 = 16 m- %3D FIGURE 37 Conductor layout for Problem 4.8 (a).
4.8. A three-phase transposed line is composed of one ACSR 159,000 cmil, 54/19 Lapwing conductor per phase with flat horizontal spacing of 8 meters as shown in Figure 37. The GMR of each conductor is 1.515 cm. (a) Determine the inductance per phase per kilometer of the line. (b) This line is to be replaced by a two-conductor bundle with 8-m spacing mea- sured from the center of the bundles as shown in Figure 38. The spacing between the conductors in the bundle is 40 cm. If the line inductance per phase is to be 77 percent of the inductance in part (a), what would be the GM R of each new conductor in the bundle? - D12 = 8 m D23 = 8 m -D13 = 16 m- %3D FIGURE 37 Conductor layout for Problem 4.8 (a).
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.18P: A 230-kV, 60-Hz, three-phase completely transposed overhead line has one ACSR 954 kcmil conductor...
Related questions
Question
100%
![4.8. A three-phase transposed line is composed of one ACSR 159,000 cmil, 54/19
Lapwing conductor per phase with flat horizontal spacing of 8 meters as shown in
Figure 37. The GMR of each conductor is 1.515 cm.
(a) Determine the inductance per phase per kilometer of the line.
(b) This line is to be replaced by a two-conductor bundle with 8-m spacing mea-
sured from the center of the bundles as shown in Figure 38. The spacing between
the conductors in the bundle is 40 cm. If the line inductance per phase is to be
77 percent of the inductance in part (a), what would be the GM R of each new
conductor in the bundle?
a
D12 = 8 m
D23 = 8 m
%3D
%3D
-D13 = 16 m-
FIGURE 37
Conductor layout for Problem 4.8 (a).](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Ff8be024b-6df6-441b-b4d5-b509e16ab9e1%2F9ee78906-d05c-40d5-b06a-a3e46f3e56ba%2F2uuwzq_processed.png&w=3840&q=75)
Transcribed Image Text:4.8. A three-phase transposed line is composed of one ACSR 159,000 cmil, 54/19
Lapwing conductor per phase with flat horizontal spacing of 8 meters as shown in
Figure 37. The GMR of each conductor is 1.515 cm.
(a) Determine the inductance per phase per kilometer of the line.
(b) This line is to be replaced by a two-conductor bundle with 8-m spacing mea-
sured from the center of the bundles as shown in Figure 38. The spacing between
the conductors in the bundle is 40 cm. If the line inductance per phase is to be
77 percent of the inductance in part (a), what would be the GM R of each new
conductor in the bundle?
a
D12 = 8 m
D23 = 8 m
%3D
%3D
-D13 = 16 m-
FIGURE 37
Conductor layout for Problem 4.8 (a).
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning