BPR130_CH09_Test

pdf

School

Wake Tech *

*We aren’t endorsed by this school

Course

BPR130

Subject

Mechanical Engineering

Date

Apr 3, 2024

Type

pdf

Pages

10

Uploaded by JudgeInternet11991

Report
Review Test Submission: Chapter 09 Test Question 1 1 out of 1 points A(n) __________ is a revised drawing that is prepared by a contractor at the conclusion of a project. Refer to the Veterinary Center Plans. Selected Answer: as-built Correct Answer: Evaluation Method Correct Answer Exact Match as-built Pattern Match (?i)as[\s-]built Question 2 1 out of 1 points The __________ establishes guidelines for accessibility to places of public accommodation and commercial facilities by individuals with disabilities. Refer to the Veterinary Center Plans. Selected Answer: Americans with Disabilities Act (ADA) Correct Answer: Americans with Disabilities Act (ADA) Question 3 1 out of 1 points The __________ Plan shows the connections of roof drains and surface drains into an integrated storm water Refer to the Veterinary Center Plans. Selected Answer: Grading and Utility Correct Answer: Evaluation Method Correct Answer Exact Match Grading and Utility Pattern Match (?i)Grading and Utility([\s-]Plan)? Question 4 1 out of 1 points A different gridline system is used on the Second Floor Plan as the Foundation Plan and the First Floor Plan. Refer to the Veterinary Center Plans. Selected Answer: False Correct Answer: False Question 5
1 out of 1 points Curbs and pavement for the parking area are shown on the __________ Plan. Refer to the Veterinary Center Plans. Selected Answer: Grading and Utility Correct Answer: Grading and Utility Question 6 1 out of 1 points Signage is shown on the exterior elevation drawings. Refer to the Veterinary Center Plans. Selected Answer: True Correct Answer: True Question 7 1 out of 1 points The Grading and Utility Plan includes both the concrete foundation work and the structural steel information for the project. Refer to the Veterinary Center Plans. Selected Answer: False Correct Answer: False Question 8 1 out of 1 points A(n) __________ is constructed near the southernmost skylight to divert water around the skylight and toward Refer to the Veterinary Center Plans. Selected Answer: cricket Correct Answer: Evaluation Method Correct Answer Exact Match cricket Question 9 1 out of 1 points A small tube steel __________ is installed at the entry to Exam #9 109 and Sprinkler (Spklr) 108. Refer to the Veterinary Center Plans. Selected Answer: pergola Correct Answer: Evaluation Method Correct Answer
Exact Match pergola Question 10 1 out of 1 points The upper roof area has a perimeter elevation of __________ above the finish floor. Refer to the Veterinary Center Plans. Selected Answer: 26'-0" Correct Answer: 26'-0" Question 11 0 out of 1 points There are a total of __________ light pole bases shown. Refer to the Veterinary Center Plans - Topographical Survey. Selected Answer: 5 Correct Answer: Evaluation Method Correct Answer Exact Match 3 Exact Match three Question 12 1 out of 1 points The highest surface elevation within the property boundaries is __________'. Refer to the Veterinary Center Plans - Topographical Survey. Selected Answer: 652 Correct Answer: 652 Question 13 1 out of 1 points The elevation of the benchmark on the north line of 55th Street is __________. Refer to the Veterinary Center Plans - Topographical Survey. Selected Answer: 651.71' Correct Answer: Evaluation Method Correct Answer Exact Match 651.71' Pattern Match (?i)651\.71('|\s?(ft|ft.|feet)) Question 14 1 out of 1 points
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
The amount of change in elevation of the concrete pad outside door 139b is __________. Refer to the Veterinary Center Plans - Sheet GU (Grading and Utility Plan). Selected Answer: .10' Correct Answer: Evaluation Method Correct Answer Exact Match 0.10' Pattern Match (?i)0?\.10?('|\s?(ft|ft.|feet)) Question 15 1 out of 1 points The change in elevation from the center of the tactile walking surface to door 100b at Vestibule 100 is ______ Refer to the Veterinary Center Plans - Sheet GU (Grading and Utility Plan). Selected Answer: 0.12' Correct Answer: Evaluation Method Correct Answer Exact Match 0.12' Pattern Match (?i)0?\.12('|\s?(ft|ft.|feet)) Question 16 1 out of 1 points The outdoor play area central drain is a __________. Refer to the Veterinary Center Plans - Sheet GU (Grading and Utility Plan). Selected Answer: 6" perforated pipe Correct Answer: 6" perforated pipe Question 17 1 out of 1 points Exam #2, #3, #4, and #5 all have identical interior dimensions. Refer to the Veterinary Center Plans - Sheet A-1.0 (First Floor Plan). Selected Answer: True Correct Answer: True Question 18 1 out of 1 points The depth of the countertop on the west side of Office 113 is __________. Refer to the Veterinary Center Plans - Sheet A-1.0 (First Floor Plan). Selected Answer: 1'-6"
Correct Answer: 1'-6" Question 19 1 out of 1 points The width of all the interior stairs shown on the First Floor Plan is __________. Refer to the Veterinary Center Plans - Sheet A-1.0 (First Floor Plan). Selected Answer: 4'0" Correct Answer: Evaluation Method Correct Answer Exact Match 4'-0" Pattern Match 4'([\s-]?0")? Pattern Match (?i)4\s?(ft|ft.|feet)([\s- ]0\s?(in|in.|inch|inches))? Pattern Match (?i)four\s(ft|ft.|feet)([\s- ]zero\s(in|in.|inch|inches))? Question 20 1 out of 1 points The two squares to the east of gridline G between gridlines 10 and 13 indicate locations for roof- mounted equipment. Refer to the Veterinary Center Plans - Sheet A-1.1 (Second Floor Plan). Selected Answer: False Correct Answer: False Question 21 1 out of 1 points There are no boarding facilities installed on the second floor above the first floor electrical room. Refer to the Veterinary Center Plans - Sheet A-1.1 (Second Floor Plan). Selected Answer: False Correct Answer: False Question 22 0 out of 1 points The distance from the outside wall of I.T. 213 to the window in Food 216 is __________. Refer to the Veterinary Center Plans - Sheet A-1.1 (Second Floor Plan). Selected Answer: 34'-8" Correct Answer: Evaluation Method Correct Answer Exact Match 34'-7" Pattern Match 34'[\s-]?7"
Pattern Match (?i)34\s?(ft|ft.|feet)[\s-]7\s?(in|in.|inch| Pattern Match (?i)thirty[\s-]four\s(ft|ft.|feet)[\s- ]seven\s(in|in.|inch|inches) Question 23 1 out of 1 points The elevation of the roof drains above Upper Level Boarding is __________. Refer to the Veterinary Center Plans - Sheet A-1.2 (Roof Plan). Selected Answer: 25'-6" Correct Answer: 25'-6" Question 24 1 out of 1 points The high point of the roof slope above the main waiting area is at the __________ side. Refer to the Veterinary Center Plans - Sheet A-1.2 (Roof Plan). Selected Answer: north Correct Answer: north Question 25 1 out of 1 points The spacing of the metal studs at the skylight opening is __________" O.C. Refer to the Veterinary Center Plans - Sheet A-1.2 (Roof Plan). Selected Answer: 16 Correct Answer: 16 Question 26 0 out of 1 points There is stone veneer shown on the north, south, east, and west exterior elevations. Refer to the Veterinary Center Plans - Sheet A-4.0 (Exterior Elevations). Selected Answer: False Correct Answer: True Question 27 1 out of 1 points The sloping roof over the Outdoor Play Yard is __________.
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
Refer to the Veterinary Center Plans - Sheet A-4.0 (Exterior Elevations). Selected Answer: prefinished metal Correct Answer: prefinished metal Question 28 1 out of 1 points An aluminum picket fence is installed outside of door 139b. Refer to the Veterinary Center Plans - Sheet A-4.0 (Exterior Elevations). Selected Answer: True Correct Answer: True Question 29 1 out of 1 points The height from the finished floor to the top of the steel at the south side of the reception area is __________. Refer to the Veterinary Center Plans - Sheet A-5.0 (Building Sections). Selected Answer: 21'-4" Correct Answer: Evaluation Method Correct Answer Exact Match 21'-4" Pattern Match 21'[\s-]?4" Pattern Match (?i)21\s?(ft|ft.|feet)[\s-]4\s?(in|in.|inch| Pattern Match (?i)twenty[\s-]one\s(ft|ft.|feet)[\s- ]four\s(in|in.|inch|inches) Question 30 1 out of 1 points The stairs above Boarding 139 have 3 stringers. Refer to the Veterinary Center Plans - Sheet A-5.0 (Building Sections). Selected Answer: True Correct Answer: True Question 31 1 out of 1 points There are no gutters on the north side of the building. Refer to the Veterinary Center Plans - Sheet A-5.0 (Building Sections). Selected Answer: True Correct Answer: True Question 32
0 out of 1 points The length, width, and depth of the steel column footings on either side of the vestibule are __________. Selected Answer: 2' x 2' x 4' Correct Answer: Evaluation Method Correct Answer Exact Match 3'-0" x 3'-0" x 1'-0" Pattern Match 3'([\s-]?0")?\s?(x|\*|by)\s?3'([\s-]?0")?\s?(x|\*|by) Pattern Match (?i)3\s?(ft|ft.|feet)([\s- ]0\s?(in|in.|inch|inches))?\s?(x|\*|by)\s?(?i)3\s?(ft ]0\s?(in|in.|inch|inches))?\s?(x|\*|by)\s?(?i)1\s?(ft ]0\s?(in|in.|inch|inches))? Pattern Match (?i)three\s(ft|ft.|feet)([\s- ]zero\s(in|in.|inch|inches))?\s?(x|\*|by)\s?(?i)three ]zero\s(in|in.|inch|inches))?\s?(x|\*|by)\s?(?i)one\ ]zero\s(in|in.|inch|inches))? Question 33 0 out of 1 points The width of the foundation wall under the south wall of the electrical room is __________. Refer to the Veterinary Center Plans - Sheet S-02 (Foundation Plan). Selected Answer: 2'-0" Correct Answer: 1'-4" Question 34 1 out of 1 points All laps in steel reinforcing shall be class __________ lap splices unless noted otherwise. Refer to the Veterinary Center Plans - Sheet S-02 (Foundation Plan). Selected Answer: B Correct Answer: Evaluation Method Correct Answer Exact Match B Question 35 1 out of 1 points The thickness of the concrete in the composite deck around the perimeter of the Indoor Yard/Boarding area is Refer to the Veterinary Center Plans - Sheet S-03 (2nd Floor and Lower Roof Framing Plans). Selected Answer: 2" Correct Answer: Evaluation Method Correct Answer
Exact Match 2" Pattern Match (?i)2("|\s?(in|in.|inch|inches))? Pattern Match (?i)two(\s(in|in.|inch|inches))? Question 36 1 out of 1 points The bar joists above the first floor exam rooms are __________ in height. Refer to the Veterinary Center Plans - Sheet S-03 (2nd Floor and Lower Roof Framing Plans). Selected Answer: 18" Correct Answer: Evaluation Method Correct Answer Exact Match 18" Pattern Match (?i)18("|\s?(in|in.|inch|inches))? Pattern Match (?i)eighteen(\s(in|in.|inch|inches))? Question 37 1 out of 1 points The wall on the east side of the reception area is built of __________. Refer to the Veterinary Center Plans - Sheet S-03 (2nd Floor and Lower Roof Framing Plans). Selected Answer: concrete masonry units Correct Answer: concrete masonry units Question 38 1 out of 1 points There is an 18" tall beam installed above the elevator shaft. Refer to the Veterinary Center Plans - Sheet S-04 (Roof Framing Plan). Selected Answer: False Correct Answer: False Question 39 1 out of 1 points The height of the bar joists over Boarding 217 is __________. Refer to the Veterinary Center Plans - Sheet S-04 (Roof Framing Plan). Selected Answer: 14" Correct Answer: Evaluation Method Correct Answer Exact Match 14" Pattern Match (?i)14("|\s?(in|in.|inch|inches))?
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
Pattern Match (?i)fourteen(\s(in|in.|inch|inches))? Question 40 0 out of 1 points The two story roof above Waiting 101 is finished at the outside edge with a __________ C channel. Refer to the Veterinary Center Plans - Sheet S-04 (Roof Framing Plan). Selected Answer: C6x8.2 Correct Answer: Evaluation Method Correct Answer Exact Match 6" Pattern Match (?i)6("|\s?(in|in.|inch|inches))? Pattern Match (?i)six(\s(in|in.|inch|inches))?