Automotive Technology
7th Edition
ISBN: 9781337794213
Author: ERJAVEC, Jack.
Publisher: Cengage,
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 55, Problem 8MC
When checking an A/C system, the evaporator’s inlet and outlet tubes feel like they are at the same temperature. Which of these could cause this?
- A plugged evaporator
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Surface condensers allow the two fluids to mix, is the statement true or false
The centrifugal compressor is used for refrigerants that require short
displacement and high condensing pressure.
True
False
What is fan static pressure?
Chapter 55 Solutions
Automotive Technology
Ch. 55 - What should you do if you suspect that an...Ch. 55 - Explain how dye can be used to find leaks in the...Ch. 55 - What is the purpose of the thermostatic switch in...Ch. 55 - Why should the probe of an electronic leak...Ch. 55 - How will air trapped in the A7C system affect...Ch. 55 - Which of the following statements best defines the...Ch. 55 - Which of the following statements is not true...Ch. 55 - To charge an air-conditioning system while it is...Ch. 55 - All of the following are true statements about...Ch. 55 - A very important part of a performance test on an...
Ch. 55 - While conducting a pressure test on an A/C system,...Ch. 55 - The high-side pressure on a system with a cycling...Ch. 55 - When checking an A/C system, the evaporators inlet...Ch. 55 - All of these are good reasons for replacing an...Ch. 55 - In an AZC system, if the low-side pressure is...Ch. 55 - Technician A says that evacuating (pumping down)...Ch. 55 - Technician A says that some refrigerant leaks can...Ch. 55 - Technician A says that the presence of oil around...Ch. 55 - Technician A says that a faulty accumulator will...Ch. 55 - Technician A says that air in the system can cause...Ch. 55 - Technician A feels up and down the face or along...Ch. 55 - Technician A says that a manifold gauge set can be...Ch. 55 - While discussing an inoperative blend air door:...Ch. 55 - Two technicians were discussing how comparing the...Ch. 55 - While conducting an A/C system performance test:...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Technician A says that air in the system can cause excessive pressure within the system, restricting the refrigerants ability to change its state from gas to liquid within the refrigeration cycle. Technician B says that moisture can cause freeze-up at the cap tube or expansion valve, which restricts refrigerant flow or blocks it completely. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardTechnician A says that some refrigerant leaks can also be traced to pinholes in the evaporator caused by acid, which forms when water and refrigerant mix. Technician B says that leaks are most often found at the compressor hose connections and at the various fittings and joints in the system. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardTechnician A says that when the refrigerant is pumped out of the compressor and sent to the condenser, heat in the refrigerant is moved to the outside air by conduction and convection. Technician B says that the refrigerant leaves the bottom of the condenser as a high-pressure, high-temperature liquid. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forward
- Which of the following statements is not true about orifice tube systems? The suction line must be cool to the touch from the evaporator outlet to the compressor. The liquid line from the condenser outlet to the evaporator inlet should be cool. The evaporator should feel very cold. The accumulator must be cool to the touch.arrow_forwardTechnician A says that when the A7C system is off, the refrigerant occupies the system as a liquid and its pressure is the same throughout the system. Technician B says that refrigerant is pumped out of the compressor as a high-pressure, high-temperature vapor and is sent to the condenser. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardWhat are two methods used to evaporate condensate from the evaporator?arrow_forward
- Briefly describe an oil-less refrigerant recovery unit.arrow_forwardWhat special valve is used in a refrigerated air drier? A. Four-way valve B. Defrost valve C. Three-way valve D. Hot gas bypass valvearrow_forwardWhen condenser tubes become fouled, they may be cleaned by A. using a steel brush. B. using a brass brush. C. using a chisel and hammer. D. running a mixture of sand and water through them.arrow_forward
- In an AZC system, if the low-side pressure is lower than normal, which of the following is the least likely cause? A faulty metering device Poor airflow across the evaporator A restriction in the low side of the system The system being overcharged with refrigerantarrow_forwardEvaporative condenser is used only air as condensing medium to condense the hot vapour refrigerant. True O Falsearrow_forwardChoose the correct answer The discharge pressure of a refrigerant should be as constant as possible The discharge pressure of a refrigerant should be as low as possible The discharge pressure of a refrigerant should be as high as possiblearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningWelding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY