Question
Chapter 28, Problem 28.6QAP
Interpretation Introduction
Interpretation:
The meaning of the linear response range of the detector is to be stated.
Concept introduction:
The response of a detector with respect to the concentration of the analyte is the response range of a detector. The response of a detector is called linear when the difference in response of two concentrations of a compound is proportional to the individual difference in the concentration of two different samples. If the
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
are there any points within the linear
range of a signal response curve that
cannot be used to determine the
concentration of analyte in a sample?
What is the relationship between chemical shift in ppm and operating frequency?
What is the significance of the max of a
spectrum?
What are the other uses of the
spectrophotometer?
Chapter 28 Solutions
Principles of Instrumental Analysis
Ch. 28 - Prob. 28.1QAPCh. 28 - Prob. 28.2QAPCh. 28 - Prob. 28.3QAPCh. 28 - How can the selectivity factor be manipulated in...Ch. 28 - Prob. 28.5QAPCh. 28 - Prob. 28.6QAPCh. 28 - Prob. 28.7QAPCh. 28 - Prob. 28.8QAPCh. 28 - Prob. 28.9QAPCh. 28 - Prob. 28.10QAP
Ch. 28 - Prob. 28.11QAPCh. 28 - Prob. 28.12QAPCh. 28 - Prob. 28.13QAPCh. 28 - Prob. 28.14QAPCh. 28 - Prob. 28.15QAPCh. 28 - Prob. 28.16QAPCh. 28 - Mass spectrometry is an extremely versatile...Ch. 28 - Prob. 28.18QAPCh. 28 - Prob. 28.19QAPCh. 28 - Two components in an HPLC separation have...Ch. 28 - Prob. 28.21QAPCh. 28 - Prob. 28.22QAPCh. 28 - Prob. 28.23QAP
Knowledge Booster
Similar questions
- The levels of Vitamin B1 in a sample of milk was determined using the Standard Addition method and technique of fluorescence spectroscopy. 18.0 ml of the milk sample was diluted to 20.0 ml using distilled water and then the fluorescence was measured. The resulting signal was 210 units. A spike was made by taking 18.0 ml of the same milk sample, adding 1.0 ml of a 6.0 ppm Vitamin B1 standard solution, and then diluting to 20.0 ml using distilled water. The signal of the spiked milk was 540 units. Calculate the concentration of Vitamin B1 in the original milk sample (in ppm). Report to 3 decimal places.arrow_forwardExplain why the information from an XPS chemical shift must also be contained in an X-ray absorption edge.arrow_forwardSuppose a student is preparing a set of standard solutions for use in a spectrophotometric study. If percent transmittance, %T, were measured in the standard solutions before the color had a chance to fully develop, the measured value would be compared with solutions that have allowed the color to fully develop.arrow_forward
- A 600 MHz NMR has a signal to noise ratio of 1000 for a proton standard. The 400 MHz NMR has a signal to noise ratio of 200 for a proton standard. If it takes 20 minutes to get an acceptable signal to noise ratio for a sample on the 600 MHz NMR, how long will it take you to achieve the same signal to noise ratio on the 400 MHz NMR?arrow_forwardIf two signals differ by 90 Hz in a 300 MHz spectrometer, by how much do they differ in a 500 MHzspectrometer?arrow_forwardAn analyst needs to evaluate the potential effect of an interferent, I, on the quantitative analysis for an analyte, A. She begins by measuring the signal for a sample in which the interferent is absent and the analyte is present with a concentration of 15 ppm, obtaining an average signal of 23.3 (arbitrary units). When analyzing a sample in which the analyte is absent and the interferent is present with a concentration of 25 ppm, she obtains an average signal of 13.7.arrow_forward
- An analyst needs to evaluate the potential effect of an interferent, I, on the quantitative analysis for an analyte, A. She begins by measuring the signal for a sample in which the interferent is absent and the analyte is present with a concentration of 15 ppm, obtaining an average signal of 23.3 (arbitrary units). When analyzing a sample in which the analyte is absent and the interferent is present with a concentration of 25 ppm, she obtains an average signal of 13.7. What is the sensitivity for the analyte? What is the sensitivity for the interfering? What is the value of the selectivity coefficient? What is the maximum concentration of interferent relative to that of the analyte (i.e. interferent/analyte), if the error in the analysis is to be less than 1%?arrow_forwardDIfference between different types of UV spectrometers based on their advantages and disadvantagesarrow_forwardThe chemical shift value (δ) is measured by the ratio of shift in Hertz and the operational frequency of the spectrometer in MHz, give the equation to calculate the shift valuearrow_forward
- y If y = 36 and x = 6, what is the signal-to-noise ratio?arrow_forwardIf two signals differ by 1.5 ppm in a 300 MHz spectrometer, by how much do they differ in a 500 MHz spectrometer?arrow_forwardExplain why an internal standard is required during sample preparation in quantitative analysis when using atomic spectroscopy?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning