2. The average wastewater flow from a community of 20,000 is 125 gpcd. The 5 day, 20 deg C BOD is 250 mg/L. The suspended solids content is 300 mg/L. A final plant effluent of 50 mg/L of BOD is to be achieved through the use of two sets of identical settling tanks and trickling filters operating in parallel. The settling tanks are to be designed to a standard of 1000 gpd/^2. The trickling filters are to be 6^ deep and operated at an organic loading of 55 lbm/1000^3 d. There is no recirculalon. (1) What settling tank surface area is required? In ft^2 (2) What settling tank diameter is required? In ft (3) Estimate the BOD removal in the settling tanks? In percent % (4) What is the trickling filter diameter? In ft File Explorer Expert Q&A | Cheg... (66) These

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question
2. The average wastewater flow from a community of 20,000 is 125 gpcd. The 5 day, 20 deg C
BOD is 250 mg/L. The suspended solids content is 300 mg/L. A final plant effluent of 50 mg/L of
BOD is to be achieved through the use of two sets of identical settling tanks and trickling filters
operating in parallel. The settling tanks are to be designed to a standard of 1000 gpd/^2. The
trickling filters are to be 6^ deep and operated at an organic loading of 55 lbm/1000^3 d.
There is no recirculalon.
(1) What settling tank surface area is required? In ft^2
(2) What settling tank diameter is required? In ft
(3) Estimate the BOD removal in the settling tanks? In percent %
(4) What is the trickling filter diameter? In ft
File Explorer
O
Expert Q&A | Cheq...
(66) These
Transcribed Image Text:2. The average wastewater flow from a community of 20,000 is 125 gpcd. The 5 day, 20 deg C BOD is 250 mg/L. The suspended solids content is 300 mg/L. A final plant effluent of 50 mg/L of BOD is to be achieved through the use of two sets of identical settling tanks and trickling filters operating in parallel. The settling tanks are to be designed to a standard of 1000 gpd/^2. The trickling filters are to be 6^ deep and operated at an organic loading of 55 lbm/1000^3 d. There is no recirculalon. (1) What settling tank surface area is required? In ft^2 (2) What settling tank diameter is required? In ft (3) Estimate the BOD removal in the settling tanks? In percent % (4) What is the trickling filter diameter? In ft File Explorer O Expert Q&A | Cheq... (66) These
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 12 images

Blurred answer
Knowledge Booster
Integrated solid waste management
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning