Chapter 2, Problem 2.40P

A balanced three-phase 240-V source supplies a balanced three-phase Load. If the line current I A is measured to be 15 A and is in phase with the line-to-line voltage, V BC , find the per-phase load impedance if the load is (a) Y-connected, (b) Δ -conneeted.

Blurred answer
Students have asked these similar questions
Homework: ANOVA Table for followed design Dr B AB -1 -1 1 (15.18,12) 1 -1 -1 (45.48.51) -1 1 -1 (25,28,19) 1 1 (75,75,81)
"I need the solution along with proof of the correct choice by the expert." choose the correct answer 1. The maximum break down strength of air at 76 cm mercury pressure and temperature of 25 °C is...... a. 30 V/cm b. 30 kV/cm c. 300 kV/cm d. Non of them 2. The installed capacity of a power station must be not ....... than the maximum demand. b. equal c. more a. Less 3. Area under the daily load curve divided by 24 hour gives daily d. Non of them a. average load in kW. b. maximum demand in kW. c. units generated in kwh. d. Non of them 4. In thermal power station, 5 kwh need to burn fuel has a. 860 k.calorific. b. 1500 k.calorific c. 4300 k.calorific d. Non of them. 5. Francis and Kaplan turbines are used for... heads. a. medium and high b. medium and low c. medium only. d. High only 6. For photo voltage cell, Fill factor is a. Umpimp Uscise b. Vscisc Vmpimp c. Vmpimp d. Vscisc 7. Power available from wind mill is a. PA V² b. -AV² c. PA V³ d. pA V³ 2p
"I need the solution along with proof of the correct choice by the expert." b. Less than 33Kv c. Greater than 33Kv stored as Pick up the correct option for five only (with the solution if required). 1. Suspension insulator used for transmission and distribution of electric power at a. Up to 33Kv 2. The excess energy from wind power turbine can be chemical energy b. mechanical energy 3. Reaction turbines are used for a. High heads a. b. medium heads 4. More efficient plants are used as d. Not of all c. compressed air d. All of them c. low heads d. low and medium heads. a. base load stations b. peak load stations c. Average load d. All of them 5. Alignment of the blade angle with respect to the wind direction to get maximum wind energy can be achieved with the help of a. Fixed gears b. Yaw motor gear 6. For photo voltage cell, Fill factor using the data: b. 0.59 c. 0.20 c. Control systems d. Blades P-15 W, V-18 V, I-4 A. is d. 0.98 a. 0.65 7. A commercial load is connected to the grid…

Chapter 2 Solutions

MindTap Engineering, 1 term (6 months) Printed Access Card for Glover/Overbye/Sarma's Power System Analysis and Design, 6th

Ch. 2 - The power factor for an inductive circuit (R-L...Ch. 2 - The power factor for a capacitive circuit (R-C...Ch. 2 - Prob. 2.13MCQCh. 2 - The instantaneous power absorbed by the load in a...Ch. 2 - Prob. 2.15MCQCh. 2 - With generator conyention, where the current...Ch. 2 - Consider the load convention that is used for the...Ch. 2 - Prob. 2.18MCQCh. 2 - The admittance of the impedance j12 is given by...Ch. 2 - Consider Figure 2.9 of the text, Let the nodal...Ch. 2 - The three-phase source line-to-neutral voltages...Ch. 2 - In a balanced three-phase Y-connected system with...Ch. 2 - In a balanced system, the phasor sum of the...Ch. 2 - Consider a three-phase Y-connected source feeding...Ch. 2 - For a balanced- load supplied by a balanced...Ch. 2 - A balanced -load can be converted to an...Ch. 2 - When working with balanced three-phase circuits,...Ch. 2 - The total instantaneous power delivered by a...Ch. 2 - The total instantaneous power absorbed by a...Ch. 2 - Under balanced operating conditions, consider the...Ch. 2 - One advantage of balanced three-phase systems over...Ch. 2 - While the instantaneous electric power delivered...Ch. 2 - Given the complex numbers A1=630 and A2=4+j5, (a)...Ch. 2 - Convert the following instantaneous currents to...Ch. 2 - The instantaneous voltage across a circuit element...Ch. 2 - For the single-phase circuit shown in Figure...Ch. 2 - A 60Hz, single-phase source with V=27730 volts is...Ch. 2 - (a) Transform v(t)=75cos(377t15) to phasor form....Ch. 2 - Let a 100V sinusoidal source be connected to a...Ch. 2 - Consider the circuit shown in Figure 2.23 in time...Ch. 2 - For the circuit shown in Figure 2.24, compute the...Ch. 2 - For the circuit element of Problem 2.3, calculate...Ch. 2 - Prob. 2.11PCh. 2 - The voltage v(t)=359.3cos(t)volts is applied to a...Ch. 2 - Prob. 2.13PCh. 2 - A single-phase source is applied to a...Ch. 2 - Let a voltage source v(t)=4cos(t+60) be connected...Ch. 2 - A single-phase, 120V(rms),60Hz source supplies...Ch. 2 - Consider a load impedance of Z=jwL connected to a...Ch. 2 - Let a series RLC network be connected to a source...Ch. 2 - Consider a single-phase load with an applied...Ch. 2 - A circuit consists of two impedances, Z1=2030 and...Ch. 2 - An industrial plant consisting primarily of...Ch. 2 - The real power delivered by a source to two...Ch. 2 - A single-phase source has a terminal voltage...Ch. 2 - A source supplies power to the following three...Ch. 2 - Consider the series RLC circuit of Problem 2.7 and...Ch. 2 - A small manufacturing plant is located 2 km down a...Ch. 2 - An industrial load consisting of a bank of...Ch. 2 - Three loads are connected in parallel across a...Ch. 2 - Prob. 2.29PCh. 2 - Figure 2.26 shows three loads connected in...Ch. 2 - Consider two interconnected voltage sources...Ch. 2 - Prob. 2.35PCh. 2 - Prob. 2.36PCh. 2 - Prob. 2.37PCh. 2 - Prob. 2.38PCh. 2 - Prob. 2.39PCh. 2 - A balanced three-phase 240-V source supplies a...Ch. 2 - Prob. 2.41PCh. 2 - A balanced -connected impedance load with (12+j9)...Ch. 2 - A three-phase line, which has an impedance of...Ch. 2 - Two balanced three-phase loads that are connected...Ch. 2 - Two balanced Y-connected loads, one drawing 10 kW...Ch. 2 - Three identical impedances Z=3030 are connected in...Ch. 2 - Two three-phase generators supply a three-phase...Ch. 2 - Prob. 2.48PCh. 2 - Figure 2.33 gives the general -Y transformation....Ch. 2 - Consider the balanced three-phase system shown in...Ch. 2 - A three-phase line with an impedance of...Ch. 2 - A balanced three-phase load is connected to a...Ch. 2 - What is a microgrid?Ch. 2 - What are the benefits of microgrids?Ch. 2 - Prob. CCSQCh. 2 - Prob. DCSQ
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License