EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 3, Problem 34R
To determine
Explain how the wall receptacle outlets are related to the receptacle’s position near the sliding glass door.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
Answer the following:
A) Type of clipper circuit per level of clipping.
1. ___________
2. ___________
3. ___________
B) Type of clipper circuit per non-linear devices used.
1. ___________
2. ___________
C) Other term for clipper circuit.
1. ___________
2. ___________
3. ___________
QUESTION 5
A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle?
a
It must be secured by at least two screws.
b
The single 6/32 screw holding it in the cover must be tight.
c
It must be secured directly to the 4 inch square box.
d
It is not permitted to be installed in raised covers.
Chapter 3 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardAn open in one of the heated rear window grid elements can be repaired by ______. a. pealing the heat grid off the glass with a heat gun and installing a new grid element b. applying a thin strip of a repair compound to the damaged area c. bridging the damaged area with rosin core solder d. replacing the window glassarrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forward
- When used as service equipment, a panelboard (load center) must be ______________________ that is suitable for use as service equipment, 230.66. If the panelboard (load center) contains the main service disconnect, it must be clearly marked ____________________________________, 230.70(B).arrow_forwardDetermine the proper size of copper wire conductor necessary to apply a 750 W electric motor that is located 100 feet from the panel board. The voltage at the panelboard is 120 volts. The permissible line drop is 1.2 volts. (for your final answer: no decimal places and unit to have one common answer)arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forward
- The plans indicate that you should install a 300 amp branch circuit in schedule 40 PVC with a 4AWG equipment grounding conductor. However, you did not have any 4AWG so you pulled 10AWG instead. With a load connected, the normal circuit current will be ___arrow_forwardMost appliances of the type commonly used in bathrooms such as hair dryers, electric shavers and curling irons have two wire cords. These appliances are ____ insulated or ________ ___________arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forward
- Assignment on Threaded jointsDue date:__________________ ___________________ ________________ Surname Given names IDA power line tower is erected to support a high-voltage power line (see figure below),which includes six phase conductors and three Earth shield wires. The tower isfabricated as a steel structure resting on four square supporting feet bolted to aconcrete foundation with four Anker bolts at each support (see figure below). Theresultant tension force FT from cables on each side of the tower is applied at point m,and can be at 60o to the horizontal plane (sagging downwards) if the tower is installedon a plane or at 30o to the horizontal plane pointed upwards if the tower is installed on ahilly landscape. The gusty wind load, which could be represented with a resultant forceof Fw is applied at the geometric centre of the tower n in any direction in the horizontalplane (see figure below) and tends to shift the tower sideways and topple it. In the caseof an accident when all…arrow_forwardExplain each option & Choose the correct option. 4) The _ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total 5) What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight 6) You're evaluating the components of a multioccupancy building that won't have an on-site employee. To be compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water pump disconnect ..arrow_forwardA branch circuit consists of five (5) convenience outlets. Determine the size of the conductor to be usedto the said branch circuit. Please indicate the type of conductors to be usedarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT