(a)
If all the spacing and edge distance requirements are adequate.

Answer to Problem 7.3.1P
The spacing and the edge distance provided are adequate.
Explanation of Solution
Given:
Tension member is
Thickness of the gusset plate is
Diameter of the bolts is
Steel Used is
Calculation:
The properties for
The ultimate tensile stress is
Write the expression for minimum spacing.
Here, diameter of the bolt is
Substitute
The minimum spacing between the bolts is
For the edge distance to be adequate, the value of edge distance should be greater than or equal to the value of minimum edge distance.
Here, edge distance is
The value of edge distance is
Conclusion:
Thus, the spacing and the edge distance provided are adequate.
(b)
The nominal bearing strength of each bolt.

Answer to Problem 7.3.1P
The nominal bearing strength of the edge bolt is
Explanation of Solution
Calculation:
Write the expression for nominal bearing strength of a bolt.
Here, the nominal bearing strength is
With the upper limit of nominal bearing strength of the bolt,
Write the expression to calculate the value of
Here, height of the bolt is
Write the expression to calculate the value of
Here, spacing between the bolts is
Write the expression to calculate the height of the bolt.
Calculate the value of
Substitute
Calculate the value of
Substitute
Calculate the nominal bearing strength for edge bolts.
Substitute
Calculate the upper limit of nominal bearing strength for edge bolts.
Substitute
Thus, the minimum value of
Calculate the value of
Substitute
Calculate the nominal bearing strength for inner bolts.
Substitute
Calculate the upper limit of nominal bearing strength for inner bolts.
Substitute
Thus, the minimum value of
Conclusion:
Thus, the nominal bearing strength of the edge bolt is
Want to see more full solutions like this?
Chapter 7 Solutions
STEEL DESIGN (LOOSELEAF)
- The capacity of a freeway lane with free-flow speed of 70mph and jam density average vehicle spacing 40ft assuming greenshields’s model applies. Please explain step by step and show formulaarrow_forward3. For problems given below, determine all the reaction forces and plot force diagrams for normal forces (N), shear force (T), and moments (M). 150 lb/ft 10 ft C B 2 ft 2 ft -4 ft D 250 lb/ft 50 lb/ft B 150 lb-ft 150 lb-ft -20 ft 10 ft -20 ft 200 lb-ftarrow_forwardPlease explain step by step and show all the formula usedarrow_forward
- By using the yield line theory, determine the moment (m) for an isotropic reinforced concrete two- way slab shown in figure under a uniformly distributed load. Using moment method 5 2 7.0m 1 A I c.g. * B c.g 5 2 B c. g. ㄨˋ A A 2.5 2.0 2.5 5.0marrow_forwardPlease explain step by step and include any formula usedarrow_forwardPlease explain step by step and include any formular usedarrow_forward
- 2 1d/T₁₂ = 1/2 n First impulse E ("œw / ])÷(1) '7 J-1 -1- -2+ 0 0.5 1 1.5 2arrow_forwardBars AD and CE (E=105 GPa, a = 20.9×10-6 °C) support a rigid bar ABC carrying a linearly increasing distributed load as shown. The temperature of Bar CE was then raised by 40°C while the temperature of Bar AD remained unchanged. If Bar AD has a cross-sectional area of 200 mm² while CE has 150 mm², determine the following: the normal force in bar AD, the normal force in bar CE, and the vertical displacement at Point A. D 0.4 m -0.8 m A -0.4 m- B -0.8 m- E 0.8 m C 18 kN/marrow_forwardDraw the updated network. Calculate the new project completion date. Check if there are changes to the completion date and/or to the critical path. Mention the causes for such changes, if any. New network based on the new information received after 15 days (Correct calculations, professionally done). Mention if critical path changes or extended. Write causes for change in critical path or extension in the critical path.arrow_forward
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage LearningArchitectural Drafting and Design (MindTap Course...Civil EngineeringISBN:9781285165738Author:Alan Jefferis, David A. Madsen, David P. MadsenPublisher:Cengage Learning