Textbook Question
thumb_up100%
Chapter 6, Problem 28R
In an old house, an existing nongrounding non-GFCI-type receptacle in a bathroom needs to be replaced. According to 406.4(D)(3), this replacement receptacle shall be: (Circle the correct answer.):
- a. a nongrounding-type receptacle.
- b. a GFCI-type receptacle or be GFCI protected in some other way, such as changing the breaker that supplies the receptacle to a GFCI type.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Four electricians are discussing wiring under raised floors in information technology equipment rooms. Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings between other occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up the walls and floors between other occupancies. Electrician C says that the room must employ a disconnecting means that removes half of the power to all equipment in the room. Electrician D says that a disconnecting means isn't necessary for the room. Which of the following statements is correct?
A. Electrician B is correct.
B. Electrician D is correct.
C. Electrician A is correct.
D. Electrician C is correct.
Building Service Subject
11 and 12 , i need this answer
Chapter 6 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 6 - Explain the operation of a ground-fault circuit...Ch. 6 - Prob. 2RCh. 6 - Where must GFCI receptacles be installed in...Ch. 6 - Prob. 4RCh. 6 - Prob. 5RCh. 6 - A homeowner calls in an electrical contractor to...Ch. 6 - Prob. 7RCh. 6 - Extremely long circuit runs connected to a GFCI...Ch. 6 - If a person comes in contact with the hot and...Ch. 6 - What might happen if the line and load connections...
Ch. 6 - Is a GFCI receptacle permitted be installed as a...Ch. 6 - Prob. 12RCh. 6 - Prob. 13RCh. 6 - Prob. 14RCh. 6 - Prob. 15RCh. 6 - Construction sites can be dangerous because of the...Ch. 6 - Prob. 17RCh. 6 - Prob. 18RCh. 6 - The term SPD is becoming quite common. What do the...Ch. 6 - Transients (surges) on a line can cause spikes or...Ch. 6 - Prob. 21RCh. 6 - Prob. 22RCh. 6 - Some line transients are not damaging to...Ch. 6 - Briefly explain the operation of an immersion...Ch. 6 - What range of leakage current must trip an IDCI?Ch. 6 - Prob. 26RCh. 6 - Other than for a few exceptions, the NEC requires...Ch. 6 - In an old house, an existing nongrounding...Ch. 6 - Prob. 29RCh. 6 - NEC 210.12(A) requires AFCI protection for the...Ch. 6 - When installing GFCI and AFCI circuit breakers in...Ch. 6 - Prob. 32RCh. 6 - Prob. 33RCh. 6 - A switch that is located inside a bedroom for an...Ch. 6 - Which of the following installations for a kitchen...Ch. 6 - The receptacle outlets in the garage are required...Ch. 6 - Two 125-volt receptacles on a 20-ampere, 120-volt...Ch. 6 - Prob. 38R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- [Fill-in-the-blank] in dwelling units shall supply only loads within that dwelling unit or no loads associated only with that dwelling unit. Select one: a. None of these b. Ground-fault protection c. Service-entrance conductors d. Branch circuitsarrow_forwardTrue or False: Receptacles used on the job site should be protected with a GFCI.arrow_forwardf a grounding means does not exist in outlet, nongrounding-type receptacle can be replaced with GFCI device, but it must be marked " ." A.Nongrounding GFCI B. Externally Grounded C. No Grounding Protection D. GFCI Protectedarrow_forward
- schedules are typically provided to detail the circuits and overcurrent protection required for listribution equipment. Branch-circuit - Outlet C. d. ore distribution points for electrical in .... Switch Panelboardarrow_forward11. Which of the following statements about the use of structural steel as an equipment grounding conductor (EGC) in an AC system is correct? A. Structural steel can be used as an EGC when it's bonded at both ends.B. Structural steel isn't allowed for use as an EGC.C. Structural steel must have an EGC bonding jumper every three feet of structure. D. Structural steel can be used as an EGC bonding jumper between panelboards. 12. Which of the following statements about equipment grounding conductors is true? A. They increase voltages above ground potential on conductors and equipment enclosures during normal operation. B. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor. C. They must be capable of withstanding the higher level of ground-fault current to perform their safety function. D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-fault conditions. 13. Imagine that…arrow_forward7. If a grounded surface metal box makes direct contact with the mounting strap for a switch or receptacle,then theA. bonding jumper can be undersized.B. neutral conductor will operate as the equipment grounding conductor.C. bonding jumper isn't required.D. device must be protected with a GFCI device.arrow_forward
- 20. Four electricians are discussing wiring under raised floors in information technology equipment rooms.Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings betweenother occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up thewalls and floors between other occupancies. Electrician C says that the room must employ a disconnectingmeans that removes half of the power to all equipment in the room. Electrician D says that a disconnectingmeans isn't necessary for the room. Which of the following statements is correct?A. Electrician A is correct.B. Electrician D is correct.C. Electrician B is correct.D. Electrician C is correct.arrow_forwardAll of the following can provide GFCI protection for kitchen countertop convenience receptacles EXCEPT:__________. Select one: a. AFCI/GFCI circuit-breakers b. by installing a single feed-through type GFCI receptacle to protect downstream receptacles c. AFCI circuit-breakers d. GFCI circuit-breakersarrow_forward5. Which of the following descriptions of a ground ring is correct?A. A ground ring is a circular formation that's made up of six or more grounding electrodes.B. A ground ring is a coiled conductor that's buried underneath a utility pole.C. A ground ring is a device that's used to clamp a conductor to a water pipe.D. A ground ring is a bare copper conductor that will encircle an entire structure underground.arrow_forward
- of p o How many conductors enter the ceiling fan/light wall box? Switch ond out let boxes s tirst 10. What type and size of box may be used for the ceiling fan/light wall box?. 11. What type of covers are used with 4 in. square outlet boxes? 12. a. Does the circuit for the Master Bedroom have a grounded circuit conductor? b. Does it have an equipment grounding conductor? c. Explain the difference between a "grounded" conductor and an "equipment grounding" conductor. 13. Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to ft complete the circuit supplying the Master Bedroom? Two-wire cable: ft (- m). m). Three-wire cable: 14. If the cable is laid in notches in the corner studs, what protection for the cable must be provided? 15. How high are the receptacles mounted above the finished floor in this bedroom? 16. Approximately how far from the bedroom door is the first receptacle mounted? (See the plans.) 17. What is the distance from the finished floor to…arrow_forward13. How can a duplex receptacle be converted to a split-wired receptacle? O A. By running separate wires O B. By using the bypass terminals OC. By strapping it O D. By removing the contact link highlighted on the review page).arrow_forward6. According to the NEC, allowance for the future expansion of installations isA. an exception.B. in everyone's best interest.C. defined.D. a requirement.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License