Refer to the formulas in the Resistive-Capacitive Series Circuits Formula section of Appendix B and to Figure 22-1.
Assume that the circuit shown in Figure 22–1 is connected to a 480-V, 61-Hz line. The capacitor has a capacitance of 165.782 µF, and the resistor has a resistance of 12 Ω. Find the missing values.
ET 480 V ________ | ER _____________ | EC ________________ |
ET 480 V ________ | ER _____________ | EC ________________ |
Z ________________ | R 12 Ω _________ | XC _________________ |
VA _______________ | P _____________ | VARsC ______________ |
PF _______________ | ∠θ ______________ | C 16.782 µF __________ |
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
-calculate theoretical voltage and current values in Figure 1.3 and record them in Table 1.1. Calculate-all-
voltage and current values as peak-to-peak.
Table 1.1: Calculated Values of RC-Circuit
ZTotale
in (p-to-p)¤
VR-(p-to-p)¤
Vc-(p-to-p)¤
R(2) X-(2) mag (mA) angled mag (V) angled mag-(V) angle
Freq. (Hz) X (N)-
ρα
ρα
500x
4000x
ρα
ρα
ρα
ρα
ρα
ρα
ρα
ρα
Q1 .Determine the model of the following system using Mason's rule
A three-phase delta-connected load, each phase of which
has an inductive reactance of 40 Ω and a resistance
of 25 Ω, is fed from the secondary of a three-phase
star-connected transformer which has a phase voltage
of 230 V. Draw the circuit diagram of the system and
calculate: (a) the current in each phase of the load; (b)
the p.d. across each phase of the load; (c) the current
in the transformer secondary windings; (d) the total
active power taken from the supply and its power factor.
ANS= 8.8 A, 416 V, 15.25 A, 5810 W
Chapter 22 Solutions
DELMAR'S STANDARD TEXT OF ELECTRICITY
Ch. 22 - In a pure capacitive circuit, does the current...Ch. 22 - A series circuit contains a 20- resistor and a...Ch. 22 - An RC series circuit has a power factor of 76%....Ch. 22 - An RC series circuit has a total impedance of 84 ....Ch. 22 - A capacitor has a capacitive reactance of 50 when...Ch. 22 - A 15-F AC capacitor is connected in series with a...Ch. 22 - An RC series circuit is connected to a 120-V,...Ch. 22 - An RC series circuit is connected to a 240-V,...Ch. 22 - Refer to the formulas in the Resistive-Capacitive...Ch. 22 - Assume that the voltage drop across the resistor,...
Ch. 22 - Assume the circuit shown in Figure 221 has an...Ch. 22 - Assume the circuit in Figure 22-1 has a power...Ch. 22 - In a series RC circuit, ET=240 volts, R=60, and...Ch. 22 - In a series RC circuit, ET=120 volts, R=124, and...Ch. 22 - In a series RC circuit, ET=208 volts, IT=2.4...Ch. 22 - In a series RC circuit, ET=460 volts and =44. Find...Ch. 22 - In a series RC circuit, ET=240 volts at 60 Hz. An...Ch. 22 - In a series RC circuit, the apparent power is 4250...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- "I need something clear written by hand with steps." Find Laplace transform and the corresponding ROC for x(t) = e−3sin(2t) u(t)dtarrow_forwardThree similar coils, connected in star, take a total power of 1.5 kW, at a power factor of 0.2, from a three-phase, 400 V, 50 Hz supply. Calculate: (a) the resistance and inductance of each coil; (b) the line currents if one of the coils is short-circuited.arrow_forward(a) Three 20 µF capacitors are star-connected across a 400 V, 50 Hz, three-phase, three-wire supply. Calculate the current in each line. (b) If one of the capacitors is short-circuited, calculate the line cur rents. (c) If one of the capacitors is open-circuited, calculate: the line currents and the p.d. across each of the other two capacitors. ANS: 1.525 A; 2.64 A, 2.64 A, 4.57 A; 1.32 A, 1.32 A, 0; 210 Varrow_forward
