Question
Chapter 18, Problem 18.8QAP
Interpretation Introduction
Interpretation:
The advantages and disadvantages of FT-Raman spectrometers in comparison to conventional dispersive Raman instruments are to be stated.
Concept introduction:
The Raman spectroscopy is based on the scattering of light. This is a spectroscopic technique. This technique usually used to determine the rotational vibrational and low frequency mode in the system.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A spectrophotometer has basic several components. Describe the role of each component and the justification for the setup of an instrument used for excitation spectroscopy and an instrument for emission spectroscopy.
What is the purpose of a matrix modifier in atomic spectroscopy?
Plasma emission spectroscopy can be used to determine the concentration of elements such as iron or zinc in pharmaceutical preparations. with the aid of suitable diagrams, outline the principles behind this technique and explain how it can be used to provide qualitative and quantitative information about these elements.
Knowledge Booster
Similar questions
- Compare the advantages and disadvantages of the inductively coupled plasma and flames in atomic spectroscopy.arrow_forwardHow would the position of a spectral line change as the separation d between the lines of the grating is increased?arrow_forwardExplain the origin of (a) absorption, (b) phosphorescence, and (c) Raman spectra. You may draw the Jablonski diagram to enhance your explanation.arrow_forward
- Suppose a student is preparing a set of standard solutions for use in a spectrophotometric study. If percent transmittance, %T, were measured in the standard solutions before the color had a chance to fully develop, the measured value would be compared with solutions that have allowed the color to fully develop.arrow_forward10. The Raman spectroscopy instrument records data and then plots signal intensity vs. raman shift. What are the actual wavelengths that are (1) emitted by the laser within the instrument that is directed at the sample and (2) that are sent back to the instrument due to a Raman interaction with your sample of dry ice that has a Raman active IR band at 1300 cm³¹.arrow_forwardUse the Analytical procedures in analytical chemistry to gain qualitative and quantitative information about palm oil adulterated with Sudan IV dye. Use the Raman spectroscopy as the analytical method.arrow_forward
- Calculate the ratio A/B for transitions with the following characteristics: (i) 500 MHz radiofrequency radiation, (ii) 3.0 cm microwave radiation.arrow_forwardThienothiophene and sexithiophene are conjugated molecules used in printed organic electronics. A chlorobenzene solution of equal concentrations of the two molecules was prepared and its absorbance was recorded with a 0.01 cm sample cell to give 0.88 % transmittance (T) at 400 nm. Calculate the concentration of each of the molecules given that the molar absorption coefficient of the thienothiophene is 23,000 L.mol-1cm-1 and the sexithiophene is 34,000 L.mol-1cm-1. Remember that absorbance is additive.arrow_forward4. When plotting a standard curve in absorption spectrophotometry, one uses Abs values instead of %T values. Explain why you need to use Abs values instead of %T values when constructing a standard curve (or a linear Beer's law Plot)arrow_forward
- Identify and provide either an concise explanation of the concept signal-to-noise ratio (SNR), in the context of chemical analysis.arrow_forward(i) Explain why Beer's Law breaks down when absorbance values are < 0.005. (ii) Explain the operation of a calcium source used in atomic absorbance spectroscopy. (iii) Explain why the calcium source described above will not operate for the quantification of magnesium.arrow_forward(i) Explain how the mass of the particle(s) involved affects the separation between energy levels in quantum mechanics. (ii) Explain why the sensitivity of an NMR experiment is affected by the strength of the applied magnetic field. (iii) Explain why, to a good approximation, rotational and vibrational transitions do not change the energies of electrons.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPhysical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,
- Principles of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning