Concept explainers
You are an electrician installing the wiring in a new home. The homeowner desires that a ceiling fan with light kits be installed in five different rooms. Each fan contains a light kit that can accommodate four 60-watt lamps. Each fan motor draws a current of 1.8 amperes when operated on high speed. It is assumed that each fan can operate more than three hours at a time and therefore must be considered a continuous-duty device. The fans are to be connected to a 15-ampere circuit. Because the devices are continuous-duty, the circuit current must be limited to 80% of the continuous connected load. How many fans can be connected to a single 15-ampere circuit? How many circuits will be required to supply power to all five fans?
Trending nowThis is a popular solution!
Chapter 2 Solutions
Delmar's Standard Textbook Of Electricity
- Two 115-V incandescent lamps A & B are connected in series across 230-V dc source. Lamp A is rated 100 W and lamp B is rated 60 W. Which lamp is abnormally bright and hence will burn out soon? a) Lamp A b) Lamp B c) Both lamps will be abnormally bright d) Both lamps will work normally O a. Lamp A O b. Lamp B O c. Both lamps will be abnormally bright O d. Both lamps will work normallyarrow_forwardQUESTION 5 We would like to run the power wires for both cooling pumps in the same RMC from the Breaker panel to a junction box above the control panel. What size ungrounded conductors do we need for the 100 amp load? All conductors have typeTHHN insulation. A #6 AWG B #3 AWG C #4 AWG D #1 AWGarrow_forwardWhile discussing the DC-DC converter used in most hybrids : Technician A says that it changes some of the DC voltage from the battery module to an AC voltage for the electric motors . Techni cian B says that it provides the power to oper ate the car's 12 -volt electrical system and accessories . Who is correct ?arrow_forward
- Please help me solve questions 1-5 using the given values found.arrow_forwardAn AC ammeter has a direct reading 0-600A scale when used with a 400:3 ratio current transformer. The ammeter is now used with a 1,000:3 ratio current transformer. What should be the ammeter reading when the actual current is 3 A. use four decimal places if necessary.arrow_forwardTwo heating units A and B are connected parallel across a 240-volt supply. Unit B takes thrre-times as much power in A, and the total power is 2400 Watts. Determine resistances of A and B.arrow_forward
- There are three 15,000-ohm resistors connected in series across a 120-volt DC source. What is the voltage distribution across each resistor? What would be the voltage reading across the first resistor if a 0-120 volt meter with a 100-ohm per volt sensitivity is used? What would be the voltage reading across the first resistor if a 0-120 volt meter with a 10,000 ohm per volt sensitivity is used?arrow_forwardTwo 115-V incandescent lamps A & B are connected in series across 230-V de source. Lamp A is rated 100 W and lamp B is rated 60 W. Which lamp is abnormally bright and hence will burn out soon? a) Lamp A b) Lamp B c) Both lamps will be abnormally bright d) Both lamps will work normallyarrow_forwardFor the subtractor, if V2 equals 5 volts DC, and V1 is 4 volts DC, then the O/P is .A The answer is 4 volts DC B The answer is 9 volts DC The answer is 1 volt DC .D The answer is 5 volts DCarrow_forward
- Short circuit is occurred when: Select one: a. The voltage between the two terminals is zero although there may be a nonzero current between the terminals. b. All of the given answers. c. There will be a zero-resistance connection between terminal A and B and therefore the 2 terminals are at the same voltage. d. A pair of terminals connected by a wire (of zero resistance).arrow_forwardWhen there are, into action to prevent instability. in the power system, the voltage regulators will come O Current variations in power system O Oscillations in power system O Voltage variations in power system O Swinging in power systemarrow_forwardCan someone help with these worksheets and let me know if have any incorrect answers? Thank youarrow_forward
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT