Textbook Question
thumb_up100%
Chapter 26, Problem 26.17QAP
From the data in Problem 26-14, calculate for species C and D)
(a) the resolution.
(b) the length of column necessary to separate the two species with a resolution of 2.5.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Why are collision cells a necessary addition to mass spectrometers that employ electrospray ionisation for small molecule structure characterisation?
(a) Three components in a mixture have varying distribution constants between the mobile phase and the stationary phase. One of the components has a very high distribution constant. Would this component likely elute first or last and how would you design an experiment or modify the components of the separation to make it perform in the opposite manner?
(b) One way to dramatically increase the sensitivity of a quadrupole mass spectrometer is to use a technique called selected ion monitoring (SIM). Explain how this technique works and why it improves sensitivity. Explain what dwell time means. Be sure to draw a diagram and describe how this analysis scheme works. Also, is there a compromise between a wide range of masses scanned and SIM? Explain in easy details.
Calculate the absorbance at 280 nm that is expected for a 17 microM solution of peptide GRAYISH, if a 10-cm cuvette is used. For the extinction coefficient, take into account that e280(Trp) = 5690 M-1 cm-1 and e280(Tyr) = 1280 M-1 cm-1.
Chapter 26 Solutions
INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<
Ch. 26 - Prob. 26.1QAPCh. 26 - Prob. 26.2QAPCh. 26 - Prob. 26.3QAPCh. 26 - Prob. 26.4QAPCh. 26 - Prob. 26.5QAPCh. 26 - Prob. 26.6QAPCh. 26 - Prob. 26.7QAPCh. 26 - Prob. 26.8QAPCh. 26 - Prob. 26.9QAPCh. 26 - Prob. 26.10QAP
Ch. 26 - Prob. 26.11QAPCh. 26 - Prob. 26.12QAPCh. 26 - Prob. 26.13QAPCh. 26 - Prob. 26.14QAPCh. 26 - Prob. 26.15QAPCh. 26 - Prob. 26.16QAPCh. 26 - From the data in Problem 26-14, calculate for...Ch. 26 - Prob. 26.18QAPCh. 26 - Prob. 26.19QAPCh. 26 - Prob. 26.20QAPCh. 26 - Prob. 26.21QAPCh. 26 - Prob. 26.22QAPCh. 26 - Prob. 26.23QAP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- A molecular exclusion column has a diameter of 7.8 mm and a length of 30 cm. The solid portion of the particles occupies 20% of the volume, the pores occupy 40%, and the volume between particles occupies 40%. (a) At what volume would totally excluded molecules be expected to emerge? (b) At what volume would the smallest molecules be expected? (c) A mixture of polymers of various molecular masses is eluted between 23 and 27 mL. What does this imply about the retention mechanism for these solutes on the column?arrow_forwardi) Find the differences between the AES and XPS in terms of principle and information obtained from the spectra. ii) Why AFM is mostly utilized microscopic method for the determination of the thickness of the film?arrow_forwardIron nanoparticles were produced by the evaporation method and their average sizes are estimated 25,50, 90 and 120 nm using the laser particle analyzer. Assuming that the resultant particles are strain freeand the peak broadening detected in the measurement with Cu-K radiation (λ=0.154 nm) arises onlyfrom variation of size of the crystallites, estimate the peak width (the value of FWHM) of the (110) plane.arrow_forward
- Calculate the molar extinction coefficient (e) of a molecule at a particular wavelength given that a 0.000764 M solution of the molecule produced a fluorescence intensity (I) of 1177 when the irradiance of the beam incident to the sample (Po) was 821 and the length of the medium (b) was 1.12 cm. The proportionality constant k' for this molecule is 0.319. € = ×10 TOOLS M-1.cm-1arrow_forwardFor a tungsten carbene (catalyst) binding to THF (ligand) at 25 oC in per-deuterotoluene solvent, the chemical shift of the unbound catalyst alpha hydrogen was determined to be 794.6 Hz and the peak for the fully bound catalyst alpha hydrogen was observed at 842.4 Hz. Furthermore, the binding constant (or formation constant) Kf was found to be 15.40 M-1. Given the following initial concentrations of catalyst and ligand, calculate the percent THF bound you would expect to see at 25 oC. Record your answer to the nearest tenths of a percent, as a number with no units (Ex. 3.4% ----> enter "3.4") Co = 1.000 M Lo = 0.1000 Marrow_forwardExactly 5.00 mL aliquots of a solution containing analyte X were transferred into 50.00-mL volumetric flasks and the pH of the solution is adjusted to 9.0. The following volumes of a standard solution containing 2.00 µg/mL of X were then added into each flask and the mixture was diluted to volume: 0.000, 0.500, 1.00, 1.50 and 2.00 mL. The fluorescence of each of these solutions was measured with a fluorometer, and the following values were obtained: 3.26, 4.80, 6.42, 8.02 and 9.56, respectively. ii. Using relevant functions in Excel, derive a least-squares equation for the data, and use the parameters of this equation to find the concentration of the phenobarbital in the unknown solution.arrow_forward
- 7) A 25.0 ml sample containing Cu gave an instrument reading of 23.6 units (corrected for a blank). When exactly 0.500 ml of 0.0287M Cu(NO3)2 Was added to the solution,the signal increased to 37.9 units. Calculate the molar concentration of Cu" in the sample +2,arrow_forward(a) You measure the percent transmittance of a solution containing chromophore X at 400nm in a 1-cm path length cuvette and find it to be 50%. What is the absorbance of this solution? (b) What is the molar absorptivity of chromophore X if the concentration of X in the solution measured in question (a) is 0.5mM? (c) What is the concentration range of chromophore X that can be assayed if, when using a sample cell of path length 1, you are required to keep the aborbance between 0.2 and 0.8?arrow_forward2. Answer ALL parts. (a) The absorbance of compound A was measured in a 1.00 cm cuvette at 238 nm. A 3.96 x 10 M solution of compound A exhibited an absorbance of 0.624. A blank solution containing only the solvent had an absorbance of 0.029 at the same wavelength. Calculate the molar absorptivity of compoundA in m' mole". (i) The absorbance of an unknown solution of Compound A in the same solvent and cuvette was 0.375 at 238 nm. Find the concentration of A in the unknown. (iii) A concentrated solution of Compound A in the same solvent was diluted from an initial volume of 2.00ml to a final volume of 25 ml and then had an absorbance of 0.733 under the same conditions. What is the concentration of A in the concentrated solution? (iv) What type of cuvette was used in the above analysis? Justify your answer. (b) Name ONE advantage and ONE disadvantage of a linear photodiode array detector compared to a traditional photomultiplier based spectrometer. (c) Why is an FTIR spectrum digital in…arrow_forward
- An atomic beam is designed to function with (a) cadmium, (b) mercury. The source is an oven maintained at 380K with a small slit of dimensions 1.0cm x 1.0 x 10-3cm. The vapor pressure of cadmium is 0.13 Pa nd that of mercury is 12 Pa at this temperature. What is the atomic current (the number of atoms per second) in the beams?arrow_forward0.35 μΜ Determine the molar absorptivity of has an absorbance of 0.42 at 610 nm in a 3.000-cm cell. 4.00×105 M¹ cm¯¹ -1 4.0×106 M¹ cm -1 4.0×105 M¹ cm -1 4.0×10³ M¹ cm -1 dichromate solution whicharrow_forward(2) Adenine has a molar absorbance of 4 13.1 M-1cm-1 for 263 nm nucleic acid. What is the molar concentration of an acid solution that shows a permeability of 75% when 2 ml of it is placed in an absorption cell with a thickness of 1 cm?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Mass Spectrometry; Author: Professor Dave Explains;https://www.youtube.com/watch?v=hSirWciIvSg;License: Standard YouTube License, CC-BY