Question
28
Which
sequence
is
the
correct
order
of
steps
for
measuring
temperature
using
a
temporal
artery
thermometer?
°
L
Ensure
that
the
forehead
is
dry.
0
2.
Place
the
sensor
flush
on
the
patient’s
forehead.
°
3.
Press
the
red
scan
button
with
your
thumb.
0
4.
Lift
the
sensor
from
the
forehead
and
touch
the
sensor
to
the
skin
on
the
neck.
°
5.
Clean
the
sensor
with
an
alcohol
swab.
0
6.
Return
the
thermometer
to
the
charger.
Discover more documents: Sign up today!
Unlock a world of knowledge! Explore tailored content for a richer learning experience. Here's what you'll get:
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Related Questions
Select all the factors that affect the choice of sensor for level measurement? 0ptions:
direct or indirect
corrosiveness
liquid temperature and pressure
turbulence
particulate in a liquid
free flowing solids
volatility
single or continuous point measurements
arrow_forward
Programmable Logic Controller
arrow_forward
Testing oil pressure sensors usually
involves substituting the specified
in place of the sensor and
observing the reaction of the oil pressure
gauge.
Select one:
a. Pressure
b. Voltage
c. Resistance
d. None of the above
arrow_forward
Technician A says that many oil pressure
sensors are typically variable resistors that
change resistance based on pressure changes.
Technician B says that a sensor substitution
box can be used in place of the sensor while
observing the reaction of the oil pressure
gauge on the dash. Who is correct?
Select one:
a. Technician A
b. Technician B
c. Both A and B
d. Neither A nor B
arrow_forward
QUESTION 2
SOALAN 2
a) The DP Transmitter device is used to measure level as an inferential measurement. When
installing the DP Transmitter in an open tank at HP tapping point at 0%, the lower range
values (LRV) and upper range values (URV) for the transmitter must be determined in order
to properly register 0% at the LRV and 100% at the URV liquid level. By referring to Figure
2, calculate the calibrated range with specific gravity, SG is 1.1 and height, H of the tank is
100mm.
Peranti Pemancar DP digunakan untuk mengukur paras sebagai ukuran taabir. Apabila
memasang Pemancar DP di tangki yang terbuka di HP titik tirus pada 0%, nilai julat yang
lebih rendah (LRV) dan nilai julat atas (URV) untuk pemancar mesti ditentukan untuk
daftarkan betul pada 0% LRV dan 100% URV. Dengan merujuk Rajah 2, hitungkan julat
yang dikalibrasi dengan graviti spesifik, S.G adalah 1.1 dan ketinggian, H tangki adalah
100mm.
Tank open to
Atmosphere
Махт. Level
Liquid
DP Transmitter
Vented to
Atmosphere
Min.…
arrow_forward
How many auxiliary views are found on this print?
arrow_forward
Truncation errors are increased as the round-off errors are decreased.Group of answer choices True False
Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 29oC, 29.2oC, 29.3oC, 28.9oC, and 29.1oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is not accurate and not precise The thermometer is faulty. The thermometer is accurate and precise The thermometer is not accurate but precise.
Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 36oC, 35.6oC, 36oC, 37oC, and 36.2oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is accurate and precise. The thermometer is accurate but not precise. The…
arrow_forward
I need these 3 parts answered for a review activity.
arrow_forward
Please solve all four part
arrow_forward
Pls Comment on the use of layout and other elements in the washing machine control panel. If errors occur based on this layout, walk through the accident scenario. Suggest potential ways of improving the interface to avoid a similar problem occurring.
arrow_forward
SEE MORE QUESTIONS
Recommended textbooks for you
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Related Questions
- Select all the factors that affect the choice of sensor for level measurement? 0ptions: direct or indirect corrosiveness liquid temperature and pressure turbulence particulate in a liquid free flowing solids volatility single or continuous point measurementsarrow_forwardProgrammable Logic Controllerarrow_forwardTesting oil pressure sensors usually involves substituting the specified in place of the sensor and observing the reaction of the oil pressure gauge. Select one: a. Pressure b. Voltage c. Resistance d. None of the abovearrow_forward
- Technician A says that many oil pressure sensors are typically variable resistors that change resistance based on pressure changes. Technician B says that a sensor substitution box can be used in place of the sensor while observing the reaction of the oil pressure gauge on the dash. Who is correct? Select one: a. Technician A b. Technician B c. Both A and B d. Neither A nor Barrow_forwardQUESTION 2 SOALAN 2 a) The DP Transmitter device is used to measure level as an inferential measurement. When installing the DP Transmitter in an open tank at HP tapping point at 0%, the lower range values (LRV) and upper range values (URV) for the transmitter must be determined in order to properly register 0% at the LRV and 100% at the URV liquid level. By referring to Figure 2, calculate the calibrated range with specific gravity, SG is 1.1 and height, H of the tank is 100mm. Peranti Pemancar DP digunakan untuk mengukur paras sebagai ukuran taabir. Apabila memasang Pemancar DP di tangki yang terbuka di HP titik tirus pada 0%, nilai julat yang lebih rendah (LRV) dan nilai julat atas (URV) untuk pemancar mesti ditentukan untuk daftarkan betul pada 0% LRV dan 100% URV. Dengan merujuk Rajah 2, hitungkan julat yang dikalibrasi dengan graviti spesifik, S.G adalah 1.1 dan ketinggian, H tangki adalah 100mm. Tank open to Atmosphere Махт. Level Liquid DP Transmitter Vented to Atmosphere Min.…arrow_forwardHow many auxiliary views are found on this print?arrow_forward
- Truncation errors are increased as the round-off errors are decreased.Group of answer choices True False Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 29oC, 29.2oC, 29.3oC, 28.9oC, and 29.1oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is not accurate and not precise The thermometer is faulty. The thermometer is accurate and precise The thermometer is not accurate but precise. Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 36oC, 35.6oC, 36oC, 37oC, and 36.2oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is accurate and precise. The thermometer is accurate but not precise. The…arrow_forwardI need these 3 parts answered for a review activity.arrow_forwardPlease solve all four partarrow_forward