EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 26, Problem 12R
An important but often overlooked requirement in the National Fire Alarm Code, NFPA 72 is that alarms must be replaced after being in service for (circle the correct answer)
- a. not more than 5 years.
- b. not more than 10 years.
- c. not more than 15 years.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Is it required to use a PMMC instrument in an Instrument
transformer based measurement system?
a. No, not required
b. Yes,required
c. Can't be said
d. It is optional
Please answer quickly.
17. The filament of incandescent lamp is usually made of:
a. copper
b. silver
c. aluminum
d. tungsten
18. A current measuring instrument can be modified to measure voltages by:
a. using thicker wire in the coil
b. using a high resistance shunt
c. adding resistance in series
d. adding resistance in parallel
21. "When two power sources are connected in a series-aiding configuration, the output voltage equals the _____________"
a. supply with the highest voltage
b. supply with the lowest voltage
c. difference of the two supplies
d. sum of the two supplies
36. Electrical explosions directly into the face of a person working on or near energized
electrical equipment can and will cause serious injury or death. OSHA laws and NFPA
70E have strict safety requirements for working on electrical equipment. The basic rules
are to turn off the power before working on the equipment and to wear the proper type of
nonflammable clothing. To further provide safety for the worker, the National Electrical
Code has a requirement pertaining to arc-flash hazard warning. This requirement is
found in
a. 110.16 (A)
b. 220.1
of the NEC
C. 330.1
d. 410.5
Chapter 26 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 26 - In your own words, explain the terms alarm and...Ch. 26 - The requirements for household fire alarm systems...Ch. 26 - Do heat alarms and carbon monoxide alarms take the...Ch. 26 - Name two basic ways that smoke alarms are powered.Ch. 26 - Name the two types of smoke alarms.Ch. 26 - List the absolute minimum level of smoke alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Prob. 10R
Ch. 26 - Prob. 11RCh. 26 - An important but often overlooked requirement in...Ch. 26 - Carbon monoxide is ____________, and is...Ch. 26 - Circle the correct answer from the following...Ch. 26 - The wiring of more complex household fire alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Fire alarm cable generally used in more complex...Ch. 26 - When installing a fire alarm system or a complete...Ch. 26 - Residential sprinkler fire protection systems are...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The requirements for household fire alarm systems are found in what NFPA Code and in what chapter of this Code?arrow_forwardWhich statement is not true about the Ground Fault Circuit-Interrupter (GFCI): Select one: O a. The device is used in many places around the world to reduce electric shock that involves electric appliances and water occur every year. O b. Both answers are incorrect O. AGFCI outlet has a special internal device that trips out if an imbalance on the phase and neutral occurs The output of a thyristor rectifier is uncontrollable dc voltage Select one: O a. False O b. Truearrow_forward5- An instrument is used for lowering the value of voltage for measuring and protection is a. Circuit breaker b. Protection relay c. Isolator d. Current transformer e. Potential transformer 6- are the protective devices used for protection of equipment from lightning strokes a. Isolators b. Lighting arrestors c. Busbars d. Fuses e. Wave trap 7- The range of voltages between 1KV to 35kV is classified as: a. Low voltage b. Medium voltage c. High voltage d. Extra high voltage e. Ultra high voltagearrow_forward
- I have a wooden toy train that runs on wooden tracks. I would like to place two ESP-WROOM-32 Boards on top of the train. Broadcast communication (which involves radio frequency, not Wi-Fi) would help communicate about the train's lateness to five other wooden trains on the same track. Local communication would help communicate to the train station about the train's lateness. I would also need radio frequency Tx-Rx Modules for discharging and undergoing the signal, and repeaters just in case the signal loses power due to long-distance traveling. My wooden train should be automated. It should run at 4 inches per second, keep a minimum distance of 30 seconds away from the other wooden trains, and make a 17-second-long stop every 500 seconds. What's the procedure to connect the components? What's the Arduino code (C++) for this project?arrow_forwardPlease answer all questions , and give me a sample answers 1- What is done to prevent a plan from becoming confusing because of too much detail? 2. Does compliance with the NEC always result in an electrical installation that is adequate, safe, and efficient? Why? 3. Name two nationally recognized testing laboratories. 4- Are low-voltage systems totally safe? Explain 5- Explain briefly what an arc flash is 6- Where might you obtain information about on-the-job safety and safety training?arrow_forwardHow would you design a fuse protection system? Choose the right answer with justification: a) protect both PLCS with the same set of fuses, OR b) separate the fuse protection for each PLCarrow_forward
- Draw the basic building blocks of the following systems. Explain briefly the operation/function(s) of each block in your system. Recommend probable integrated circuits to be used per operation/function(s) in your system. 1. A system that will monitor and control the level of water in a dam. 2. A system that will switch ON the AC power generator as soon as the main AC source is OFF. Switch OFF the AC power generator when the main AC power is ON.arrow_forwardQuestion 1 a) Prepare the specific requirements which ought to taken into consideration when developing an Electrical Power System Protection Scheme b) Evaluate five qualities of an Electrical power Protective System if you were to be hired to conduct an assessment as a protection engineer. c) Enumerate five fundamental Components in a typical Electrical Power system Protection and explain their functions. d) As an Electrical engineer who is contracted for an electrical system installation write five considerations in determining your fuse rating.arrow_forward1. Outline/Give Two examples for job factors that could lead to poor/bad health and safety behaviour in the workplace? 2. Give thegning limit FB 3. Me 0 4. Before repair work or maintenance of electrical equipment and devices is started, WHAT steps are necessary to undertake to have maximum electrical safety? 5. What power tool is most likely to cause a burn hazard? END Scanned by Candcasearrow_forward
- Please explain detail, Thank you List and explain types of Fire Extinguishers. What's the difference between Mechanical safety vs. Electrical safety Key Term: MSDS Key Term: Chemical spillarrow_forwardWhich of the following statements is true for an SCR. O A. It is an on-only controllable switch, which is turned on by a gating signal and cannot be turned off externally; only system conditions can turn off the device once it is on O B. None of the other choices are correct O C. It is a controllable switch, which is turned on by applying a gating signal and is turned off when the gating is removed O D. It is an off-only controllable switch, which is turned off by a gating signal as needed O E. It is an on-off controllable switch, which is turned on and off by a gating signal as neededarrow_forwardappropriate answer. Statement one The most common causes of death are falls from heights and being struck by vehicles in the workplace Statement two Following HSE guidance should significantly reduce the risk to an individual a) Statement one is correct and statement two is correct b) Statement two is correct and statement one is incorrect c) Both statements are incorrect d) Statement one is correct and statement two is incorrect actclass.co.uk 25 Questi 26 Questi 27 Questi 28 Questi 29 Questi 30 Submit Answersarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License