Sustainable Energy
2nd Edition
ISBN: 9781337551663
Author: DUNLAP, Richard A.
Publisher: Cengage,
expand_more
expand_more
format_list_bulleted
Question
Chapter 9, Problem 13P
To determine
Find the maximum acceptable installation cost.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The annual average insolation for a fixed solar panel in
city A is 350 W/m2. On the other hand, city B has a figure
of 300 W/m?. For both locations, the solar panel has the
capability to convert 17% of the incident energy into
electricity. Average annual electricity in City A is 13 000
kWh with an average cost of $0.4/kWh, while in city B, it
is 10 000 kWh at a cost of $0.75/kWh.
For City A,
a. Determine the area of the solar panel needed in order
to suffice the average electrical needs of a residence.
b. Determine the area of the solar panel needed in order
to suffice the average electrical needs of a residence in
City B.
c. Determine the price per square meter of solar panel in
City A if the device has a lifetime of 20 years. Assume
that the electricity costs are constant throughout the
period.
d. Determine the price per square meter of solar panel in
City B if the device has a lifetime of 20 years. Assume
that the electricity costs are constant throughout the
period.
On a summer day, the mean solar irradiance received at a lake was 500 W/m^ 2 over 25 days (consider the day length to be 8 hours). If 80% of the energy is used to vaporize water, how large could the depth of evaporation be?
Q1: What is the primary process of converting solar energy
into other form of energy,
explain and give an example of each one of them?
Q2: Determine the Sun's altitude angle , azimuth angle, and
zenith angle at 5.00 P.M on
December 15, 2017 for a location at 24.85° N latitude.
Q3: Compare the power generated by the two shown systems
1 and 2, if each turbine have
air velocity in that area was V= 5 m/sec and the air density
p=1.19 kg/m³m while in system 2 to increase the air velocity
we uses a truncated cone of area ration A1/A2=4.
blades 5 m length, while the
Knowledge Booster
Similar questions
- RENEWABLE ENERGY IN CONSTRUCTIONarrow_forwardA 2 x 2 m flat plate solar collector for domestic hot water heating is shown in the figure. The incident solar radiation on the glass cover, which transmits 90% of the incident flux, is 750 W/m2. Water flows through the tubes soldered to the backside of the absorber plate, entering at a temperature of 25°C. The temperature of the glass cover is 27°C, and it radiates heat with an emissivity of 0.92 to the sky at –50°C. Additionally, the glass cover losses heat by convection to air at 20°C flowing over its surface at 30 km/h. Assume that the radiation heat transfer between the absorber plate and glass cover and the heat transfer through the back and sides of the collector is negligible.arrow_forwardFor a building located in Madrid, Spain with annual heating degree-days (dd) of 4654, a heating load (heat loss) of 30,000 kj/h, and a design temperature difference of 30° C (20° C indoor), estimate the annual energy consumption. If the building is heated with a furnace with an efficiency of 92%, how muchgas is burned to keep the home at 20° C? State your assumptions.arrow_forward
- Please help solve both for my homework. Due soonarrow_forwardWhen 1 cu ft of natural gas is burned, 1,050 Btu of heat are produced. In oneday, a building uses 761,250 Btu of heat. How many cubic feet of gas areburned?arrow_forwardReplacing incandescent lights with energy-efficient fluorescent lights can reduce the lighting energy consumption to one-fourth of what it was before. The energy consumed by the lamps is eventually converted to heat, and thus switching to energy-efficient lighting also reduces the cooling load in summer but increases the heating load in winter. Consider a building that is heated by a natural gas furnace with an efficiency of 80 percent and cooled by an air conditioner with a COP of 3.5. If electricity costs $0.12/kWh and natural gas costs $1.40/therm (1 therm = 105,500 kJ), determine if efficient lighting will increase or decrease the total energy cost of the building (a) in summer and (b) in winter.arrow_forward
- ENVIRONMENTAL ENGINEERING a). Explain the harmful or beneficial effects of Ground Level Ozone and Stratospheric Ozone. b). Describe the photochemical reaction for the formation of Ozone. Then, explain how CFC as a base atmospheric pollutant can cause the catalytic destruction of Ozone and the subsequent stabilization of chlorine. c). Compare the Traction Battery in a conventional Hybrid Electric Vehicle (HEV) with the batteries in a Plug-In Hybrid Electric Vehicle (PHEV) and then explain the possible emissions shift that may arise from PHEV use. d). Explain three applicable methods of Particulate Control using gas-cleaning devices.arrow_forwardA point source emits 200 radiant watts and has a luminous efficacy of 120 lumens/watt. Itsspatial distribution is spherically uniform. state any assumptions, check answer w bold text. a) What is the luminous intensity of this source? 1910 cdb) What is the average illuminance on a unit sphere centered around the point source? 6000/pii lx or fcc) What is the illuminance at point p at the center of circular surface A? 212 Ixd) If surface A has a radius of 2 m, what is the illuminance at point q? 122 lxf) what is the total number of lumens incident onto surface a? ~2015lmg) The total reflectance of surface A is 0.50. What is the average exitance of surface A? 80 Im/m2arrow_forwardConsider a 400-MW, 32 percent efficient coal-fired power plant that uses cooling water withdrawn from a nearby river (with an upstream flow of 10-m3/s and temperature 20 °C) to take care of waste heat. The heat content of the coal is 8,000 Btu/lb, the carbon content is 60% by mass, and the sulfur content is 2% by mass. How much electricity (in kWh/yr) would the plant produce each year? How many pounds per hour of coal would need to be burned at the plant? Estimate the annual carbon emissions from the plant (in metric tons C/year). If the cooling water is only allowed to rise in temperature by 10 °C, what flow rate (in m3/s) from the stream would be required? What would be the river temperature if all the waste heat was transferred to the river water assuming no heat losses during transfer? Estimate the hourly SO2 emissions (in kg/h) from the plant assuming that all the sulfur is oxidized to SO2 during combustion.arrow_forward
- Take a 4,000 G.S.F. home from 8290 CFH to 1409 CFH in a climate with 4246 HDD. What are the savings? Give your answer in Btus of heating energyarrow_forwardQuestion 2. A coal fired power station requires an ESP for dust removal from the flue gas. The influent flu gas has a concentration of 5200 mg/m3 of dust particles and a flow rate of 150 m3/s. The smallest particles in the gas stream are 1.5 um in diameter, and all particles have a dielectric constant of 5.5. The emission standard is 50 mg/m3. Assume a plate-to-plate spacing of 30 cm and an applied voltage of 15,000 volts. Each plate is 20 m long and 15 m high. Estimate –a) The particle drift velocityb) The required collection-plate area and number of plates required.Assume – Standard temperature and pressure.arrow_forward2. Consider the system described in the news: at night, when there is energy left, water is pumped from a large lake to a reservoir at 80 m above the lake level. During the day, this water is used to generate energy in a turbine located 80 m below the elevated reservoir. Considering that the water flow is always 5000 liters/s (both at the inlet of the reservoir and at the outlet) and that the pump and turbine efficiencies are 70%, what is the power (in kW) required by the pump and the power (in kW) recovered in the turbine. Data: The pipe diameter is always the same along the system (d = 0.5 m); g = 10 m/s2; γ = 9810 N/m3. Matter transport phenomena; Please make it typeable as handwriting interferes with understandingarrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Sustainable EnergyCivil EngineeringISBN:9781133108689Author:Richard A. DunlapPublisher:Cengage LearningEngineering Fundamentals: An Introduction to Engi...Civil EngineeringISBN:9781305084766Author:Saeed MoaveniPublisher:Cengage Learning
Sustainable Energy
Civil Engineering
ISBN:9781133108689
Author:Richard A. Dunlap
Publisher:Cengage Learning
Engineering Fundamentals: An Introduction to Engi...
Civil Engineering
ISBN:9781305084766
Author:Saeed Moaveni
Publisher:Cengage Learning