- Explain the advantages of three-phase supply for distribution purposes. (b) Assuming the relationship between the line and phase values of currents and voltages, show that the active power input to a three-phase balanced load is √3VI cos φ, where V and I are line quantities. (c) Three similar inductors, each of resistance 10 Ω and inductance 0.019 H, are delta-connected to a three-phase, 400 V, 50 Hz sinusoidal supply. Calcu late: the value of the line current; the power factor and the active power input to the circuit. ANS: 59.5 A, 0.858 lag, 35.5 kWarrow_forwardnot use ai pleasearrow_forwardA three-phase, 400 V, star-connected motor has an output of 50 kW, with an efficiency of 90 per cent and a power factor of 0.85. Calculate the line current. Sketch a phasor diagram showing the voltages and currents. If the motor windings were connected in mesh, what would be the correct voltage of a three phase supply suitable for the motor? ANS: 90.8 A, 240 Varrow_forward
- Don't use ai to answer I will report you answerarrow_forwardShow with the aid of a phasor diagram that for both star- and delta-connected balanced loads, the total active power is given by √3VI cos φ, where V and I are the line values of voltage and current respectively and φ is the angle between phase values of voltage and current. A balanced three-phase load consists of three coils, each of resistance 4 Ω and inductance 0.02 H. Determine the total active power when the coils are (a) star-connected, (b) delta-connected to a 400 V, three phase, 50 Hz supply. ANS:11.56 kW, 34.7 kWarrow_forwardThe load connected to a three-phase supply comprises three similar coils connected in star. The line currents are 25 A and the apparent and active power inputs are 20 kVA and 11 kW respectively. Find the line and phase voltages, reactive power input and the resistance and reactance of each coil. If the coils are now con nected in delta to the same three-phase supply, calculate the line currents and the active power taken. ANS : 462 V, 267 V, 16.7 kvar, 5.87 Ω, 8.92 Ω; 75 A, 33 kWarrow_forward
- A three-phase delta-connected load, each phase of which has an inductive reactance of 40 Ω and a resistance of 25 Ω, is fed from the secondary of a three-phase star-connected transformer which has a phase voltage of 230 V. Draw the circuit diagram of the system and calculate: (a) the current in each phase of the load; (b) the p.d. across each phase of the load; (c) the current in the transformer secondary windings; the total active power taken from the supply and its power factor.arrow_forwardDerive the numerical relationship between the line and phase currents for a balanced three-phase delta connected load. Three coils are connected in delta to a three-phase, three-wire, 400 V, 50 Hz supply and take a line current of 5 A 0.8 power factor lagging. Calculate the resistance and inductance of the coils. If the coils are star-connected to the same supply, calculate the line current and the total power. Calculate the line cur rents if one coil becomes open-circuited when the coils are connected in star. Ans: 110.7 Ω, 0.264 H; 1.67 A, 926 W; 1.445 A, 1.445 A, 0arrow_forwardDerive, for both star- and delta-connected systems, an expression for the total power input for a balanced three-phase load in terms of line voltage, line current and power factor. The star-connected secondary of a transformer supplies a delta-connected motor taking a power of 90 kW at a lagging power factor of 0.9. If the volt age between lines is 600 V, calculate the current in the transformer winding and in the motor winding. Draw circuit and phasor diagrams, properly labelled, showing all voltages and currents in the transformer secondary and the motor. ANS: . 96.2 A, 55.6 Aarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electrical Measuring Instruments - Testing Equipment Electrical - Types of Electrical Meters; Author: Learning Engineering;https://www.youtube.com/watch?v=gkeJzRrwe5k;License: Standard YouTube License, CC-BY
01 - Instantaneous Power in AC Circuit Analysis (Electrical Engineering); Author: Math and Science;https://www.youtube.com/watch?v=If25y4Nhvw4;License: Standard YouTube License, CC-BY