Textbook Question
Chapter 3, Problem 33R
A split-level home has one stairway that has six risers between two levels of the home. Which of the following choices Meets Code? (Circle the correct answer.)
- a. Two three-way switches must be installed (one switch at the top of the stairs, one switch at the bottom of the stairs) to control the lighting for the stairway.
- b. One single-pole switch is permitted on either level to control the lighting for the stairway.
- c. No switches are necessary for the stairway lighting because the lighting on the upper level and the lower level provides enough illumination on the stairway.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Generators can be connected to the electrical system of the residence in several ways
(Select all answers that apply)
Group of answer choices
A. permanent generator where the neutral is not switched by the transfer switch
B. portable generator that has the neutral bonded to the frame and is connected to the dwelling electrical system transfer equipment by a flexible cord
C. permanent generator where the neutral is switched by the transfer switch
D. portable generator that has the neutral isolated or floated from the frame and is connected to the dwelling electrical system transfer equipment by a flexible cord
20. Four electricians are discussing wiring under raised floors in information technology equipment rooms.Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings betweenother occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up thewalls and floors between other occupancies. Electrician C says that the room must employ a disconnectingmeans that removes half of the power to all equipment in the room. Electrician D says that a disconnectingmeans isn't necessary for the room. Which of the following statements is correct?A. Electrician A is correct.B. Electrician D is correct.C. Electrician B is correct.D. Electrician C is correct.
Question 3:
Suppose an engineer designed a fire alarm system for a large warehouse, with multiple
pushbutton switches connected to a single alarm siren:
Siren
Actuating any of the normally-open switches results in the alarm sounding. So far, so good.
Now, suppose that one of the wires connecting one side of several switches to the rest of
the circuit breaks open. What will the result of this failure be?
Siren
break!
Chapter 3 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The NEC requires that a ____________ means be provided for standby power systems. In the case of portable gen sets, this might be as simple as pulling out the plug on the extension cord that is plugged into the receptacle on the gen set. For permanently installed standby power generators, this might be on the gen set and/or separately provided inside or outside of the home.arrow_forwardThe following problems pertain to luminaires in clothes closets. a. Does the Code permit bare incandescent lamps to be installed in porcelain key-less or porcelain pull-chain lampholders? ________________ b. Does the Code permit bare fluorescent lamp luminaires to be installed? ________________ c. Does the Code permit pendant lampholders to be installed? ________________ d. What is the minimum clearance from the storage area to surface-mounted incandescent luminaires? ________________ e. What is the minimum clearance from the storage area to surface-mounted fluorescent luminaires? ________________ f. What is the minimum distance between recessed incandescent or recessed fluorescent luminaires and the storage area? ________________ g. Define the storage area. ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ h. If a clothes hanging rod is installed where there is access from both sides, such as might be found in a large walk-in clothes closet, define the storage area under that rod. ___________________________________ ___________________________________arrow_forwardWho has the responsibility for Code interpretations? When are rules in the PEC mandatory and when are they advisory? What color-coding is required on multiwire branch circuits? What is the basis for figuring the general lighting loads in occupancies?arrow_forward
- 45. A switch or circuit breaker can be used as both the controller and disconnecting means if it a. opens all ungrounded conductors as required by NEC 430.103 b. is protected by an overcurrent device in each ungrounded conductor c. is manually operable, or both power and manually operable d. All of these answersarrow_forwardWhat assumptions can you make regarding the following receptacle wiring? Check all that apply. White neutral wire Grounding screw Brass screw terminal Silver screw terminal Black hot wire Red hot wire Grounding wires Grounding screw terminal O device is at end-of-run device box does not need a ground connection this is a split-circuit receptacle neutral side receptacle tab must be removedarrow_forwardPlease answer all questions , and give me a sample answers 1- What is done to prevent a plan from becoming confusing because of too much detail? 2. Does compliance with the NEC always result in an electrical installation that is adequate, safe, and efficient? Why? 3. Name two nationally recognized testing laboratories. 4- Are low-voltage systems totally safe? Explain 5- Explain briefly what an arc flash is 6- Where might you obtain information about on-the-job safety and safety training?arrow_forward
- 2. When working on a high - voltage system , it is best to keep anyone who is not part of the ser vice away from you and the car by creating a buffer zone around the car . Technician A makes sure the outside edges of the zone are at least one foot away from the car . Technician B places B orange cones to define the outer boundaries of the zone. Who is correct ?arrow_forward9. What is the main function of the fuse? 10. How are load switches classified? 11. What is the purpose of the load switch? Why do load switches are often used with fuses?arrow_forwardladder diagram for three circuits, circuit A is one lampholder and one duplex receptacle controlled by a single pole switch, circuit B is a single pole switch controlling the top half of a duplex receptacle that when energized, is indicated by a pilot light at the single pole switch location plus an isolated ground duplex receptacle that is always hot, circuit C is the bottom half of the switched receptacle on circuit B is to be always hot plus another duplex receptacle that is controlled from two locations using coast 3-way wiring system two circuits are 3-wire multiwire branch circuitarrow_forward
- QUESTION-3: In the system with open and closed protection zones given in the figure below: a) Which breakers will open for fault at point F1? 5) For a fault at point F2, if B3 fails to operate, which breakers should be operated to provide Dack-up protection? B3 F2 BS F1 B1 B2 84arrow_forwardNormally tap changer selection range + or - _____ % in steps of 2.5 %. Three resistors are connected in series with 50, 40, and 20 ohms, connected across a 220 volts supply what is the voltages across 40 ohms resistor? Three resistors are connected in parallel with 50, 40, and 20 ohms, connected across a 220 volts supply what is the current in the 40 ohms resistor? Three resistors are connected in series with 50, 40, and 20 ohms, connected across a 220 volts supply what is the voltages across 20 ohms resistor?arrow_forwardFour-way switches must be wired __________ in a switching circuit that has more than two switching locations. Select one: A. IN LINE WITH THE THREE-WAY SWITCHES B. AFTER THE THREE-WAY SWITCHES C. BEFORE THE THREE-WAY SWITCHES D. BETWEEN THE THREE-WAY SWITCHESarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Why HIGH VOLTAGE DC power Transmission; Author: ElectroBOOM;https://www.youtube.com/watch?v=DFQG9kuXSxg;License: Standard Youtube License