Textbook Question
Chapter 15, Problem 19RQ
Explain why a service technician must always know where line 1 and line 2 are in relation to one another when voltage troubleshooting a schematic wiring diagram.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Case #1: A 10 -story office building has an electrical system with an automatic switch
of 200 amps on the main panel. On the 6th floor, an employee brings a high coffee machine
Power that makes the diliters constantly shoot. The building manager
worries about the impact that this could have in other tenants of the building and decides that
You need a solution. What is the best solution to solve this problem?
All terminals have a defined wire size range. If I had a wire of 2.0mm / 15 AWG, what terminal should I use?
A. Red insulated terminal.
B. Blue insulated terminal.
C. Yellow insulated terminal.
D. It doesn’t matter as all these answers are correct.
Name
Section 5-2: Line Diagrams-Signals,
Decisions, and Actions
In the following application, a temperature switch controls a heating contactor and a flow switch is used to
ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required
information.
1. List all the signal devices in the circuit.
2. List all the action devices in the circuit.
3. List the decision part of the circuit that automatically sounds the alarm if there is a problem.
4. When the heating element is on during normal operation, is the flow switch open or closed?
CIRCULATING
2
L1
FAN
TEMPERATURE
SWITCH
TR
HEATING
ELEMENTS
FLOW
SWITCH
-HOT AIR
PADDLE
AIR FILTER
NORMALLY CLOSED
FLOW SWITCH
65
ALARM
(SOUNDS IF NO FLOW FOR
15 SECONDS OR MORE)
Date
HEATING
CONTACTOR
TR
ON-DELAY
TIMER
SUPPLY AIR
COLD AIR
(3) TIME SET= 15 SEC
© 2014 American Technical Publishers, Inc.
All rights reserved
Chapter 15 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
Ch. 15 - Name three types of automatic controls.Ch. 15 - Two categories ofelectric controls...Ch. 15 - What circuit is energized with the thermostat Y...Ch. 15 - The component in the system that is energized when...Ch. 15 - The ________terminal must be energized in the...Ch. 15 - The hot circuit in the thermostat is the...Ch. 15 - Is the heat anticipator in series or parallel with...Ch. 15 - The cooling anticipator is wired A. in parallel...Ch. 15 - Which anticipator is adjustable, heat or cool?Ch. 15 - True or False: The indoor fan must always run...
Ch. 15 - True or False: When the control transformer is not...Ch. 15 - Which of the following should be turned off while...Ch. 15 - The _______diagram is used to locate different...Ch. 15 - To trace the circuits in the unit, the...Ch. 15 - Prob. 15RQCh. 15 - Prob. 16RQCh. 15 - Prob. 17RQCh. 15 - True or False: Open switches will always read...Ch. 15 - Explain why a service technician must always know...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which of the following information is not given in a wiring diagram? Wire-by-wire color coding Location of wire harness travel Terminal designation Component designationsarrow_forwardWhat two types of switches are normally found in the subbase of a low-voltage thermostat?arrow_forwardWhat causes an overload protection device to function?arrow_forward
- Refer to the circuit shown in Figure 5-29. Is the thermostat contact normally open, normally closed, normally closed held open, or normally open held closed? Figure 5-29 The contactor contains both load and auxiliary contacts.arrow_forwardA pressure switch is to be installed in a circuit that requires it to have three normally open contacts and one normally closed contact. The switch actually has one normally open Contact What must be done to permit this pressure switch to operate in this circuit?arrow_forwardWhy is a low-voltage thermostat normally more accurate than a high-voltage thermostat?arrow_forward
- Three common controls used in central electric heat applications are thermostats, contactors (or relays), and A. capacitors. B. sequencers. C. cool anticipators.arrow_forwardVoltage can be described as ____________ .arrow_forwardTo answer the following questions refer to the circuit in Figure 416. The pressure switch is shown as: a. Normally open b. Normally closed c. Normally open held closed d. Normally closed held openarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningAutomotive TechnologyMechanical EngineeringISBN:9781337794213Author:ERJAVEC, Jack.Publisher:Cengage,Welding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Automotive Technology
Mechanical Engineering
ISBN:9781337794213
Author:ERJAVEC, Jack.
Publisher:Cengage,
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
General Industrial Safety; Author: Jim Pytel;https://www.youtube.com/watch?v=RXtF_vQRebM;License: Standard youtube license