(a)
Interpretation:
The effect of increasing the mass of stationaryphase relative to the packing masson the plate height needs to be explained.
Concept introduction:
As the number of plates increases in a GC column, the resolution would also increase. For increasing the number of plates, the height of the plates has to be decreased for maintaining a high resolution. The van Deemter equation is used for defining the effect of different parameters on the height of plate.
(b)
Interpretation:
The effect of decreasing the rate of sample injection on the plate height needs to be explained.
Concept introduction:
The resolution will increase as the number of plates increases in the GC column. For maintaining a high resolution and increasing the number of plates, the height of the plates must be decreased. For defining the effect of different parameters on the height of plate, van Deemter equation is used.
(c)
Interpretation:
The effect of increasing the injection port temperature on the plate height needs to be explained.
Concept introduction:
In GC column resolution will increases as the number of plates increases.For maintaining a high resolution and increasing the number of plates, the height of the plates has to be decreased. For defining the dependencies of various parameters on the height of plate, van Deemter equation is used.
(d)
Interpretation:
The effect of increasing the flow rate on the plate height needs to be explained.
Concept introduction:
As the number of plates increases in a GC column, the resolution would also increase. For increasing the number of plates, the height of the plates has to be decreased for maintaining a high resolution. The van Deemter equation is used for defining the effect of different parameters on the height of plate.
(e)
Interpretation:
The effect of reducing the particle sizeof the packing on the plate height needs to be explained.
Concept introduction:
The resolution will increase as the number of plates increases in the GC column. For maintaining a high resolution and increasing the number of plates, the height of the plates must be decreased. For defining the effect of different parameters on the height of plate, van Deemter equation is used.
(f)
Interpretation:
The effect of decreasing the column temperature on the plate height needs to be explained.
Concept introduction:
In GC column resolution will increases as the number of plates increases. For maintaining a high resolution and increasing the number of plates, the height of the plates has to be decreased. For defining the dependencies of various parameters on the height of plate, van Deemter equation is used.
Trending nowThis is a popular solution!
Chapter 27 Solutions
Principles of Instrumental Analysis, 6th Edition
- Draw a Newman projection from carbon 3 to carbon 2 in the highest energy conformation for the following molecule. What is this conformation called? What kind of strain is present? Brarrow_forwardWhich of the following dienophiles is most reactive in a Diels-Alder reaction: Please explain why the correct answer to this question is option 5. Please provide a detailed explanation.arrow_forwardWhich of the following would you expect to be aromatic? Please provide a detailed explanation.arrow_forward
- Draw the enantiomer and diastereomers of the following molecule. Label each type of stereoisomers. Label each chiral center as R or S. HOarrow_forwardWhich diene and dienophile would you choose to synthesize the following compound? Please provide a detailed explanation. Please include a drawing showing the mechanism of the synthesis. Please also explain why it is the correct diene and dienophile.arrow_forwardUsing the sketcher below, draw the structure of N-ethyldecylamine. Answer: 0 ୨୫) . 始 {n [ ]t ?arrow_forward
- Which of the following would you expect to be aromatic? Please provide a detailed explanation.arrow_forwardIdentify the characteristic signals that you would expect in the diagnostic region of an IR spectrum of each of the following compounds. a. H₂N b.arrow_forwardWhat is the lowest energy chair for the following cyclohexane? ' || || a. b. " " d.arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning