
(a)
The required diameter of group

Answer to Problem 8.2.7P
The required diameter of the bolt by elastic analysis using LRFD is
Explanation of Solution
Given data:
The live load is
The dead load is
Concept Used:
Write the equation of nominal bolt area.
Here, the diameter of bolt is
Calculation:
Write the equation to calculate the factored load for LRFD.
Here, the dead load is
Substitute
Determine the centroid with respect to the lower left bolt.
Write the equation to calculate the distance of centroid in
Here, the number of bolts is
Substitute the values in Equation (III).
Write the equation to calculate the distance of the centroid in
Substitute the values in Equation (IV).
Write the expression to calculate the load applied in the
Here, the total load is
Substitute
Write the expression to calculate the load applied in the
Here, the and load component in
Substitute
Write the equation to calculate the horizontal direct shear component.
Here, the load in
Substitute
Write the equation to calculate the vertical direct shear component.
Here, the load in
Substitute
Calculate the horizontal and vertical components of loads due to eccentricity.
Calculate the distance of the load from centroid of connection.
Here, the eccentricity in
Write the expression for the moment for
Here, moment generated is
Substitute
Write the expression for the moment for
Here, moment generated is
Substitute
Write the expression for the moment for
Here, the total moment generated is
Substitute
Write the equation to calculate the total fastener force.
Here, the total fastener force is
Write the equation to calculate the
Here, the horizontal direct shear component is
Write the equation to calculate the
Here, the vertical direct shear component is
The top right bolt is critical, thus check for its safety.
Calculate the distance of the bolt from the centroid.
Here, the distance of the top right bolt from the centroid in the x and y directions are
Write the equation to calculate the load coming on the critical bolt in x direction due to eccentricity.
Substitute
Write the equation to calculate the load coming on critical bolt in y direction due to eccentricity.
Substitute
Calculate the
Substitute
Calculate the
Substitute
Calculate the total fastener force.
Substitute
Check the safety for the bottom right bolt.
Calculate the distance of the bolt from the centroid.
Calculate the load coming on the critical bolt in x direction due to eccentricity.
Substitute
Calculate the load coming on critical bolt in y direction due to eccentricity.
Substitute
Calculate the
Substitute
Calculate the
Substitute
Calculate the total fastener force.
Substitute
Therefore, the total shear force in the fastener is
Write the equation to calculate the nominal shear capacity of bolt.
Here, the nominal shear capacity is
Substitute
Calculate the diameter of bolt.
Substitute
Therefore, adopt the bolt diameter of
Check for safety:
Write the equation to calculate the bearing deformation strength of the bolt.
Here, the bearing deformation strength is
Assume A36 steel and the value of
Assume the thickness of the plate is
Calculate the bearing deformation strength of bolt.
Substitute
Write the equation to calculate the tear-out strength of inner bolt.
Here, the tear-out strength of inner bolt is
Write the equation to calculate the clear distance for edge bolt.
Here, the bolt edge distance is
Write the equation to calculate the hole diameter.
Calculate the clear distance for edge bolt.
Substitute
Calculate the tear-out strength of inner bolt.
Substitute
Write the equation to calculate the tear-out strength of edge bolt.
Here, the tear-out strength of edge bolt is
Write the equation to calculate the clear distance for edge bolt.
Here, the spacing between bolts is
Substitute
Calculate the tear-out strength of edge bolt.
Substitute
The minimum of Equations (XXII), (XIX) and (XVIII) is the value of
Calculate the design of strength of bolt by substituting
The strength is greater than the design strength.
Therefore, adopt
Conclusion:
Thus, the size of bolt is
(b)
The size of bolt by elastic analysis using ASD.

Answer to Problem 8.2.7P
The size of bolt by elastic analysis using ASD is
Explanation of Solution
Calculation:
Write the equation to calculate the factored load.
Here, the dead load is
Substitute
Write the expression to calculate the load applied in
Here, the total load is
Substitute
Write the expression to calculate the load applied in
Here, the and load component in
Substitute
Calculate the horizontal direct shear component.
Substitute
Calculate the vertical direct shear component.
Substitute
Write the expression for the moment for
Here, moment generated is
Substitute
Write the expression for the moment for
Here, moment generated is
Substitute
Write the expression for the moment for
Here, the total moment generated is
Substitute
Check the safety for the bottom right bolt.
Calculate the distance of the bolt from the centroid.
Calculate the load coming on the critical bolt in x direction due to eccentricity.
Substitute
Calculate the load coming on critical bolt in y direction due to eccentricity.
Substitute
Calculate the
Substitute
Calculate the
Substitute
Calculate the total fastener force.
Substitute
Write the equation to calculate the nominal shear capacity of bolt.
Here, the nominal shear capacity is
Substitute
Calculate the diameter of bolt.
Substitute
Therefore, adopt the bolt diameter of
Check for safety:
Calculate the bearing deformation strength of bolt.
Substitute
Calculate the hole diameter.
Calculate the clear distance for edge bolt.
Substitute
Calculate the tear-out strength of inner bolt.
Substitute
Calculate the clear distance for edge bolt.
Substitute
Calculate the tear-out strength of edge bolt.
Substitute
The minimum of Equations (XXII), (XIX) and (XVIII) is the value of
Calculate the allowable strength of bolt by substituting
The strength is greater than the design strength.
Therefore, adopt
Conclusion:
Thus, the size of bolt is
Want to see more full solutions like this?
Chapter 8 Solutions
STEEL DESIGN (LOOSELEAF)
- A trapezoidal combined footing 5.5 m long is to supporttwo 400 mm square columns 5 meters apart. The center ofthe columns are both 0.25m away from property lines. Theleft column carries 675 kN while the right column 825 kN.The allowable soil pressure is 126 kPa. Assume footing is0.5m thick with soil backfill 0.7m thick. Weight of concreteis 23.6 kN/m3 and of soil is 20.4 kN/m3. 1. Determine the required footing area.2. Find the width of the smaller end of the footing.3. Calculate the width of the larger end of the footing.Ans:15.01m2, 2m, 3.5m please show the solution. Answer is providedarrow_forwardH.W: Evaluate the integral 1. 1 1 }} 0 y x²exy dxdy 2. 1 ܐy 2 dxdyarrow_forwardGiven the following end areas for cut & fill, complete the eart calculation using a shrinkage of 10%. Then draw the M.H.D. and the longitudinal pro of the earthworks & find the following: a) Limit of Economic Haul (L.E.H.). b) Freehaul volume (F.H.V.). c) Overhaul volume (O.H.V.). d) Waste volume. e) Borrow volume. f) Total cost of the earthworks. Given that: -Cost of overhaul = 30 ID/m².station. -Cost of borrow-120 ID/m³. - Cost of freehaul - 70 ID/m². -Freehaul Distance (F.H.D.)- 200m-2 stations. Areas (m²) Station Volumes (m) Cut Fill Cut+ Fill- 0 10 Corrected Fill- 1100 1 12 1300 2 14 1500 3 146 1500 14 350 550 250 275 10 5 16 96 1300 1430 6 1500 1650 14 7 1300 1430 12 S . 1000 1100 8 9 300 200 220 12 10 1400 16 11arrow_forward
- Calculate the clean bed head loss for a filter consisting of uniformly graded sphere silica beads (shape factor p = 1), all having a diameter of 1 mm, packed into a 5 m x 5 m filter bed with depth D = 8 m, with a bed porosity of ε = 0.4, treating a flow rate of 0.025 m³/s. Assume a viscosity of 1.25x10-6 m2/s. Report your answer with the units of meters and round to the nearest 0.1.arrow_forwardUsing the book Olin's Construction: Principles, Materials, and Methods By H. Leslie SimmonsUsing Materials for a Small Residential House Compile A detailed list of every single material used in the construction of this small Residential Home. Your list will be broken up into 5 stages FOUNDATION, FRAMING, ROUGH IN, ROOF, FINISH You do not need to estimate the quantity of materials. Choose the exterior and interior finishes. Find 3 SDS sheets for materialsfor each stage of the build . REMEMBER EVERY ITEM MISSED IN AN ESTIMATE WILL COST YOU MONEY. HOUSE DETAILS • Slab foundation • UTILITIES AND GROUND WORK IS COMPLETED . • Single Story • Copper plumbing or PEX 2x6 Wood Framing Gas Water Heater Gas appliances ROOF: asphalt shingles , Stick framing, Cross hipped roof House has Heating and A/C EXAMPLE: FOUNDATION Concrete Wood For formsarrow_forwardA1.4- Determine the factored moment resistance for the flanged beam (simply supported) shown in Figure 4. Given: Beam span L = 8m fc = 25MPa fy=400MPa As = 3-35M *350* mm 1.5 m Figure 4 *350* mm -60mmarrow_forward
- A2.3- a simply supported reinforced concrete beam of rectangular cross-section is shown in Figure 3. The beam supports a uniform dead load of 20 kN/m (excluding the beam self-weight) and a uniform live load of 20 kN/m. The beam width is restricted to 400 mm. The maximum aggregate size is 20 mm. We are using 10M bars for stirrups and 25M bars for tension steel. Concrete is type N with f'c = 35 MPa and fy = 400 MPa. The beam needs to have 2hr fire rating. Design the beam for the given load, considering the reinforcement ratio p < 0.5 pb Figure 3 WDL = 20 kN/m WLL= 20 kN/m 8.0 marrow_forwardOlin's Construction: Principles, Materials, and Methods By H. Leslie Simmonsarrow_forwardThe L6 x 4 x 1/2 single angle shown has two rows of bolts. Each leg has one row (one line) of 5/8 in bolts in each leg as shown. Determine the net area (An). If needed, I attached the section properties from AISC manual for L6x4x1/2.arrow_forward
- 3. Determine the reactions at the supports for the frame shown in following. 36.5 kN/m 14.6 kN/m Hinge R = 10 m 10 m -10 marrow_forward# 4 F3 Existing Flocculation Basin Design Parameters at 22.5 MGD: A) # of Basins: 5 B) # of Stages per Basin: 2 c) Basin Dimensions: (30 ft. X 4 ft. X 15 ft.) D) Volume per Basin 10,800 cf (80,787 Gal) E) Total Flocculation Volume: 54,000 cf (406,920 Gal) F) Theoretical Unit Detention Time: 25.9 minutes G) Flow through Velocity (Q): 1.16 ft/min Deliverables: 1) Determine if the existing flocculation basins are sufficient to accommodate the projected future capacity. A) Current Capacity: 22.5 MGD B) Future Capacity: 34.5 MGD for 110,000 residents C) If not, determine the number of additional flocculation basins needed to accommodate the future capacity of 34.5 MGD. a) Ignore this bullet point 2) Specify the basic dimensions (length, width, water height, weir dimensions, etc.) of these additional flocculation basins. 3) Specify the design flow rate, detention time, and the flow-through velocity for each basin under the maximum future capacity of 34.5 MGD, assuming one of the basins is…arrow_forwardA1.4- Determine the factored moment resistance for the flanged beam (simply supported) shown in Figure 4. Given: Beam span L = 8m fc = 25MPa fy=400MPa As = 3-35M *350* mm 1.5 m Figure 4 *350* mm -60mmarrow_forward
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
