To determine

(a)

To select the W?X? satisfactory shape using LFRD method.

Expert Solution
Check Mark

Answer to Problem 9.8.7P

The beam W24×76 is safe.

Explanation of Solution

Given:

Thickness of slab, t = 5.0 inches, spacing = 7.0 ft, span length, L = 30 feet, yield stress = 50 Ksi

Construction load = 20 psf, and live load = 800 psf.

The value of fc'=4ksi.

Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card, Chapter 9, Problem 9.8.7P

Calculation:

Using LRFD method, we select a suitable shape that will satisfy the given conditions:

Calculate the loads on the beam as follows:

After curing we have,

WS=t12(150)Lp

Where, t is the thickness of the slab, WS the self-weight of slab on one beam, Lp is the distance

between two adjacent beams.

WS=t12(150)Lp

WS=5.012(150)×7.0WS=437.50lbft.

The dead load on the beam after the concrete has cured is:

WD=WSWD=WS=437.50lbft

Calculate the live load on the beam using the following equation:

WD=WSLLP

Where, WSL is the construction load on the beam.

WD=WSLLPWD=800.00psf×7.0ftWD=5600.00lbft.

Calculate the factored uniformly distributed load after curing has completed by following formula:

Wu=((1.2×WD)+(1.6×WL))Kipsft

Where, WD is the uniformly distributed dead load on the beam and WL is the applied live load on the beam.

Substitute the values, we get

Wu=((1.2×WD)+(1.6×WL))KipsftWu=((1.2×0.4375)+(1.6×5.600))KipsftWu=0.525Kipsft+8.960KipsftWu=9.485Kipsft

Calculate the bending moment on the beam;

Mu=wuLAB28

Where, Mu is the bending moment and LAB is the length of the beam.

Mu=wuLAB28Mu=(9.485×302)8Kipsftft2Mu=1067.06Kips-ft.

Try for W24×76, we have from the manual of ASIC

DesignationImperial (in x lb/ft) Depthh (in) Widthw (in) Web Thicknesstw (in) Flange Thicknesstf (in) Sectional Area (in2) Weight (lbf/ft) Static Parameters
Moment of Inertia Elastic Section Modulus
Ix (in4) Iy (in4) Sx (in3) Sy (in3)
W 24 x 76 23.9 9 0.440 0.680 22.4 76 2100 82.5 176 18.4

Qn=394Kips.ft

Calculate the distance of the plastic neutral axis from the top of the slab as follows:

CC=0.85fC'bt

Where, b is the width of the concrete slab, t is the thickness of the concrete beam, fC' is the compressive strength of the concrete and a is the distance of neutral axis from the top of the slab.

The effective flange width is as follows;

b=Min(12LABt,12Lp)b=Min(12×304,12×7.0)b=Min(90in,84in)b=84in.

Substitute the values, we have

0.85fC'ab=C

0.85×4Ksi×a×84=394.00kipsa=394.00kips0.85×4Ksi×84a=1.3795ina=1.380in

Compute the value of Y as shown below:

y=ta2y=5.0in1.380in2y=5.0in0.690in.y=4.310in.

From the manual the value of nominal flexural strength of the beam

ϕb×Mn=1102Kips.ft

Comparing the values of (ϕbMn) and Mu, we have

1067.00Kips-ft<1102.00Kips.ftMu<(ϕbMn)

Thus, the beam is satisfactory excluding its self-weight.

Now for including the weight of the beam, we have

Calculate the factored uniformly distributed load after curing has completed by following formula:

Where, WS is the self-weight of the beam, WD is the uniformly distributed dead load on the beam and WL is the applied live load on the beam.

Substitute the values, we get

Wu=(1.2×(WS+WD)+(1.6×WL))KipsftWu=((1.2(0.4375psf+0.076psf))+(1.6(5.60psf)))KipsftWu=0.6162Kipsft+8.960KipsftWu=9.5762Kipsft

Calculate the maximum bending moment on the beam;

Mu=wuL28

Where, Mu is the maximum bending moment and L is the length of the beam.

Mu=wuL28Mu=(9.5762×302)8Kipsftft2Mu=1077.323Kips-ft.

Check the flexural strength of the beam including its weight.

1077.00Kips-ft<1102.00Kips.ftMul<(ϕbMn)

Thus, the beam is satisfactory including its self-weight.

Check for the shear:

Checking the value of nominal value of shear strength of W24×76 from the AISC Manual.

ϕvVn=315.00kips

Where, ϕvVn is the nominal shear strength.

The maximum shear force is as following for the above conditions:

Vn=wuL2

Substitute the values, we have

Vn=wuL2Vn=9.576kips ft-1×30ft2Vn=143.00kips.

Now comparing the two we have

Vn=143.00kips<ϕvVn=315.00kips

Therefore, the beam is safe in shear and we can use W24×76.

Calculate the factored uniformly distributed load before curing has completed by following formula:

Wu=((1.2×WD)+(1.6×WL))Kipsft

Where, WD is the uniformly distributed dead load on the beam and WL is the applied live load on the beam.

WS=t12(150)Lp

Where, t is the thickness of the slab, WS the self-weight of slab on one beam, Lp is the distance

between two adjacent beams.

WS=t12(150)Lp

WS=5.012(150)×7.0WS=437.50lbft.

The dead load on the beam before the concrete has cured is:

WD=WS+WWD=437.50lbft+76.00lbftWD=513.50lbft

Calculate the live load on the beam using the following equation:

WD=WSLLP

Where, WSL is the construction load on the beam.

WD=WSLLPWD=20.00psf×7.0ftWD=140.00lbft.

Substitute the values, we get

Wu=((1.2×WD)+(1.6×WL))KipsftWu=((1.2×0.5135)+(1.6×0.140))KipsftWu=0.6162Kipsft+0.224KipsftWu=0.8402Kipsft

Calculate the maximum bending moment on the beam;

Mu=wuL28

Where, Mu is the maximum bending moment and L is the length of the beam.

Mu=wuL28Mu=(0.8402×302)8Kipsftft2Mu=94.523Kips-ft.

Check for the value of nominal flexural strength, the flexural strength of the beam before curing is

ϕb×Mn=ϕb×MP=315.00Kips.ft

Comparing the values of (ϕbMn) and Mu, We have

94.00Kips-ft<315.00Kips.ftMu<(ϕbMn)

Therefore, the beam is satisfactory before the curing has completed.

Now calculating the maximum allowable live load deflection from the given beam using the formula as:

ΔMax=L360

Substitute the values, we have

ΔMax=L360ΔMax=30×12360ΔMax=360360inΔMax=1.00in

We have the value of lower bound moment of inertia for the given condition as follows:

Itb=3642in4

Calculating the total load on the beam using the following :

Δ=5wLL4384EItb

Where, Δ is the maximum deflection, L is the length of the beam, W is the uniformly distributed load on beam, E is the modulus of elasticity and I is the moment of inertia.

Δ=5wLL4384EItbΔ=5×5.60Kips.ft×(30×12)4384×12×29000Ksi×3642in4Δ=0.9663in.

Now by comparing the values, we have

ΔMax=1.00in>Δ=0.9663in.

Conclusion:

Hence, the beam W24×76 is safe.

To determine

(b)

Use ASD method to select the W?X? satisfactory shape.

Expert Solution
Check Mark

Answer to Problem 9.8.7P

The beam W24×76 is safe.

Explanation of Solution

Calculation:

Now, we will use allowable stress design

Calculate the loads on the beam as follows:

After curing we have,

WS=t12(150)Lp

Where, t is the thickness of the slab, WS the self-weight of slab on one beam, Lp is the distance

between two adjacent beams.

WS=t12(150)Lp

WS=5.012(150)×7.0WS=437.50lbft.

The dead load on the beam after the concrete has cured is:

WD=WSWD=WS=437.50lbft

Calculate the live load on the beam using the following equation:

WL=WSLLP

Where, WSL is the construction load on the beam

WL=WSLLPWL=800.00psf×7.0ftWL=5600.00lbft.

Calculate the allowable uniformly distributed load after curing has completed by following formula:

Wa=(WD+WL)Kipsft

Where, WD is the uniformly distributed dead load on the beam and WL is the applied live load on the beam.

Substitute the values, we get

Wa=(WD+WL)KipsftWu=0.4375Kipsft+5.60KipsftWu=6.0375Kipsft

Calculate the bending moment on the beam;

Mu=wuLAB28

Where, Mu is the bending moment and LAB is the length of the beam.

Mu=wuLAB28Mu=(6.0375×302)8Kipsftft2Mu=679.22Kips-ft.

Compute the value of Y, which is the distance from the top of steel shape to compressive force

in concrete and is shown below:

y=ta2y=5.0in1.00in2y=5.0in0.50in.y=4.50in.

Try for W24×76, we have from the manual of ASIC

Qn=335.00Kips.ft

Calculate the distance of the plastic neutral axis from the top of the slab as follows:

CC=0.85fC'bt

Where, b is the width of the concrete slab, t is the thickness of the concrete beam, fC' is the compressive strength of the concrete and a is the distance of neutral axis from the top of the slab.

The effective flange width is as follows;

b=Min(12LABt,12Lp)b=Min(12×304,12×7.0)b=Min(90in,84in)b=84in.

Substitute the values, we have

0.85fC'ab=C

0.85×4Ksi×a×84=335.00kipsa=335.00kips0.85×4Ksi×84a=1.173in

Compute the value of Y as shown below:

y=ta2y=5.0in1.173in2y=5.0in0.5865in.y=4.414in.

From the table 3-19 of the ASIC manual:

Trying for W21×48

Check whether the section is safe in flexure if the self -weight is excluded

MnΩb=732.00ft-kips

Where, MnΩb is the allowable flexural strength.

Now comparing the values of Ma and MnΩb

Substitute the values, we have

MnΩb=732.00ft-kips  >  Mu=679.00ft-kips

Therefore, the section is safe in flexure if the self -weight is excluded.

Let’s check for the beam weight :

Calculation of the maximum bending moment as follows:

Mal=Ma+wsL28

Substitute the values, we get

Mal=Ma+wsL28Mal=679.00ft-kips+0.076kips ft-1×(30ft)28Mal=679.00ft-kips+8.55ft-kipsMal=687.55ft-kips

Now check for the flexural strength including the beam weight:

Comparing the values of maximum bending moment and the nominal flexural strength as follows:

Mal=687.55ft-kips<MnΩb=732.00ft-kips

Therefore, the section is safe in flexure including the self-weight of the beam.

Check for the shear:

Checking the value of nominal value of shear strength of W24×76 from the AISC Manual.

VnΩb=210.00kips

Where, VnΩb is the nominal shear strength.

The maximum shear force is as following for the above conditions:

Va=waL2

Substitute the values, we have

Va=waL2Va=6.114kips ft-1×30ft2Va=91.71kips

Now comparing the two we have

Va=91.71kips<VnΩb=210.00kips

Therefore, the beam is safe in shear and we can use W24×76.

Calculate the loads on the beam as follows:

Before curing we have,

WS=t12(150)Lp

Where, t is the thickness of the slab, WS the self-weight of slab on one beam, Lp is the distance

between two adjacent beams.

WS=t12(150)Lp

WS=5.012(150)×7.0WS=437.50lbft.

The dead load on the beam before the concrete has cured is:

WD=WS+WWD=437.50lbft+76.00lbftWD=513.50lbft

Calculate the live load on the beam using the following equation:

WD=WSLLP

Where, WSL is the construction load on the beam.

WD=WSLLPWD=20.00psf×7.0ftWD=140.00lbft.

Substitute the values, we get

Wu=(WD+WL)KipsftWu=0.5135Kipsft+0.140KipsftWu=0.6535Kipsft

Calculate the maximum bending moment on the beam;

Mu=wuL28

Where, Mu is the maximum bending moment and L is the length of the beam.

Mu=wuL28Mu=(0.6535×302)8Kipsftft2Mu=73.52Kips-ft.

Checking the value of nominal flexural strength of W- section from the ZX table of the ASIC manual:

Check whether the section is safe in flexure if the self -weight is excluded

MnΩb=MPΩb=499.00ft-kips

Where, MnΩb is the allowable flexural strength and MPΩb is the plastic moment.

Now comparing the values of Ma and MnΩb

Substitute the values, we have

MnΩb=499.00ft-kips  >  Ma=73.52ft-kips

Therefore, the section is safe in before the curing of concrete.

Now calculating the maximum allowable live load deflection from the given beam using the formula as:

ΔMax=L360

Substitute the values, we have

ΔMax=L360ΔMax=30×12360ΔMax=360360inΔMax=1.00in

We have the value of lower bound moment of inertia for the given condition as follows:

Itb=3642in4

Calculating the total load on the beam using the following :

Δ=5wLL4384EItb

Where, Δ is the maximum deflection, L is the length of the beam, W is the uniformly distributed load on beam, E is the modulus of elasticity and I is the moment of inertia.

Δ=5wLL4384EItbΔ=5×5.60Kips.ft×(30×12)4384×12×29000Ksi×3642in4Δ=0.9663in.

Now by comparing the values, we have

ΔMax=1.00in>Δ=0.9663in.

Conclusion:

Hence, the beam W24×76 is safe.

To determine

(c)

Selecting the stud anchors.

Expert Solution
Check Mark

Answer to Problem 9.8.7P

We will use 54 Studs with 58inch×212inch dimension, with the spacing of 6.50in.

Explanation of Solution

Calculation:

From AISC specifications, compute the maximum stud diameter using the equation:

dmax=2.5tf

Where, tf id the flange thickness and dmax is the maximum diameter.

Substitute the values, we get

dmax=2.5tfdmax=2.5×0.680indmax=1.70in

Try for the studs of size 58in×212in studs.

From table 3-21 for lightweight concrete take one stud at each of the beam position.

Qn=15.00Kips

The number of studs for half beam can be found as follows:

N1=QnQn.

Substitute the values, we have

N1=QnQn.Qn=VN1=394.00Kips15.00Kips.N1=26.27N127

Compute the number of studs as follows:

N=2N1.

Substitute the value of N1, we have

N=2N1.N=2×27N=54

Calculate the spacing of the studs as follows:

Compute the minimum longitudinal spacing for studs using the equation

St,min=6d

Where, St,min is the minimum longitudinal spacing for studs and d is the diameter of the stud.

Substitute the values

St,min=6dSt,min=6×58inSt,min=3.75in

Compute the minimum transverse spacing for studs using the equation

St,min=4d

Where, St,min is the minimum transverse spacing for studs and d is the diameter of the stud.

Substitute the values

St,min=4dSt,min=4×58inSt,min=2.50in

Compute the maximum longitudinal spacing for studs using the equation

St,max=8t

Where, St,max is the minimum transverse spacing for studs and d is the thickness of the concrete slab.

Substitute the values

St,max=8tSt,max=8×5inSt,max=40in

But the upper limit of the spacing is 36 inches.

Calculate the require spacing for one stud at each of the section:

S=LN

Substitute the values, we have

S=30×1254S=6.670in.

Conclusion:

Therefore, we will use 54 Studs with 58inch×212inch dimension, with the spacing of 6.50in.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
K Course Code CE181303 Course Title Hours per week L-T-P Credit C Fluid Mechanics 3-1-0 MODULE 1: Fluid Properties: Fluid-definition, types; physical properties of fluid-density, specific weight, specific volume, specific gravity, viscosity- Newton's law of viscosity, surface tension, compressibility of fluids, capillarity. MODULE 2: Fluid Statics: Hydrostatic pressure, pressure height relationship, absolute and gauge pressure, measurement of pressure-manometer, pressure on submerged plane and curved surfaces, centre of pressure; buoyancy, equilibrium of floating bodies, metacentre; fluid mass subjected to accelerations. MODULE 3: Fluid Kinematics: Types of motion- steady and unsteady flow, uniform and no uniform flow, laminar and turbulent flow, and path lines, stream tube, stream function compressible and incompressible flow, one, two & three dimensional flow; stream lines, streak lines and velocity potential, flow net and its drawing: free and forced vortex. MODITE Q. A closed…
H.W: For the tank shown in figure below, Find The amount of salt in the tank at any time. Ans: x = 2(100+t) 1500000 (100 + t)² Qin = 3 L/min Cin = 2 N/L V = 100 L Xo=50N Qout = 2 L/min Cout? 33
- Find reactions and draw Shear and Bending Moment Diagram. 30 N 15 N/m D B A 2 m 1 m 2 mm
Knowledge Booster
Background pattern image
Civil Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning