1. You were fortunate to use a pre-packed column in this experiment. List two methods you could use to pack a column should you ever need to do it yourself. 2. Each of the following could lead to poor liquid chromatographic separation. Explain how or why each one would decrease the separation of two molecules. a. collection of large elution fractions b. very slow flow rate of mobile phase c. too weak of an adsorbent 3. When 2-propanol was used as the developing solvent, two substances moved with the solvent front (R₁ = 1) during TLC analysis on a silica gel plate. Can you conclude that the two compounds are identical? If not, what additional TLC experiment(s) would you perform to investigate further?

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
1. You were fortunate to use a pre-packed column in this experiment. List two methods you
could use to pack a column should you ever need to do it yourself.
2. Each of the following could lead to poor liquid chromatographic separation. Explain how
or why each one would decrease the separation of two molecules.
a. collection of large elution fractions
b. very slow flow rate of mobile phase
c. too weak of an adsorbent
3. When 2-propanol was used as the developing solvent, two substances moved with the
solvent front (R₁ = 1) during TLC analysis on a silica gel plate. Can you conclude that the
two compounds are identical? If not, what additional TLC experiment(s) would you
perform to investigate further?
Transcribed Image Text:1. You were fortunate to use a pre-packed column in this experiment. List two methods you could use to pack a column should you ever need to do it yourself. 2. Each of the following could lead to poor liquid chromatographic separation. Explain how or why each one would decrease the separation of two molecules. a. collection of large elution fractions b. very slow flow rate of mobile phase c. too weak of an adsorbent 3. When 2-propanol was used as the developing solvent, two substances moved with the solvent front (R₁ = 1) during TLC analysis on a silica gel plate. Can you conclude that the two compounds are identical? If not, what additional TLC experiment(s) would you perform to investigate further?
AI-Generated Solution
AI-generated content may present inaccurate or offensive content that does not represent bartleby’s views.
steps

Unlock instant AI solutions

Tap the button
to generate a solution

Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY