Electrical Wiring: Residental - With Plans (Paperback) Package
18th Edition
ISBN: 9781305416376
Author: MULLIN
Publisher: Cengage
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 18, Problem 27R
To determine
Does the article NEC 210.8 (A)(5) contains any exemptions other than providing GFCI protection for the receptacles in the unfinished basement.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
1.1 PV modules can be wired together in an array using ______ connections to increase voltage.
a. Terminating
b. Series
c. Parallel
d. AC
1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit.
a. Capsules
b. Compartments
c. Chips
d. Cells
1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy.
a. Direct coupled
b. Self regulating
c. Charge controlled
d. Indirectly connected
1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage.
a. Coal
b. Natural Gas
c. Diesel
d. Solar
13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5
Chapter 18 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 18 - a. What circuit supplies the workshop lighting?...Ch. 18 - Prob. 2RCh. 18 - a. How is EMT fastened to masonry? _______________...Ch. 18 - What type of luminaires are installed on the...Ch. 18 - Prob. 5RCh. 18 - To what circuit are the smoke detectors connected?...Ch. 18 - Is it a Code requirement to connect smoke...Ch. 18 - Prob. 8RCh. 18 - Prob. 9RCh. 18 - Prob. 10R
Ch. 18 - Adjustment factors for conductor ampacities must...Ch. 18 - Prob. 12RCh. 18 - Prob. 13RCh. 18 - Calculate the total current draw of Circuit A17 if...Ch. 18 - Prob. 15RCh. 18 - A conduit body may contain splices if marked with...Ch. 18 - What size box would you use where Circuit A17...Ch. 18 - List the proper trade size of electrical metallic...Ch. 18 - According to the Code, what trade size EMT is...Ch. 18 - a. When more than three current-carrying...Ch. 18 - Prob. 21RCh. 18 - For laundry equipment in basements, what sort of...Ch. 18 - Prob. 23RCh. 18 - A Type NM cable carries a branch circuit to the...Ch. 18 - Prob. 25RCh. 18 - The following is a layout of the lighting circuits...Ch. 18 - Prob. 27RCh. 18 - Prob. 28R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forward1)The NEC Style Manual indicates that if a term in the NEC appears in more than two articles, it qualifies for a definition in which of the following. a) The articles where the term appears b) Article 90 c) Article 100 d) Table of Contents 2)Definitions of terms related to grounding and bonding and used only in Article 250 are located in ________.a) Article 100 b) Article 200 c) Chapter 9 d) Section 250.2 3)As a general rule, when installing ground rod electrodes, two must be installed always unless a single ground rod provides not more than 25 ohms’ resistance to ground. a) True b) Falsearrow_forwardAnswer the following: A) Type of clipper circuit per level of clipping. 1. ___________ 2. ___________ 3. ___________ B) Type of clipper circuit per non-linear devices used. 1. ___________ 2. ___________ C) Other term for clipper circuit. 1. ___________ 2. ___________ 3. ___________arrow_forward
- 13.a. What does Section 230.10 prohibit the use of for the support of overhead service conductors?A. Balcony railingsB. Trees and other types of vegetationC. Wooden fencingD. Lampposts 13.b. Section 230.6 establishes five conditions under which conductors can be physically located within abuilding or structure but can be considered _______ for the purposes of applying the Code requirements.A. protectedB. enabledC. chargedD. outsidearrow_forward21.Which of the following wiring methods may be used inside the duct used for vapor removal and ventilation of commercial type cooking equipment? (a.) nonmetallic sheathed cable (b.) EMT (c.) rigid steel conduit (d.) none of these 22. Ground-fault circuit-interrupter (GFCI) protection is required in all of the following locations EXCEPT: (a.) kitchen receptacles in an office building lunchroom installed within 6’ of the sink (b.) kitchen receptacles in a dwelling installed to serve counter top surfaces 10’ away from the sink (c.) receptacles in an office building restroom which has only a basin and toilet (d.) receptacle provided for servicing a rooftop air conditioning unit on the roof of a warehouse 23. Where GFCI protection is located in the power supply cord for an outdoor portable sign, the ground-fault circuit interrupter shall be located within _____inches of the attachment plug. (a.) 6 (c.) 18 (b.) 12 (d.) 24arrow_forward______________1. It is the ability of an electronic part to meet the required performance specifications in its life cycle application environment for a specified period. ______________2. It evaluates the performance and operating specifications of electronic components within the set standards. ______________3. It is the ability to detect and assess the errors in the system.arrow_forward
- All of the following can provide GFCI protection for kitchen countertop convenience receptacles EXCEPT:__________. Select one: a. AFCI/GFCI circuit-breakers b. by installing a single feed-through type GFCI receptacle to protect downstream receptacles c. AFCI circuit-breakers d. GFCI circuit-breakersarrow_forwardAfter reduction, the current - caring capacity of a condenser is referred to as the___. A. ambience b. Allowable ampacity c. ampacity d. ambient ratingarrow_forwardA means shall be provided in each metal box over 100 cubic inches for the connection of an equipment grounding conductor. The means shall be permitted to be ______. a tapped hole the cover screw III. a screw used to mount the box (a.) I only (c.) I & II only (b.) II only (d.) I, II or IIIarrow_forward
- If an electrical system operates at a potential higher than 600 volts, the nonmetallic conduit must be encased in at least_of concrete. A. 1 inch B. 2 inches C. 4 inches D. 6 inchesarrow_forwardWhich of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardQ34 Provide answers for the following: a) Differentiate between Planned preventive maintenance and condition based maintenance. b) List the condition monitoring tests used for: i. Circuit breakers ii. iv. Transformers Cables, and Busbars (need two examples for each category).arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT