Solutions for Heating, Ventilation, and Air Conditioning: Analysis and Design
Problem 1.1P:
Convert the following quantities from English to SI units: a. 98 Btu/(hr-ft-F) b. 0.24 Btu/(lbm-F)...Problem 1.2P:
Convert the following quantities from SI to English units: a. 120 kPa b. 100W/(mC) c. 0.8W/(m2-C) d....Problem 1.3P:
A pump develops a total head of 50 ft of water under a given operating condition. What pressure is...Problem 1.4P:
A fan is observed to operate with a pressure difference of 4 in. of water. What is the pressure...Problem 1.5P:
The electric utility rate for a facility during the months of May through October is 4.5 cents per...Problem 1.6P:
For the business whose monthly electrical energy use in described in Problem 1-5, estimate the...Problem 1.7P:
Detmine the interest rate at which the project in Example 1-2 would become feasible. Do higher...Problem 1.8P:
How much could a company afford to spend on an HVAC system that would bring monthly savings of $1000...Problem 1.9P:
Make the following volume and mass flow rate calculations in SI units. (a) Water flowing at an...Problem 1.10P:
A room with dimensions of 31020m is estimated to have outdoor air brought in at an infiltration rate...Problem 1.11P:
Compute the heat transferred from water as it flows through a heat exchanger at a steady rate of 1...Problem 1.12P:
Air enters a heat exchanger at a rate of 5000 cubic feet per minute at a temperature of 50 F and...Problem 1.13P:
Water flowing at a rate of 1.5 kg/s through a heat exchanger heats air from 20 C to 30 C flowing at...Problem 1.14P:
Air at a mean temperature of 50 F flows over a thin-wall 1-in. O.D. tube, 10 feet in length, which...Problem 1.15P:
Repeat Problem 1-10 for air at 10 C, a tube with diameter 25 mm, a stream pressure of 101 kPa, and a...Problem 1.16P:
Air at 1 atm and 76 F is flowing at the rate of 5000 cfm. At what rate must energy be removed, in...Problem 1.17P:
Air flowing at the rate of 1000 cfm and with a temperature of 80 F is mixed with 600 cfm of air at...Problem 1.18P:
A chiller is providing 5 tons of cooling to an air handler by cooling water transfer between the two...Problem 1.19P:
Air is delivered to a room at 58 F and the same amount of air is removed from the room at 76 F in...Problem 1.20P:
A chiller is to pro;ide 12 tons of cooling to a chilled water stream. That must the flow rate...Problem 1.21P:
Air is being rnished to a 30-ft by 40-ft by 12-ft room at the rate of 600 cfm and mixes thoroughly...Problem 1.22P:
If cold outside air at 20 F is leaking into a 20-ft by 30-ft by 10-ft room where the heating system...Problem 1.23P:
A Btu-meter is a device that measures water flow rate and the temperature difference between the...Sample Solutions for this Textbook
We offer sample solutions for Heating, Ventilation, and Air Conditioning: Analysis and Design homework problems. See examples below:
More Editions of This Book
Corresponding editions of this textbook are also available below:
Heating Ventilating and Air Conditioning: Analysis and Design
6th Edition
ISBN: 9780471470151
HEATING, VENTILATING,+AC ANAL...EBOOK>I<
6th Edition
ISBN: 2819480255750
Heating, Ventilating And Air Conditioning Analysis And Design
6th Edition
ISBN: 9788126531875
Heating, Ventilating, And Air Conditioning: Analysis And Design
3rd Edition
ISBN: 9780471637578
Heating, Ventilating And Air Conditioning: Analysis And Design
2nd Edition
ISBN: 9780471082590
Heating, Ventilating And Air Conditioning
2nd Edition
ISBN: 9780471021247
Heating, Ventilating, And Air Conditioning: Analysis And Design
4th Edition
ISBN: 9780471581079
Heating, Ventitating & Air Conditioning - Analysis & Design 4e Sol T/a
4th Edition
ISBN: 9780471309000
Heating, Ventilating, and Air Conditioning: Analysis and Design
5th Edition
ISBN: 9780471350989
Related Mechanical Engineering Textbooks with Solutions
Still sussing out bartleby
Check out a sample textbook solution.