2a) Calculate the illuminance at points P1 and P2. Source of light 1400 cd Source of light 1000 cd 3 m P1 P2 -1.8 m- 2 m- NOT TO SCALE
2a) Calculate the illuminance at points P1 and P2. Source of light 1400 cd Source of light 1000 cd 3 m P1 P2 -1.8 m- 2 m- NOT TO SCALE
Related questions
Question
100%
B2
![2a) Calculate the illuminance at points P1 and P2.
Source of light 1400 cd
Source of light 1000 cd
3 m
P1
P2
1.8 m-
2 m-
NOT TO SCALE
2b) Briefly outline the practical limitations of using 'point source' calculations and name the
method used to overcome this. (Hint: it is a calculation).](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fccae7901-d6b8-4b73-9809-93220eb9bcb7%2F66c3b857-e65e-4ad3-802a-c77ca1c47d0d%2Fqi3cvv_processed.jpeg&w=3840&q=75)
Transcribed Image Text:2a) Calculate the illuminance at points P1 and P2.
Source of light 1400 cd
Source of light 1000 cd
3 m
P1
P2
1.8 m-
2 m-
NOT TO SCALE
2b) Briefly outline the practical limitations of using 'point source' calculations and name the
method used to overcome this. (Hint: it is a calculation).
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 5 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)