THERMODYNAMICS-SI ED. EBOOK >I<
9th Edition
ISBN: 9781307573022
Author: CENGEL
Publisher: MCG/CREATE
expand_more
expand_more
format_list_bulleted
Question
Chapter 14.7, Problem 85P
(a)
To determine
Sketch the system hardware and the psychrometric diagram for the process.
(b)
To determine
The inlet volume flow rate of atmospheric air for the process.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
In an air-conditioning unit 3.5 m3/s of air at 28 C dry-bulb temperature, 50 percent relative humidity, and standard atmospheric pressure enters the unit. The leaving condition of the air is 14 C dry-bulb temperature and 90 percent relative humdity. Using properties from the psychrometric chart, (a) calculate the refrigeratingcapacity in kilowatts and (b) determine the rate of water removal from the air
1. In the process of air conditioning in a humidifier, the air at a dry bulb temperature of 20 °C and 25% RH increases its RH to 40%. Determine the amount of moisture added in the humidifier per kg of dry air. = (kg water/kg air).
2. The air has a dry bulb temperature of 34 °C and a wet bulb temperature of 22°C. The liquid is heated in a heater so that the dry bulb temperature increases to 80 °C. Then the air is passed through the corn kernels to dry. The air coming out of the corn kernels is at bulb temperature. dry 55 °C Then this air is passed to the dehumidifier to reduce its RH to 10%. Draw the course of the air change process on a psychrometric diagram. The rate of air flow through the corn kernels and dehumidifier is 4.0 m/s and the cross-sectional diameter of the pile is 0.7 m.
a) Determine the amount of water content lost from the pile of corn kernels (in grams of water/second)
b) Determine the amount of water content lost from the air when passing through the…
Air at a condition of 30˚C dry bulb, 17˚C wet bulb, and a barometric pressure of 1.05 bar enter equipment where it undergoes a process of adiabatic saturation, the air leaving with a moisture content of 5g/kg higher than while it was while entering. At constant specific volume process Using the thermodynamic properties of air determine: (Do not use the psychrometric chart)
the moisture content leaving the equipment, kg vapor/kg air
Chapter 14 Solutions
THERMODYNAMICS-SI ED. EBOOK >I<
Ch. 14.7 - What is the difference between dry air and...Ch. 14.7 - What is vapor pressure?Ch. 14.7 - What is the difference between the specific...Ch. 14.7 - Can the water vapor in air be treated as an ideal...Ch. 14.7 - Explain how vapor pressure of the ambient air is...Ch. 14.7 - Is the relative humidity of saturated air...Ch. 14.7 - Moist air is passed through a cooling section...Ch. 14.7 - How will (a) the specific humidity and (b) the...Ch. 14.7 - Prob. 9PCh. 14.7 - Consider a tank that contains moist air at 3 atm...
Ch. 14.7 - Is it possible to obtain saturated air from...Ch. 14.7 - Why are the chilled water lines always wrapped...Ch. 14.7 - How would you compare the enthalpy of water vapor...Ch. 14.7 - A tank contains 15 kg of dry air and 0.17 kg of...Ch. 14.7 - Prob. 15PCh. 14.7 - An 8-m3 tank contains saturated air at 30C, 105...Ch. 14.7 - Determine the masses of dry air and the water...Ch. 14.7 - A room contains air at 85F and 13.5 psia at a...Ch. 14.7 - Prob. 19PCh. 14.7 - Prob. 20PCh. 14.7 - Prob. 21PCh. 14.7 - In summer, the outer surface of a glass filled...Ch. 14.7 - In some climates, cleaning the ice off the...Ch. 14.7 - Andy and Wendy both wear glasses. On a cold winter...Ch. 14.7 - Prob. 25PCh. 14.7 - Prob. 26PCh. 14.7 - Prob. 27PCh. 14.7 - A thirsty woman opens the refrigerator and picks...Ch. 14.7 - The air in a room has a dry-bulb temperature of...Ch. 14.7 - Prob. 31PCh. 14.7 - Prob. 32PCh. 14.7 - Prob. 33PCh. 14.7 - How do constant-enthalpy and...Ch. 14.7 - At what states on the psychrometric chart are the...Ch. 14.7 - How is the dew-point temperature at a specified...Ch. 14.7 - Can the enthalpy values determined from a...Ch. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Prob. 39PCh. 14.7 - Prob. 40PCh. 14.7 - Prob. 41PCh. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Reconsider Prob. 1443. Determine the adiabatic...Ch. 14.7 - What does a modern air-conditioning system do...Ch. 14.7 - How does the human body respond to (a) hot...Ch. 14.7 - How does the air motion in the vicinity of the...Ch. 14.7 - Consider a tennis match in cold weather where both...Ch. 14.7 - Prob. 49PCh. 14.7 - Prob. 50PCh. 14.7 - Prob. 51PCh. 14.7 - Prob. 52PCh. 14.7 - What is metabolism? What is the range of metabolic...Ch. 14.7 - Why is the metabolic rate of women, in general,...Ch. 14.7 - What is sensible heat? How is the sensible heat...Ch. 14.7 - Prob. 56PCh. 14.7 - Prob. 57PCh. 14.7 - Prob. 58PCh. 14.7 - Prob. 59PCh. 14.7 - Repeat Prob. 1459 for an infiltration rate of 1.8...Ch. 14.7 - An average (1.82 kg or 4.0 lbm) chicken has a...Ch. 14.7 - An average person produces 0.25 kg of moisture...Ch. 14.7 - How do relative and specific humidities change...Ch. 14.7 - Prob. 64PCh. 14.7 - Humid air at 150 kPa, 40C, and 70 percent relative...Ch. 14.7 - Humid air at 40 psia, 50F, and 90 percent relative...Ch. 14.7 - Prob. 67PCh. 14.7 - Air enters a 30-cm-diameter cooling section at 1...Ch. 14.7 - Prob. 69PCh. 14.7 - Prob. 70PCh. 14.7 - Why is heated air sometimes humidified?Ch. 14.7 - Air at 1 atm, 15C, and 60 percent relative...Ch. 14.7 - Air at 14.7 psia, 35F, and 50 percent relative...Ch. 14.7 - An air-conditioning system operates at a total...Ch. 14.7 - Prob. 75PCh. 14.7 - Why is cooled air sometimes reheated in summer...Ch. 14.7 - Atmospheric air at 1 atm, 30C, and 80 percent...Ch. 14.7 - Ten thousand cubic feet per hour of atmospheric...Ch. 14.7 - Air enters a 40-cm-diameter cooling section at 1...Ch. 14.7 - Repeat Prob. 1479 for a total pressure of 88 kPa...Ch. 14.7 - On a summer day in New Orleans, Louisiana, the...Ch. 14.7 - Prob. 83PCh. 14.7 - Prob. 84PCh. 14.7 - Prob. 85PCh. 14.7 - Saturated humid air at 70 psia and 200F is cooled...Ch. 14.7 - Humid air is to be conditioned in a...Ch. 14.7 - Atmospheric air at 1 atm, 32C, and 95 percent...Ch. 14.7 - Prob. 89PCh. 14.7 - Prob. 90PCh. 14.7 - Does an evaporation process have to involve heat...Ch. 14.7 - Prob. 92PCh. 14.7 - Prob. 93PCh. 14.7 - Air enters an evaporative (or swamp) cooler at...Ch. 14.7 - Prob. 95PCh. 14.7 - Air at 1 atm, 20C, and 70 percent relative...Ch. 14.7 - Two unsaturated airstreams are mixed...Ch. 14.7 - Consider the adiabatic mixing of two airstreams....Ch. 14.7 - Two airstreams are mixed steadily and...Ch. 14.7 - A stream of warm air with a dry-bulb temperature...Ch. 14.7 - Prob. 104PCh. 14.7 - Prob. 105PCh. 14.7 - How does a natural-draft wet cooling tower work?Ch. 14.7 - What is a spray pond? How does its performance...Ch. 14.7 - The cooling water from the condenser of a power...Ch. 14.7 - A wet cooling tower is to cool 60 kg/s of water...Ch. 14.7 - Prob. 110PCh. 14.7 - Prob. 111PCh. 14.7 - Water at 30C is to be cooled to 22C in a cooling...Ch. 14.7 - Prob. 113PCh. 14.7 - Prob. 114RPCh. 14.7 - Determine the mole fraction of dry air at the...Ch. 14.7 - Prob. 116RPCh. 14.7 - Prob. 117RPCh. 14.7 - Prob. 118RPCh. 14.7 - Prob. 119RPCh. 14.7 - Prob. 120RPCh. 14.7 - Prob. 121RPCh. 14.7 - Prob. 122RPCh. 14.7 - Prob. 124RPCh. 14.7 - Prob. 125RPCh. 14.7 - Prob. 126RPCh. 14.7 - Prob. 128RPCh. 14.7 - Prob. 129RPCh. 14.7 - Air enters a cooling section at 97 kPa, 35C, and...Ch. 14.7 - Prob. 131RPCh. 14.7 - Atmospheric air enters an air-conditioning system...Ch. 14.7 - Humid air at 101.3 kPa, 36C dry bulb and 65...Ch. 14.7 - An automobile air conditioner uses...Ch. 14.7 - Prob. 135RPCh. 14.7 - Prob. 137RPCh. 14.7 - Conditioned air at 13C and 90 percent relative...Ch. 14.7 - Prob. 141FEPCh. 14.7 - A 40-m3 room contains air at 30C and a total...Ch. 14.7 - A room is filled with saturated moist air at 25C...Ch. 14.7 - Prob. 144FEPCh. 14.7 - The air in a house is at 25C and 65 percent...Ch. 14.7 - Prob. 146FEPCh. 14.7 - Air at a total pressure of 90 kPa, 15C, and 75...Ch. 14.7 - On the psychrometric chart, a cooling and...Ch. 14.7 - On the psychrometric chart, a heating and...Ch. 14.7 - An airstream at a specified temperature and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In an air-conditioning unit 3.5 m3/s air at 27°C dry-bulb temperature, 21°C wet-bulb temperature, and 90 kPa atmospheric pressure enters the unit. The leaving condition of the air is 13°C dry-bulb temperature and 90 percent relative humidity. Calculate the inlet air mass flow rate in kg/s.arrow_forwardPlease assist with this Thermodynamics question. It's urgent.Thanks in advancearrow_forwardCan you make a schematic diagram for this problem? 600 lps of air at 30°C dry-bulb and 22°C wet-bulb temperatures is heated to a temperature of 45°C and enters the dryer. The air leaves the dryer adiabatically and its relative humidity is 70%. Determine: (a.) The water evaporated kg/hr; (b.) The volume air leaving the dryer in cu.m/min; and (c.) kJ requirement of the dryer per kg of water evaporated.arrow_forward
- 1.5 m3/s of moist air at a state of 28°C DB, 21°C WB, and 101.325 kPa flows across a cooler coil and leaves at 12.5°C DB and 0.0083 kg/kg d.a. Determine the following: A) The Apparatus Dew-Point Temperature in °C using the Psychrometric Chart. B) The By-Pass Factor in Percentile (%). C) The Cooling Load of the process in kilowatts.arrow_forwardMoist air at 32 degrees Cdb and relative humidity of 60% enter a refrigeration system with a flow rate of 90 kg/min. Saturated air at 15 degrees Cdb leaves the system. Calculate the heat and moisture removed in kW and kg/s respectively.arrow_forwardAn auditorium seating 1800 people in three consecutive sitting for 6 hours, is to be maintained at 25°C dry bulb and 20°C wet bulb temperatures with outdoor air at 35°C dry bulb and 60% relative humidity. Conditioned air enters the auditorium at 15°C. Ventilation requirement is 8 m³/hr per person. Solar and other heat loads amount to 108,000 KJ/hr. The sensible and latent heat loads from the occupants is 275 KJ/hr per person and 150 KJ/hr per person, respectively. The ventilation load is nearest to what value? 266.64 kw 29.63 kw 115 kw 44.12 kwarrow_forward
- Q.1 An air conditioning system supplying air to a space with a sensible heat load of 14 kW and a latent heat load of 9 kW has a cooling coil and a bypass path as shown schematically in Fig. The db- temperature of the space is maintained at 26°C. The dry air mass flow rate of supply air is 1.2kg/s. Outdoor ventilation air at 34°C db-temperature and 50% relative humidity is introduced into the system with a dry air mass flow rate of 0.26 kg/s. The air leaving the cooling coil is fully saturated at a db-temperature of 6°C. The pressure is constant at 101.3 kPa. Determine db-temperature and relative humidity of the supply air to the space, (ii) (i) (ii) (iv) wb-temperature of the space, temperature of the air entering the cooling coil, and refrigeration capacity of the cooling coil.arrow_forwardAtmospheric air at 1 atm, 32°C, and 95 percent relative humidity is cooled to 24°C and 60 percent relative humidity at a rate of 20 m³/min as shown in Figure Q2. A simple ideal vapor-compression refrigeration system using refrigerant-134a as the working fluid with 0.05kg/s mass flow rate, is used to provide the cooling required. It operates its evaporator at 4°C and its condenser at a saturation temperature of 39.4°C. The condenser rejects its heat to the atmospheric air. Calculate: a. the amount of water, in kg/kg dry air, removed from the air, b. the rate of heat removed from the air, in kJ/kg dry air, c. the rate of heat rejected at the condenser, d. sketch the process on the psychrometric chart provided. Expansion valve 24°C 60% Evaporator -www- Dry air mass balance: Water mass balance: Energy balance: Condenser in ₁ h= 0 Condensate Compressor m = m = m I alm Figure Q2 + Σinh m₂ + m₂ →Q 1 32°C 95% m₂ = m (, -a) = m(h, -h₂)-mharrow_forwardi was trying to understand and studying thermodynamics course but this example had seen pretty hard to me. thanks to the person who can explain the solution of that example to me.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY