Textbook Question
Chapter 29, Problem 10R
Why is it permissible to omit an electric space heater, water heater, and certain other 240-volt equipment when calculating the neutral service-entrance conductor for a residence? ____
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
4.a. The ___ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total
4.b. What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight
4.c. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.
Airframe Electrical System
Question: What is the maximum acceptable voltage drop from the voltage source to the utilization equipment's ground in a 28 volt system?
(Source: FAA AC 43.13-1B/2B)
Generators can be connected to the electrical system of the residence in several ways
(Select all answers that apply)
Group of answer choices
A. permanent generator where the neutral is not switched by the transfer switch
B. portable generator that has the neutral bonded to the frame and is connected to the dwelling electrical system transfer equipment by a flexible cord
C. permanent generator where the neutral is switched by the transfer switch
D. portable generator that has the neutral isolated or floated from the frame and is connected to the dwelling electrical system transfer equipment by a flexible cord
Chapter 29 Solutions
Electrical Wiring Residential
Ch. 29 - Prob. 1RCh. 29 - a. What is the unit load per ft2 for the general...Ch. 29 - a. What is the ampere rating of the circuits that...Ch. 29 - Why is the air-conditioning load for this...Ch. 29 - What demand factor may be applied when four or...Ch. 29 - What load may be used for an electric range rated...Ch. 29 - What is the calculated load for an electric range...Ch. 29 - What is the calculated load when fixed electric...Ch. 29 - On what basis is the neutral conductor of a...Ch. 29 - Why is it permissible to omit an electric space...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
3.3 It is known that a vertical force of 200 lb is required to remove the nail at C from the board. As the nail...
Vector Mechanics for Engineers: Statics
17–1C A high-speed aircraft is cruising in still air. How does the temperature of air at the nose of the aircra...
Thermodynamics: An Engineering Approach
How are relationships between tables expressed in a relational database?
Modern Database Management
Assume a telephone signal travels through a cable at two-thirds the speed of light. How long does it take the s...
Electric Circuits. (11th Edition)
Why is the study of database technology important?
Database Concepts (8th Edition)
What types of polymers are most commonly blow molded?
Degarmo's Materials And Processes In Manufacturing
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A residential air-conditioning unit is installed in the attic. a. Is a lighting outlet required? __________ b. What Code section applies? __________ c. If a lighting outlet is required, how shall it be controlled? __________ d. What Code section applies? __________ e. Is a receptacle outlet required? __________ f. What Code section applies? __________arrow_forwardAll answers should be written in complete sentences. Calculations should be shown in detail, and Codereferences should be cited when appropriate. Unless otherwise stated, all conductors are copper type THHN, and the supply is AC. 1. What is the minimum conductor size, overload protection, and inverse-time circuitbreaker rating for a circuit supplying a 230-volt, 3-phase, code A, 40°C, 75-horsepower synchronous motor operating at an 80% power factor with a nameplate full-load current of 185 amperes?arrow_forward2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forward
- 9. How is equipment containing ungrounded electrical systems required to be marked? A. With green wiresB. With a sign reading "Caution: Ungrounded System Operating at _______ Volts Between Conductors" C. With a red X D. With a sign reading "Danger: Do Not Touch Ungrounded System, Operating at _______ Volts"arrow_forwardb) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to electrical distribution on board ship. c) Explain with sketches why it is necessary that a single ground fault in an insulated-earth distribution system must be located and cleared immediatelyarrow_forward27. In addition to installation rules, the NEC® is concerned with the ____. Select one: A. TYPES OF INSTALLATION METHODS B. ELECTRICAL CONTRACTOR LICENSING REQUIREMENTS C. SUPERVISING AGENCY D. TYPE AND QUALITY OF ELECTRICAL WIRING SYSTEM MATERIALSarrow_forward
- - Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durabilityarrow_forwardReceptacles that provide power for a spa or hot tub shall be ________. Select one: a. AFCI-protected b. twist-lock c. ground-fault circuit-interrupter protected d. both B and Carrow_forward15. The Philippine Electrical Code (PEC) is intended for ____ applications by government bodies exercising legal jurisdiction over electrical installation. a. Advisory b. Mandatory c. Optional d. Not neededarrow_forward
- A device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forward45. A switch or circuit breaker can be used as both the controller and disconnecting means if it a. opens all ungrounded conductors as required by NEC 430.103 b. is protected by an overcurrent device in each ungrounded conductor c. is manually operable, or both power and manually operable d. All of these answersarrow_forwardIn a 10-trunk circuit, there are 180 calls in one hour. The average holding time per call is 2 minutes. Calls that fail to seize a circuit are immediately dropped. If approximately 20% of the calls retry after failing to seize the circuit, determine the GoS. (Use of calculator is allowed)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License