EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
thumb_up100%
Chapter 6, Problem 37R
Two 125-volt receptacles on a 20-ampere, 120-volt branch circuit are installed in the laundry room. One (1) is for the washer and is within 6 ft of the laundry sink and the other (2) is on a wall more than 6 ft from the sink. The receptacles are required to have: (Circle the correct answer.)
- a. GFCI and AFCI protection for both (1) and (2)
- b. GFCI and AFCI protection for (1) and only GFCI protection for (2)
- c. GFCI and AFCI protection for (2) and only AFCI protection for (1)
- d. GFCI and AFCI protection for (1) and only AFCI protection for (2)
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
The easiest place to install an ammeter into a stepper motor driver/motor circuit for system diagnostics is to
attach the meter in series with the driver’s power supply lead.
remove a fuse and place the meter leads across the fuse clips.
disconnect a motor lead and attach the meter in series with that lead.
connect the meter across the center tap and phase leads of the motor.
20. Four electricians are discussing wiring under raised floors in information technology equipment rooms.Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings betweenother occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up thewalls and floors between other occupancies. Electrician C says that the room must employ a disconnectingmeans that removes half of the power to all equipment in the room. Electrician D says that a disconnectingmeans isn't necessary for the room. Which of the following statements is correct?A. Electrician A is correct.B. Electrician D is correct.C. Electrician B is correct.D. Electrician C is correct.
Four electricians are discussing wiring under raised floors in information technology equipment rooms. Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings between other occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up the walls and floors between other occupancies. Electrician C says that the room must employ a disconnecting means that removes half of the power to all equipment in the room. Electrician D says that a disconnecting means isn't necessary for the room. Which of the following statements is correct?
A. Electrician B is correct.
B. Electrician D is correct.
C. Electrician A is correct.
D. Electrician C is correct.
Chapter 6 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 6 - Explain the operation of a ground-fault circuit...Ch. 6 - Prob. 2RCh. 6 - Where must GFCI receptacles be installed in...Ch. 6 - Prob. 4RCh. 6 - Prob. 5RCh. 6 - A homeowner calls in an electrical contractor to...Ch. 6 - Prob. 7RCh. 6 - Extremely long circuit runs connected to a GFCI...Ch. 6 - If a person comes in contact with the hot and...Ch. 6 - What might happen if the line and load connections...
Ch. 6 - Is a GFCI receptacle permitted be installed as a...Ch. 6 - Prob. 12RCh. 6 - Prob. 13RCh. 6 - Prob. 14RCh. 6 - Prob. 15RCh. 6 - Construction sites can be dangerous because of the...Ch. 6 - Prob. 17RCh. 6 - Prob. 18RCh. 6 - The term SPD is becoming quite common. What do the...Ch. 6 - Transients (surges) on a line can cause spikes or...Ch. 6 - Prob. 21RCh. 6 - Prob. 22RCh. 6 - Some line transients are not damaging to...Ch. 6 - Briefly explain the operation of an immersion...Ch. 6 - What range of leakage current must trip an IDCI?Ch. 6 - Prob. 26RCh. 6 - Other than for a few exceptions, the NEC requires...Ch. 6 - In an old house, an existing nongrounding...Ch. 6 - Prob. 29RCh. 6 - NEC 210.12(A) requires AFCI protection for the...Ch. 6 - When installing GFCI and AFCI circuit breakers in...Ch. 6 - Prob. 32RCh. 6 - Prob. 33RCh. 6 - A switch that is located inside a bedroom for an...Ch. 6 - Which of the following installations for a kitchen...Ch. 6 - The receptacle outlets in the garage are required...Ch. 6 - Two 125-volt receptacles on a 20-ampere, 120-volt...Ch. 6 - Prob. 38R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardWho has the responsibility for Code interpretations? When are rules in the PEC mandatory and when are they advisory? What color-coding is required on multiwire branch circuits? What is the basis for figuring the general lighting loads in occupancies?arrow_forwardIf a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forward
- 5. When seeking to measure the voltage of a wall outlet (120 Volts AC) an electie: needs to do the following to prepare the Simpson 260 meter for measurement an the words to make the following statements correct). a. Set the function switch to b. The black lead should be inserted in the jack. c. The red lead should be inserted in the jack. d. The range switch should be set to the position. Note the safety warning at the heading of Section 4.10. The Simpson folks are serious about this and so should we all be. 150 assign_ELTE108_Handout_Lab_02_2020-02-05 Page 4 of 12arrow_forwardTwo of the circuits will be a 3-wire, multi-wire branch circuit (Edison 3-wire). The location of the devices is to be determined by the student. The student shall be responsible for selecting the correct circuits, do not ask the instructor which circuit number should be used. Circuit A. One lampholder and one duplex receptacle controlled by a Single Pole Switch. Circuit B. Single Pole Switch controlling the top half of a duplex receptacle that when energized, is indicated by a Pilot-light at the Single Pole Switch location; plus an Isolated Ground Duplex Receptacle that is always hot. Circuit C. The bottom half of the switched receptacle on Circuit ‘B’ is to be always hot; plus another Duplex Receptacle that is controlled from two locations using a Coast 3-Way wiring-system.arrow_forward21.Which of the following wiring methods may be used inside the duct used for vapor removal and ventilation of commercial type cooking equipment? (a.) nonmetallic sheathed cable (b.) EMT (c.) rigid steel conduit (d.) none of these 22. Ground-fault circuit-interrupter (GFCI) protection is required in all of the following locations EXCEPT: (a.) kitchen receptacles in an office building lunchroom installed within 6’ of the sink (b.) kitchen receptacles in a dwelling installed to serve counter top surfaces 10’ away from the sink (c.) receptacles in an office building restroom which has only a basin and toilet (d.) receptacle provided for servicing a rooftop air conditioning unit on the roof of a warehouse 23. Where GFCI protection is located in the power supply cord for an outdoor portable sign, the ground-fault circuit interrupter shall be located within _____inches of the attachment plug. (a.) 6 (c.) 18 (b.) 12 (d.) 24arrow_forward
- An isolator is used to: Select one: a. To be mounted on towers for insulation purpose b. All of the above c. to disconnect part of the system for maintenance from live circuit d. Insulate the wires to avoid electrocution and short circuits Clear my choicearrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forward
- Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardBuild a ladder and wiring diagram Circuit A. One lampholder and one duplex receptacle controlled by a Single Pole Switch. Circuit B. Single Pole Switch controlling the top half of a duplex receptacle that when energized, is indicated by a Pilot-light at the Single Pole Switch location; plus an Isolated Ground Duplex Receptacle that is always hot. Circuit C. The bottom half of the switched receptacle on Circuit ‘B’ is to be always hot; plus another Duplex Receptacle that is controlled from two locations using a Coast 3-Way wiring-system.arrow_forward1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License