What is the advantage of using solid-state devices in electronic control systems?
The advantage of electronic control systems using solid state devices.
Explanation of Solution
The term "solid state" and "semi-conductor" refers to the same electronic component; and signifies the different properties of electronic component. The term "solid state" indicates the physical description of component and the term "semi-conductor" refers to the electrical conductivity of component. The advantages of solid-state devices are smaller in size, ruggedness construction, increased life, speed response, and resistance to extreme environmental conditions.
Want to see more full solutions like this?
Chapter 12 Solutions
Bundle: Electricity For Refrigeration, Heating, And Air Conditioning, 10th + Lab Manual For Smith's Electricity For Refrigeration, Heating, And Air Conditioning, 9th
- What is opto-isolation?arrow_forwardName Section 5-2: Line Diagrams-Signals, Decisions, and Actions In the following application, a temperature switch controls a heating contactor and a flow switch is used to ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required information. 1. List all the signal devices in the circuit. 2. List all the action devices in the circuit. 3. List the decision part of the circuit that automatically sounds the alarm if there is a problem. 4. When the heating element is on during normal operation, is the flow switch open or closed? CIRCULATING 2 L1 FAN TEMPERATURE SWITCH TR HEATING ELEMENTS FLOW SWITCH -HOT AIR PADDLE AIR FILTER NORMALLY CLOSED FLOW SWITCH 65 ALARM (SOUNDS IF NO FLOW FOR 15 SECONDS OR MORE) Date HEATING CONTACTOR TR ON-DELAY TIMER SUPPLY AIR COLD AIR (3) TIME SET= 15 SEC © 2014 American Technical Publishers, Inc. All rights reservedarrow_forwardWhat is the purpose of the key switch located on the front of the CPU in many programmable logic controllers?arrow_forward
- How many layers of semiconductor material are used to construct an SCR?arrow_forwardIn a control circuit, it is imperative that a coil energize before another one. How can this be done when entering a program into the memory of the PLC?arrow_forwardChapter 18 Controlling a Preumatic System 461 Timing volume reservoir Goodheart-Willcox Publisher Figure 18-31, Timing-volume reservoirs allow ontrol of the sequence of a circuit using pilot-activated directional control valves.arrow_forward
- What are the four basic parts of a SCADA system. How can you classify the Programmable logic controllers? Why solenoid is used in almost all industrial applications?arrow_forwardWhy are NEMA symbols such as push buttons, float switches, or limit switches not used in programmable logic controller schematics?arrow_forwardWhich of the following is not a criteria in determining the control system performance? natural response time response O steady-state accuracy frequency responsearrow_forward
- What condition characterizes overcompounding?arrow_forwardCircuit Problem and Description: Using the given components, design a pneumatic circuit which will operate a double acting cylinder (A) from any one of two identical valves. The double acting cylinder will move out when either push button (M1) or (M2) is pressed, or when they are pressed at the same time. When the buttons are released, the cylinder will return to the initial position. Materials: Part # Component Description Quantity SAI 2026 Double acting cylinder SAI 2015 Normally closed 3/2 way valves operated by push button SAI 2023 Pneumatically piloted 5/2 way monostable valve SAI 2007 2 1 "OR" logic function valve 1 Teske Circuit Problem and Description: Using the given components, design a pneumatic circuit which will correctly and safely operate this machine control application. WWith this circuit, it must be possible to regulate the delay of a double acting cylinder (A). The cylinder will be driven by a valve, actuated by two pneumatic push buttons. One of the two push buttons…arrow_forwardThis is for my mechatronics class in regards to PLC and ladder diagrams It is common practice to include a NC contact after the coil to prevent overloading and overheating of a device such as a motor. True or Falsearrow_forward
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning