Question
Chapter 17, Problem 17.9QAP
Interpretation Introduction
Interpretation:
The equation of the calibration curve should be determined and the concentration of the three unknown samples should be determined.
Concept introduction:
A calibration curve or standard curve is a method used in
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
كيمياء تحليليه
Flame Atomic Absorption Spectroscopy (FAAS) method is selected due to its wide applicability for metal ion analysis in drinking water samples.
Provide appropriate discussion to determine the concentration of selected heavy metals (Cu and Cr) in the unknown tap water sample.
A food supplement is analyzed by Atomic Absorption Spectroscopy to know its Ca content. A 10 ppm standard registers an absorbance of 0.448. A 4.45 g sample is calcined, the ashes are dissolved with 10 mL of acid, and the solution is finally made up to 50 mL; the absorbance reading was 0.325.
How many mg of Ca are in 100 g of the dietary supplement?
Chapter 17 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Similar questions
- A company is producing a powder which can be reconstituted as a healthy drink for the elderly. Analysis of the powder for calcium involved using the following procedure. 4 g of powder was reconstituted to 150 ml with water. Thirty ml of 24 % TCA was added to 30 ml of this solution. The mixture was allowed to stand for 15 mins and then filtered. The filtrate was analysed for calcium using atomic absorption spectroscopy. From the standard curve it was found that the reading for the analysed sample was 24mg/litre. Calculate the concentration of calcium in the powder (mg/kg).arrow_forwardWhat structural features of Hydroxypropyl Acrylate (HPA) allow it to be detected by HPLC?arrow_forwardA 5.3 × 10-2 M solution is to be used to prepare a series of five 100 mL solutions of varying concentration for use in creating a calibration curve for a spectrophotometric experiment. Determine the concentrations of each of the five dilutions if 10 mL aliquots of the current solution is used for V1.arrow_forward
- State True/False for the following statements. 1. In UV-Vis spectrophotometric analysis, the 2.82% transmittance of solution has an absorbance value of 1.55. 2. Peaks resulting transitions from n→ are shifted to shorter wavelengths (blue shift) with an increasing of solvent polarity. 3. In molecular absorption spectrophotometry, the relationship between transmittance and concentration is not linear while the absorbance vs concentration is linear. 4. Beer's Law states that absorbance of a compound is directly proportional to the log of the concentration of the absorbing species. 5. Different colors of the lights are refer to the waves with different amplitudes.arrow_forwardCalculate the amount of reagent needed to prepare 100 mL of a standard solution of 1000 ppm Au3+ in lN HCl for atomic absorption spectroscopy from standard HAuCl4.arrow_forwardPLEASE ANSWER ASAParrow_forward
- The molar absorptivity constant of a particular chemical is 3.9 dm3 mol–1 cm–1 . What is the concentration (in Molar) of a solution made from this chemical that has an absorbance of 0.410 with a cell path length of 1.0cm?arrow_forwardYou are measuring the concentration of an unknown protein sample, and the absorbance at 595 nm (or A595) of your unknown is greater than that of the highest-concentration standard solution. It is not advisable to simply extrapolate the line of the standard curve to calculate the concentration of the unknown In this scenario, what would be the best strategy to measure the concentration of your unknown (instead of extrapolating from the standard curve)?arrow_forwardWhat is the molar extinction coefficient at 625 nm for this copper (II) acetate solution? How was it determined? Can the calibration curve be used to accurately predict the absorbance of 0.0150 M copper (II) acetate solution at 625? Why or why not?arrow_forward
- Given the following data find the Molar absorption coefficient for Fe(SCN)^2+}Fe(SCN)X2+, (M−1 cm−1), if the length is 2.24cm. FIND THE UNROUNDED VALUE. Unrounded Rounded Molar absorption coefficient for \ce{Fe(SCN)^2+}Fe(SCN)X2+, (M−1 cm−1) Sample FROM PRELAB EXPERIMENTAL DATA CALCULATED VALUES 0.000300 M Absorbance Fe(SCN)X2+]equ, (M) --> for next bar 1 1.50 0.210166 0.0000300 2 3.50 0.466178 0.0000700 3 7.00 0.912604 0.000140 4 10.00 1.348948 0.000200 SLOPE, (M−1) INTERCEPT R^2R2 Unrounded 6.66606 × 103 1.20727 × 10-3 0.998979arrow_forward7) A 25.0 ml sample containing Cu gave an instrument reading of 23.6 units (corrected for a blank). When exactly 0.500 ml of 0.0287M Cu(NO3)2 Was added to the solution,the signal increased to 37.9 units. Calculate the molar concentration of Cu" in the sample +2,arrow_forwardThe following data are obtained from three standard soltions using UV-Vis spectroscopy: What is the colar concentration (M) of an unknown solution with an absorbance of 0.180 at 255 nm? The unknown solution contains the same analyte as the standard solution does. The molar mass of the analyte is 188.65 g/mol a) 4.82x10-5b)1.9x10-3c)3.60x10-4d)1.9x10-5e)1.8x 10-4arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning