Textbook Question
100%
Book Icon
Chapter 6, Problem 1R

Explain the operation of a ground-fault circuit interrupter. Why are GFCI devices used? Where are GFCI receptacles required? _________________________________

Expert Solution & Answer
Check Mark
To determine

Explain the operation and need of a ground-fault circuit interrupter (GFCI) and also mention the area that requires GFCI.

Explanation of Solution

Discussion:

A device that senses an unbalance current flow is ground-fault circuit interrupter (GFCI). When a ground fault exists in a circuit, an unbalanced current occurs. This type of current flow may cause death or injury to a human being. The flow of unbalance current is stopped by GFCI. When the value of current exceeds 6mA, the GFCI trips the circuit to OFF. The GFCI protection is supplied by a branch circuit breaker, GFCI receptacle or by a dual function AFCI/GFCI.

According to an article NEC 210.8, a 125 volt single-phase 15 and 20 amperes branch circuits require a GFCI protection at specific location such as kitchens, bathrooms, outdoors, garages, and within 6ft(1.8m) of the top inside edge of the bowl of sink, swimming pools, and hot tubs.

Conclusion:

Thus, the operation, need and the area that require GFCI are explained.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Inth big below:- A 500m B Zoom с 180011 I=50A I-60A I-804 06 ·0.7 0.8 lag. unit) Teading Pf P.F Pl A I sing phase distributor of 3/cm = The distance from point A To B is 500m distance from point A To C is /200m The distance from point A To D is 3000m The impedance of each part is. ZAB-0.51j0.8 -2/km ZBC= 0.7+71.2 12/1cm ZCD = 1.3772.5 -2/1cm The voltage of end for is VD= 220 Volt Find : 1- sending Voltage senting power 2- 5
Consider the circuit diagram below, where the load is indicated by the dashed box. Compute the apparent power and power factor of the load. Use power factor correction to correct the power factor of the load to 0.8 lagging. Your solution should include a circuit diagram of your modified circuit.
Consider the circuit diagram below. What is the power factor of the circuit? Is it leading or lagging? Draw the power factor triangle of the circuit without calculating the individual power consumption of each component.

Chapter 6 Solutions

EBK ELECTRICAL WIRING RESIDENTIAL

Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
FMPR-103 pt1 l Power Systems Protection v1; Author: L&D for Protection and Control;https://www.youtube.com/watch?v=ELWncjsh5uE;License: Standard Youtube License