1. Atoms are ionized and accelerated. Ions of a particular velocity are selected to enter the spectrometer. 2. Ions of different masses follow paths of different radii. B 2r Detector 3. Only ions of a particular mass reach the exit slit and continue to the detector. FIGURE P24.67

Human Anatomy & Physiology (11th Edition)
11th Edition
ISBN:9780134580999
Author:Elaine N. Marieb, Katja N. Hoehn
Publisher:Elaine N. Marieb, Katja N. Hoehn
Chapter1: The Human Body: An Orientation
Section: Chapter Questions
Problem 1RQ: The correct sequence of levels forming the structural hierarchy is A. (a) organ, organ system,...
icon
Related questions
Question

If you have a sample of unknown composition, a first step at analysis might be a determination of the masses of the atoms and molecules in the sample. A mass spectrometer to make such an analysis can take various forms, but for many years the best technique was to determine the masses of ionized atoms and molecules in a sample by observing their circular paths in a uniform magnetic field, as illustrated is shown. A sample to be analyzed is vaporized, then singly ionized. The ions are accelerated through an electric field, and ions of a known speed selected. These ions travel into a region of uniform magnetic field, where they follow circular paths. An exit slit allows ions that have followed a particular path to be counted by a detector, producing a record of the masses of the particles in the sample.

The moving ions can be thought of as a current loop, and it will produce its own magnetic field. The direction of this field at the center of the particles’ circular orbit is
A. In the same direction as the spectrometer’s magnetic field.
B. Opposite the direction of the spectrometer’s magnetic field.

 

1. Atoms are ionized and accelerated.
Ions of a particular velocity are
selected to enter the spectrometer.
2. Ions of different
masses follow paths
of different radii.
B
2r
Detector
3. Only ions of a particular mass reach the
exit slit and continue to the detector.
FIGURE P24.67
Transcribed Image Text:1. Atoms are ionized and accelerated. Ions of a particular velocity are selected to enter the spectrometer. 2. Ions of different masses follow paths of different radii. B 2r Detector 3. Only ions of a particular mass reach the exit slit and continue to the detector. FIGURE P24.67
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Acids and Bases
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Human Anatomy & Physiology (11th Edition)
Human Anatomy & Physiology (11th Edition)
Biology
ISBN:
9780134580999
Author:
Elaine N. Marieb, Katja N. Hoehn
Publisher:
PEARSON
Biology 2e
Biology 2e
Biology
ISBN:
9781947172517
Author:
Matthew Douglas, Jung Choi, Mary Ann Clark
Publisher:
OpenStax
Anatomy & Physiology
Anatomy & Physiology
Biology
ISBN:
9781259398629
Author:
McKinley, Michael P., O'loughlin, Valerie Dean, Bidle, Theresa Stouter
Publisher:
Mcgraw Hill Education,
Molecular Biology of the Cell (Sixth Edition)
Molecular Biology of the Cell (Sixth Edition)
Biology
ISBN:
9780815344322
Author:
Bruce Alberts, Alexander D. Johnson, Julian Lewis, David Morgan, Martin Raff, Keith Roberts, Peter Walter
Publisher:
W. W. Norton & Company
Laboratory Manual For Human Anatomy & Physiology
Laboratory Manual For Human Anatomy & Physiology
Biology
ISBN:
9781260159363
Author:
Martin, Terry R., Prentice-craver, Cynthia
Publisher:
McGraw-Hill Publishing Co.
Inquiry Into Life (16th Edition)
Inquiry Into Life (16th Edition)
Biology
ISBN:
9781260231700
Author:
Sylvia S. Mader, Michael Windelspecht
Publisher:
McGraw Hill Education