THERMODYNAMICS LLF W/ CONNECT ACCESS
9th Edition
ISBN: 9781264446889
Author: CENGEL
Publisher: MCG
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 14.7, Problem 77P
Atmospheric air at 1 atm, 30°C, and 80 percent relative humidity is cooled to 20°C while the mixture pressure remains constant. Calculate the amount of water, in kg/kg dry air, removed from the air and the cooling requirement, in kJ/kg dry air, when the liquid water leaves the system at 22°C.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Moist air initially at 120 °C, 3 bar, and 60% relative humidity is contained in a 4-m³ closed, rigid
tank. The tank contents are cooled. Determine the heat transfer, in kJ, if the final temperature in
the tank is 50 °C.
(Note: The gas constant of water vapor is R = 0.4614 kJ/kg K: gas constant of air is R = 0.287
kJ/kg K)
Moist air at 105 kPa, 30° C and 80% relative humidity
flows over a cooling coil in an insulated air-conditioning
duct. Saturated air exists the duct at 100kPa and 15°C.
The saturation pressure of water at 30° C and 15°C are
4.24 kPa and 1.7 kPa, respectively. Molecular weight of
water is 18 g/mol and that of air is 28.94 g/mol. The
mass of water condensing out from the duct is ...
g/kg of dry air (round off to 2 decimal places).
Air enters a heating section at 95 kPa, 10°C, and 30 percent relative humidity at a rate of 6.2 m3/min, and it leaves at 25 C Use data from the tables.
Determine the rate of heat transfer in the heating section
The rate of heat transfer is [
kJ/min
Chapter 14 Solutions
THERMODYNAMICS LLF W/ CONNECT ACCESS
Ch. 14.7 - What is the difference between dry air and...Ch. 14.7 - What is vapor pressure?Ch. 14.7 - What is the difference between the specific...Ch. 14.7 - Can the water vapor in air be treated as an ideal...Ch. 14.7 - Explain how vapor pressure of the ambient air is...Ch. 14.7 - Is the relative humidity of saturated air...Ch. 14.7 - Moist air is passed through a cooling section...Ch. 14.7 - How will (a) the specific humidity and (b) the...Ch. 14.7 - Prob. 9PCh. 14.7 - Consider a tank that contains moist air at 3 atm...
Ch. 14.7 - Is it possible to obtain saturated air from...Ch. 14.7 - Why are the chilled water lines always wrapped...Ch. 14.7 - How would you compare the enthalpy of water vapor...Ch. 14.7 - A tank contains 15 kg of dry air and 0.17 kg of...Ch. 14.7 - Prob. 15PCh. 14.7 - An 8-m3 tank contains saturated air at 30C, 105...Ch. 14.7 - Determine the masses of dry air and the water...Ch. 14.7 - A room contains air at 85F and 13.5 psia at a...Ch. 14.7 - Prob. 19PCh. 14.7 - Prob. 20PCh. 14.7 - Prob. 21PCh. 14.7 - In summer, the outer surface of a glass filled...Ch. 14.7 - In some climates, cleaning the ice off the...Ch. 14.7 - Andy and Wendy both wear glasses. On a cold winter...Ch. 14.7 - Prob. 25PCh. 14.7 - Prob. 26PCh. 14.7 - Prob. 27PCh. 14.7 - A thirsty woman opens the refrigerator and picks...Ch. 14.7 - The air in a room has a dry-bulb temperature of...Ch. 14.7 - Prob. 31PCh. 14.7 - Prob. 32PCh. 14.7 - Prob. 33PCh. 14.7 - How do constant-enthalpy and...Ch. 14.7 - At what states on the psychrometric chart are the...Ch. 14.7 - How is the dew-point temperature at a specified...Ch. 14.7 - Can the enthalpy values determined from a...Ch. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Prob. 39PCh. 14.7 - Prob. 40PCh. 14.7 - Prob. 41PCh. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Reconsider Prob. 1443. Determine the adiabatic...Ch. 14.7 - What does a modern air-conditioning system do...Ch. 14.7 - How does the human body respond to (a) hot...Ch. 14.7 - How does the air motion in the vicinity of the...Ch. 14.7 - Consider a tennis match in cold weather where both...Ch. 14.7 - Prob. 49PCh. 14.7 - Prob. 50PCh. 14.7 - Prob. 51PCh. 14.7 - Prob. 52PCh. 14.7 - What is metabolism? What is the range of metabolic...Ch. 14.7 - Why is the metabolic rate of women, in general,...Ch. 14.7 - What is sensible heat? How is the sensible heat...Ch. 14.7 - Prob. 56PCh. 14.7 - Prob. 57PCh. 14.7 - Prob. 58PCh. 14.7 - Prob. 59PCh. 14.7 - Repeat Prob. 1459 for an infiltration rate of 1.8...Ch. 14.7 - An average (1.82 kg or 4.0 lbm) chicken has a...Ch. 14.7 - An average person produces 0.25 kg of moisture...Ch. 14.7 - How do relative and specific humidities change...Ch. 14.7 - Prob. 64PCh. 14.7 - Humid air at 150 kPa, 40C, and 70 percent relative...Ch. 14.7 - Humid air at 40 psia, 50F, and 90 percent relative...Ch. 14.7 - Prob. 67PCh. 14.7 - Air enters a 30-cm-diameter cooling section at 1...Ch. 14.7 - Prob. 69PCh. 14.7 - Prob. 70PCh. 14.7 - Why is heated air sometimes humidified?Ch. 14.7 - Air at 1 atm, 15C, and 60 percent relative...Ch. 14.7 - Air at 14.7 psia, 35F, and 50 percent relative...Ch. 14.7 - An air-conditioning system operates at a total...Ch. 14.7 - Prob. 75PCh. 14.7 - Why is cooled air sometimes reheated in summer...Ch. 14.7 - Atmospheric air at 1 atm, 30C, and 80 percent...Ch. 14.7 - Ten thousand cubic feet per hour of atmospheric...Ch. 14.7 - Air enters a 40-cm-diameter cooling section at 1...Ch. 14.7 - Repeat Prob. 1479 for a total pressure of 88 kPa...Ch. 14.7 - On a summer day in New Orleans, Louisiana, the...Ch. 14.7 - Prob. 83PCh. 14.7 - Prob. 84PCh. 14.7 - Prob. 85PCh. 14.7 - Saturated humid air at 70 psia and 200F is cooled...Ch. 14.7 - Humid air is to be conditioned in a...Ch. 14.7 - Atmospheric air at 1 atm, 32C, and 95 percent...Ch. 14.7 - Prob. 89PCh. 14.7 - Prob. 90PCh. 14.7 - Does an evaporation process have to involve heat...Ch. 14.7 - Prob. 92PCh. 14.7 - Prob. 93PCh. 14.7 - Air enters an evaporative (or swamp) cooler at...Ch. 14.7 - Prob. 95PCh. 14.7 - Air at 1 atm, 20C, and 70 percent relative...Ch. 14.7 - Two unsaturated airstreams are mixed...Ch. 14.7 - Consider the adiabatic mixing of two airstreams....Ch. 14.7 - Two airstreams are mixed steadily and...Ch. 14.7 - A stream of warm air with a dry-bulb temperature...Ch. 14.7 - Prob. 104PCh. 14.7 - Prob. 105PCh. 14.7 - How does a natural-draft wet cooling tower work?Ch. 14.7 - What is a spray pond? How does its performance...Ch. 14.7 - The cooling water from the condenser of a power...Ch. 14.7 - A wet cooling tower is to cool 60 kg/s of water...Ch. 14.7 - Prob. 110PCh. 14.7 - Prob. 111PCh. 14.7 - Water at 30C is to be cooled to 22C in a cooling...Ch. 14.7 - Prob. 113PCh. 14.7 - Prob. 114RPCh. 14.7 - Determine the mole fraction of dry air at the...Ch. 14.7 - Prob. 116RPCh. 14.7 - Prob. 117RPCh. 14.7 - Prob. 118RPCh. 14.7 - Prob. 119RPCh. 14.7 - Prob. 120RPCh. 14.7 - Prob. 121RPCh. 14.7 - Prob. 122RPCh. 14.7 - Prob. 124RPCh. 14.7 - Prob. 125RPCh. 14.7 - Prob. 126RPCh. 14.7 - Prob. 128RPCh. 14.7 - Prob. 129RPCh. 14.7 - Air enters a cooling section at 97 kPa, 35C, and...Ch. 14.7 - Prob. 131RPCh. 14.7 - Atmospheric air enters an air-conditioning system...Ch. 14.7 - Humid air at 101.3 kPa, 36C dry bulb and 65...Ch. 14.7 - An automobile air conditioner uses...Ch. 14.7 - Prob. 135RPCh. 14.7 - Prob. 137RPCh. 14.7 - Conditioned air at 13C and 90 percent relative...Ch. 14.7 - Prob. 141FEPCh. 14.7 - A 40-m3 room contains air at 30C and a total...Ch. 14.7 - A room is filled with saturated moist air at 25C...Ch. 14.7 - Prob. 144FEPCh. 14.7 - The air in a house is at 25C and 65 percent...Ch. 14.7 - Prob. 146FEPCh. 14.7 - Air at a total pressure of 90 kPa, 15C, and 75...Ch. 14.7 - On the psychrometric chart, a cooling and...Ch. 14.7 - On the psychrometric chart, a heating and...Ch. 14.7 - An airstream at a specified temperature and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Handwritten solution -Thermoarrow_forwardAmbient air is at a pressure of 100kPa, dry bulb temperature of 30°C and 60% relative humidity. The saturation pressure of water at 300 C is 4.24 kPa. Calcuate the specific humidity of air (in g/kg of dry air) .arrow_forwardTwo airstreams are mixed steadily and adiabatically. The first stream enters at 35°C and 30 percent relative humidity at a rate of 15 m/min, while the second stream enters at 12°C and 90 percent relative humidity at a rate of 23.5 m/min. Assuming that the mixing process occurs at a pressure of 90 kPa, determine the specific humidity, the relative humidity, the dry-bulb temperature, and the volume flow rate of the mixture. Use data from the tables. 35°C 30% P-90 kPa Air 12°C 90% The specific humidity is kg H20/kg dry air. The relative humidity is %. The dry-bulb temperature is 1°C. m3/min. The volume flow rate of the mixture isarrow_forward
- Outdoor air at 35°C dry-bulb and 19°C dewpoint temperatures are to be mixed with room air at 26°C dry-bulb temperature and specific humidity of 0.0105 kgv/kga. The mass of outdoor air is one-third of the mass of the mixture. Find the following properties of the mixed air: Dry-bulb temperature Specific humidity Enthalpy Relative humidity Dewpoint temperature Specific volumearrow_forwardThis question is important,give the right answer.arrow_forwardTwo airstreams are mixed steadily and adiabatically. The first stream enters at 35OC and 30 percent relative humidity at a rate of 15 m3 /min, while the second stream enters at 12OC and 90 percent relative humidity at a rate of 25 m3 /min. Assuming that the mixing process occurs at a pressure of 1 atm, determine the The specific humidity, Answer The relative humidity, Answer The dry-bulb temperature Answer The volume flow rate of the mixture Answerarrow_forward
- 28 m3/min of air at 43°C dry bulb temperature and 15% relative humidity are mixed adiabatically with 14.0 m3/min of air at 18°Cdb temperature and 90% relative humidity. Calculate for the final Humidity Ratio (kgwv/kgda)? <Psat 43°C = 8.649 kPa, Psat 18°C = 2.064kPa>arrow_forwardOutdoor air at 35°C dry-bulb and 19°C dewpoint temperatures are to be mixed with room air at 26°C dry-bulb temperature and specific humidity of 0.0105 kgv/kga. The mass of outdoor air is one-third of the mass of the mixture. Find the following properties of the mixed air: Dry-bulb temperature Specific humidity Enthalpy Relative humidity Dewpoint temperature Specific volumearrow_forwardMoist air enters an air conditioning unit at 40°C dry bulb temperature and 45% relative humidity. The air is first passed over cooling coils to remove all of the moisture necessary to achieve the final moisture content and then is passed over heating coils to achieve the final conditions of 20°C dry bulb temperature and 10°C wet bulb temperature. The pressure remains constant at 1 atm throughout the process. (a) Sketch the psychometric diagram for the process. (b) Determine the dew point temperature of the mixture at the inlet of the cooling coils and at the inlet of the heating coils. (c) Calculate the net heat transfer for the entire process, in kJ/kg dry air.arrow_forward
- The air in a room (24.0°C and 30% humidity) with a volume of 96.6 m3 must be replaced every 5 minutes. Outside air at 38.0°C and 70% humidity is chilled to remove some of its water content and then dehumidified to the required temperature. What is the volumetric flow rate (in m3/min) of the humid air entering the chiller?arrow_forwardAir enters a cooling tower at a rate of 1100 cubic meters per minute, at 15°C and 65% relative humidity. Atmospheric pressure is 100 kPa. Water enters the tower at 38°C and leaves at 17°C. Air leaves the tower at 31°C and saturated. Using a psychrometric chart calculate the absolute humidity of the air leaving the cooling tower. 0.029 kg water vapour/kg air 0.069 kg water vapour/kg air O 0.0101 kg water vapour/kg air 0.364 kg water vapour/kg airarrow_forwardFor a typical sample of ambient air (at 30°C, 75% relative humidity and standard atmospheric pressure), the amount of moisture in kg per kg of dry air will be approximately, (a) 0.002 (b) 0.027 (c) 0.25 (d) 0.75arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY