3 Consider the one-line diagram of power system shown below; if a bolted three-phase fault (F1) occurs at the receiving end of the transmission line as shown: Gi 1 100 MVA, 11/132 kV 10% Reactance 100 MVA, 11 kV 15% Reactance Ti X-0.2 olm/phase/km G2 T2 200 km 50 MVA, 11 kV 10% Reactance 3 ph F1 faui F2 50 MVA, 11/132 kV 8% Reactance a) Develop equivalent circuit expressing all parameters in per unit values select Sbase= 100MVA b) Apply circuit reduction techniques and then find the net impedance(Zeg) at point of fault F1 c) Calculate fault level and fault current

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
3 Consider the one-line diagram of power system shown below; if a bolted three-phase
fault (F1) occurs at the receiving end of the transmission line as shown:
100 MVA, 11/132 kV
10% Reactance
100 MVA,
11 kV
15% Reactance
X=0.2 olm/phase/km
G2
T2
200 km
50 MVA,
3 ph
11 kV
F2
Jaul F1
50 MVA, 11/132 kV
8% Reactance
10% Reactance
a) Develop equivalent circuit expressing all parameters in per unit values select Sbase=
100MVA
b) Apply circuit reduction techniques and then find the net impedance(Zeg) at point of
fault F1
c) Calculate fault level and fault current
d) Repeat b and c if the fault(F2) occurs at the middle of one of the transmission line
Dr. Keerthivasan Krishnamoorthy EEE section
56
Enginccring Department Sem 2, 2017-2018 version 2.0
Transcribed Image Text:3 Consider the one-line diagram of power system shown below; if a bolted three-phase fault (F1) occurs at the receiving end of the transmission line as shown: 100 MVA, 11/132 kV 10% Reactance 100 MVA, 11 kV 15% Reactance X=0.2 olm/phase/km G2 T2 200 km 50 MVA, 3 ph 11 kV F2 Jaul F1 50 MVA, 11/132 kV 8% Reactance 10% Reactance a) Develop equivalent circuit expressing all parameters in per unit values select Sbase= 100MVA b) Apply circuit reduction techniques and then find the net impedance(Zeg) at point of fault F1 c) Calculate fault level and fault current d) Repeat b and c if the fault(F2) occurs at the middle of one of the transmission line Dr. Keerthivasan Krishnamoorthy EEE section 56 Enginccring Department Sem 2, 2017-2018 version 2.0
Expert Solution
steps

Step by step

Solved in 4 steps with 5 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,