All of these are good reasons for replacing an accumulator unit, except
- The accumulator/dryer is punctured.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
In Pensky Martin's apparatus what is the purpose of air jacket surrounding the oil cup.
33. An open drive condensing unit has the
following factory delivered options.
Compressor maximum speed 550 rpm
Compressor pulley size 600mm • Factory
supplied motor pulley size 200mm • Motor
speed rating 1400 rpm Pre-commissioning
tests suggest that the suction pressure is too
high, the system capacity is below
requirement, and the compressor speed
needs to be increased. Assuming that the
motor has an adequate power rating to drive
the compressor to its maximum speed, what
size motor pulley would be required to
increase the compressor speed by an
additional 10%? Áll calculations can be
rounded to the nearest unit of 10. All
calculations are to be shown.
Wet gas coming from a reservoir flowing into the wellbore turns from liquid to gas in separation equipment is called as
a. Evaporation
b. Condensation
c. Sublimation
d. Vaporization
e. Distilling
Chapter 55 Solutions
Automotive Technology
Ch. 55 - What should you do if you suspect that an...Ch. 55 - Explain how dye can be used to find leaks in the...Ch. 55 - What is the purpose of the thermostatic switch in...Ch. 55 - Why should the probe of an electronic leak...Ch. 55 - How will air trapped in the A7C system affect...Ch. 55 - Which of the following statements best defines the...Ch. 55 - Which of the following statements is not true...Ch. 55 - To charge an air-conditioning system while it is...Ch. 55 - All of the following are true statements about...Ch. 55 - A very important part of a performance test on an...
Ch. 55 - While conducting a pressure test on an A/C system,...Ch. 55 - The high-side pressure on a system with a cycling...Ch. 55 - When checking an A/C system, the evaporators inlet...Ch. 55 - All of these are good reasons for replacing an...Ch. 55 - In an AZC system, if the low-side pressure is...Ch. 55 - Technician A says that evacuating (pumping down)...Ch. 55 - Technician A says that some refrigerant leaks can...Ch. 55 - Technician A says that the presence of oil around...Ch. 55 - Technician A says that a faulty accumulator will...Ch. 55 - Technician A says that air in the system can cause...Ch. 55 - Technician A feels up and down the face or along...Ch. 55 - Technician A says that a manifold gauge set can be...Ch. 55 - While discussing an inoperative blend air door:...Ch. 55 - Two technicians were discussing how comparing the...Ch. 55 - While conducting an A/C system performance test:...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When condenser tubes become fouled, they may be cleaned by A. using a steel brush. B. using a brass brush. C. using a chisel and hammer. D. running a mixture of sand and water through them.arrow_forwardWhy do some condensers have to be cleaned with brushes and others with chemicals?arrow_forwardWhat will happen if the float in an oil separator collapses?arrow_forward
- What is the advantage of using an injector-type mixing chamber?arrow_forwardWhich of the following statements is not true about orifice tube systems? The suction line must be cool to the touch from the evaporator outlet to the compressor. The liquid line from the condenser outlet to the evaporator inlet should be cool. The evaporator should feel very cold. The accumulator must be cool to the touch.arrow_forwardTechnician A feels up and down the face or along the return bends of the condenser for a temperature change and says that there should be a gradual change from hot to warm from the bottom to the top. Technician B says that a restriction in the condenser will be evident by a sudden change in temperature. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forward
- Surface condensers allow the two fluids to mix, is the statement true or falsearrow_forwardWhere do you see condensation in the setup?arrow_forwardTechnician A says that some refrigerant leaks can also be traced to pinholes in the evaporator caused by acid, which forms when water and refrigerant mix. Technician B says that leaks are most often found at the compressor hose connections and at the various fittings and joints in the system. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forward
- How does an injector-type mixing chamber work?arrow_forwardA lawnmower stops running after a short period of time. The fuel tank filler cap is removed and an almost fuel tank of fuel is found, so the cap is reinstalled and the engine restarted. The engine runs again for a short time and then dies so the cap is removed again and the process repeats. Tech a says the problem may be due to a clogged vent in the fuel cap. The b says that the intake mainfold gasket may be defective. Who is correct?arrow_forwardHow does a thermal expansion valve work?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningWelding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage Learning
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY