EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 15, Problem 18R
A residential air-conditioning unit is installed in the attic.
- a. Is a lighting outlet required? __________
- b. What Code section applies? __________
- c. If a lighting outlet is required, how shall it be controlled? __________
- d. What Code section applies? __________
- e. Is a receptacle outlet required? __________
- f. What Code section applies? __________
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
45. A switch or circuit breaker can be used as both the controller and disconnecting means if
it
a. opens all ungrounded conductors as required by NEC 430.103
b. is protected by an overcurrent device in each ungrounded conductor
c. is manually operable, or both power and manually operable
d. All of these answers
2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.
1.1 PV modules can be wired together in an array using ______ connections to increase voltage.
a. Terminating
b. Series
c. Parallel
d. AC
1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit.
a. Capsules
b. Compartments
c. Chips
d. Cells
1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy.
a. Direct coupled
b. Self regulating
c. Charge controlled
d. Indirectly connected
1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage.
a. Coal
b. Natural Gas
c. Diesel
d. Solar
Chapter 15 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 15 - Prob. 1RCh. 15 - Prob. 2RCh. 15 - What special type of switch is controlling the...Ch. 15 - Prob. 4RCh. 15 - The total estimated volt-amperes for Circuit B10...Ch. 15 - If an attic is accessible through a scuttle hole,...Ch. 15 - Prob. 7RCh. 15 - Prob. 8RCh. 15 - The following is a layout of the lighting circuit...Ch. 15 - Prob. 10R
Ch. 15 - Prob. 11RCh. 15 - a. What is the minimum power demand allowed by the...Ch. 15 - What is the maximum permitted current rating of a...Ch. 15 - Prob. 14RCh. 15 - a. Must the metal frame of an electric clothes...Ch. 15 - An electric dryer is rated at 7.5 kW and 120/240...Ch. 15 - When a metal junction box is installed as part of...Ch. 15 - A residential air-conditioning unit is installed...Ch. 15 - The Code states that a means must be provided to...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
A byte is made up of eight a. CPUs b. addresses c. variables d. bits
Starting Out with Java: From Control Structures through Objects (7th Edition) (What's New in Computer Science)
1.2 Explain the difference between geodetic and plane
surveys,
Elementary Surveying: An Introduction To Geomatics (15th Edition)
Consider the adage Never ask a question for which you do not want the answer. a. Is following that adage ethica...
Experiencing MIS
The job of the _____ is to fetch instructions, carry out the operations commanded by the instructions, and prod...
Starting Out With Visual Basic (8th Edition)
What is the importance of modeling in engineering? How are the mathematical models for engineering processes pr...
HEAT+MASS TRANSFER:FUND.+APPL.
How is the hydrodynamic entry length defined for flow in a pipe? Is the entry length longer in laminar or turbu...
Fluid Mechanics: Fundamentals and Applications
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 6. According to the NEC, allowance for the future expansion of installations isA. an exception.B. in everyone's best interest.C. defined.D. a requirement.arrow_forwardTwo of the circuits will be a 3-wire, multi-wire branch circuit (Edison 3-wire). The location of the devices is to be determined by the student. The student shall be responsible for selecting the correct circuits, do not ask the instructor which circuit number should be used. Circuit A. One lampholder and one duplex receptacle controlled by a Single Pole Switch. Circuit B. Single Pole Switch controlling the top half of a duplex receptacle that when energized, is indicated by a Pilot-light at the Single Pole Switch location; plus an Isolated Ground Duplex Receptacle that is always hot. Circuit C. The bottom half of the switched receptacle on Circuit ‘B’ is to be always hot; plus another Duplex Receptacle that is controlled from two locations using a Coast 3-Way wiring-system.arrow_forwardA device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forward
- Multiple choicesarrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forward2. When working on a high - voltage system , it is best to keep anyone who is not part of the ser vice away from you and the car by creating a buffer zone around the car . Technician A makes sure the outside edges of the zone are at least one foot away from the car . Technician B places B orange cones to define the outer boundaries of the zone. Who is correct ?arrow_forwardmultiple choicesarrow_forward
- 12. Which of the following statements about ground faults is true?A. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.B. They usually occur between any grounded circuit conductor and the equipment grounding conductor.C. They can't result from human error.D. They're often normal and typically intentional.arrow_forward4.a. The ___ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total 4.b. What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight 4.c. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.arrow_forward(b) An employee is working on a ladder and the ladder seems to collapse. The employee falls off the ladder and breaks arm. The investigation reveals the following details: • Employee had worked seven 12-hour shifts in a row. • Accident happened at end of shift. • Employee was standing on the top step of the ladder (an unsafe action). The employee was approximately 10 feet above floor level. No fall arrest or restraint system was used. • A ladder inspection policy is in place, but there is no evidence that the ladder has ever been inspected. Investigation reveals the ladder was damaged and did not provide a stable working platform in any environment. • Interview with the facility manager reveals that he did not inspect the ladder when it was due for inspection. He was aware that the ladder needed to be inspected. (i) Examine either accident investigation is required or not. (ii) Discover SIX (6) factors and possible causes affecting the incidences. (iii) Explain the root cause of the…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License