![Electric Motor Control](https://www.bartleby.com/isbn_cover_images/9781305177611/9781305177611_largeCoverImage.jpg)
Electric Motor Control
10th Edition
ISBN: 9781305177611
Author: Herman
Publisher: Cengage
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 44, Problem 3SQ
If an armature has a resistance of 0.5 ohm, what series resistance must be used to limit the current to 30 amperes across a 230-volt circuit at the instant of starting? What is the power rating?
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Want to see the full answer?
Check out a sample textbook solution![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
There are three 15,000-ohm resistors connected in series across a 120-volt DC source.
What is the voltage distribution across each resistor?
What would be the voltage reading across the first resistor if a 0-120 volt meter with a 100-ohm per volt sensitivity is used?
What would be the voltage reading across the first resistor if a 0-120 volt meter with a 10,000 ohm per volt sensitivity is used?
How does the Zenerimpedance affect the voltage across the terminals of the device?
What are the range of voltages can the Logo SIEMENS work within? Which model DC and which one AC supply?
Chapter 44 Solutions
Electric Motor Control
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- We want to measure the amount of current flowing to an old light bulb. We expect that the result will be around 5A. How should we connect the probes of the multimeter? Drag the connector images to the correct locations and "Not Connected" images to the rest. SUDE SWITCH: LEFT- OFF MIDDLE- DCVOLTS DC mA NUMERICAL VALUE OF VOLTS OR mA OR OHMS DISPLAYED HERE 0.00 OHMS RIGHT - AC VOLTS AC mA OFFOD AC DC-A DM 8010 MOVE ROTARY SWITCH TO THIS AREA TO READ OHMS 1000 200 20 MOVE ROTARY SWITCH TO THIS AREA TO READ VOLTS (SELECT RANGE) 200 (SELECT RANGE) 2K. 20K. •200 20u MOVE ROTARY SWITCH TO THIS AREA TOo READ mA (SELECT RANGE) 200K 20u *200u m 2M 20M 200m 20m 10A COM vn PROBES Windows'u Etkinleştir Windows'u etkinleştirmek için Ayarlar'a gidin. NOT CONNECTEDarrow_forwardHow does the load power vary with the load resistance?arrow_forwardA voltage source an IR drop of 40 volts across a 20 ohms R1, 60 volts across a 30 ohms R2, and 180 volts across a 90 ohm R3, all in series. How much is the applied voltage?arrow_forward
- QUESTION 5 We would like to run the power wires for both cooling pumps in the same RMC from the Breaker panel to a junction box above the control panel. What size ungrounded conductors do we need for the 100 amp load? All conductors have typeTHHN insulation. A #6 AWG B #3 AWG C #4 AWG D #1 AWGarrow_forwardThree types of electric devices A, B, and C are connected in series across a 115-volt ac source, and the voltage drops across the individual units are equal. If EB leads EA by 90 elec deg and EC lags behind EA by 90 elec deg, what are the emfs across A, B, and C?arrow_forwardWhat is factor of a cable at 5 degrees celcius when calculating resistancearrow_forward
- What is the common type in electricity in underground cablesarrow_forwardWhat will happen if the DC voltage in the clamping circuit is replaced by an AC source?arrow_forwardNo matter how much you try to adjust the voltage knob, voltage cannot be set when attempting to reach a DC power supply of 12VDC. What are the possible solutions to this problem?arrow_forward
- 9) Does this switch (in the open state) have a Low resistance or a high resistance between its terminals?arrow_forward4 thyristors rated 200 V in series. The operating voltage of the string is 600 V. Derating factor of the string is?arrow_forwardUsing a DMM you are troubleshooting a 480 volt, 3 phase power feeding a fused disconnect connected to a 3 phase, 1 H.P. motor. Your findings are as follows Phase A = 56 amps, Phase B = 55 amps and Phase C = 52 ampsFind the current unbalance in percent and determine if this is acceptable.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781133702818/9781133702818_smallCoverImage.gif)
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337399128/9781337399128_smallCoverImage.gif)
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Why HIGH VOLTAGE DC power Transmission; Author: ElectroBOOM;https://www.youtube.com/watch?v=DFQG9kuXSxg;License: Standard Youtube License