Power System Analysis and Design (MindTap Course List)
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
bartleby

Concept explainers

Question
Book Icon
Chapter 9, Problem 9.2P
To determine

The Thevenin equivalent for each sequence network as viewed from the fault bus.

Blurred answer
Students have asked these similar questions
b) A fault occurs at bus 3 of the network shown in Figure Q4. Pre-fault nodal voltages throughout the network are of 1 p.u. and the impedance of the electric arc is neglected. Sequence impedance parameters of the generator, transmission lines, transformer and load are given in Figure Q4. V₁ = 120° p.u. V₂ = 120° p.u. V₂ = 1/0° p.u. V₂= 120° p.u. jXj0.1 p.u. JX2) 0.1 p.u. jX0j0.15 p.u. jXn-j0.2 p.u. 1 JX(2)-j0.2 p.u. 2 jX)=j0.25 p.u. JX20-10.15 p.u. jXa(z)-j0.2 p.u. 4 jX2(0)=j0.2 p.u. jXT(1) j0.1 p.u. jXT(2)=j0.15 p.u. jXT(0)=j0.1 p.u. Figure Q4. Circuit for problem 4b). = jXj0.1 p.u. j0.1 p.u. - JX(2) JXL(0) 10.1 p.u. = (i) Assuming a balanced excitation, draw the positive, negative and zero sequence Thévenin equivalent circuits as seen from bus 3. (ii) Determine the positive sequence fault current for the case when a three- phase-to-ground fault occurs at bus 3 of the network. (iii) Determine the short-circuit fault current for the case when a one-phase- to-ground fault occurs at bus…
b) A fault occurs at bus 2 of the network shown in Figure Q3. Pre-fault nodal voltages throughout the network are of 1 p.u. and the impedance of the electric arc is neglected. Sequence impedance parameters of the generator, transmission lines, and transformer are given in Figure Q3, where X and Y are the last two digits of your student number. JX20 /0.1X p.u. jXa2) 0.1X p.u. JX20 j0.2Y p.u. V,= 120° p.u. V, 120° p.u. V, 120° p.u. jX4-70.2X p.u. jX2 j0.2X p.u. jX o 0.2Y p.u. jXncay J0.25 p.u. jXna J0.25 p.u. 3 jXno0.3 p.u. jXTu) /0.2Y p.u. jXra j0.2Y p.u. - j0.2Y p.u. Xp-10.1X p.u. jXa j0.1X p.u. jXp0)- j0.05 p.u. 0 Figure Q3. Circuit for problem 3b). For example, if your student number is c1700123, then: jXac1) = j0.22 p.u., jXac2) = j0.22 p.u., and jXaco) = j0.23 p. u. X-2 Y=8 (iv) Determine the short-circuit fault current for the case when a phase-to- phase fault occurs at bus 2.
Q2 Figure Q2 shows a single line diagram of a power system and the associated data of this system are given in Table Q2. The pre-fault load current and A-Y transformer phase shift are neglected. (a) (b) If a Single Line-to-Ground (S-L-G) fault occurs at Bus 5 and the pre-fault voltage is 1.0 pu, calculate the subtransient fault current in Ampere. (c) (d) (e) Using base of 100 MVA and 11 kV at generator G₁, construct the positive sequence, negative sequence and zero sequence networks with their corresponding component values indicated. G₁ Recalculate (b) if the neutral on HV side of T3 is solidly grounded. Repeat part (b) with Line-to-line (L-L) fault. What will happen to L-L fault current in (d) if the neutral on the HV side of T3 is solidly grounded? Bus 1 T₁ Bus 4 Line 1 Line 2 Figure Q2 Bus 5 T2 T3 Bus 2 Bus 3 G₂ G3
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Text book image
Electric Motor Control
Electrical Engineering
ISBN:9781133702818
Author:Herman
Publisher:CENGAGE L