Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 10, Problem 10.9QAP
Interpretation Introduction
Interpretation:
The advantages of plasma sources over the flame sources for emission spectrometry needs to be explained.
Concept introduction:
Plasma sources spectroscopy a kind of mass spectrometry that detects metals as well as non-metals of low concentrations as one part in 1015 (part per quadrillion, ppq) on the low-background isotopes that involves plasma. Flame emission spectroscopy is a traditional method of spectroscopy. In this method, quantitative measurement of the optical emission obtained from the stimulated atoms are used to determine the concentration of an element that is to be analyzed.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Analytical Chemistry II
Compare between the advantages and disadvantages of atomic emission spectroscopy based on arcs and plasma.
DIfference between different types of UV spectrometers based on their advantages and disadvantages
Compare and contrast Flame Emission Spectrophotometry and Atomic Absorption Spectrophotometry
Chapter 10 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Describe the basic design difference between a spectrometer for absorption measurements and one for emission studies?arrow_forwardWhat are the main components of a spectrophotometer? Choose all that applies. radiation source sample compartment/holder monochromator detectorarrow_forwarddetector Answer Bank emission monochromator excitation monochromator light source sample cell ^ex A em It is typically a grating, prism, or filter that selects a narrow wavelength band of radiation and passes it to the sample. It holds the sample and has a defined pathlength. It is typically a photomultiplier tube that generates an electric signal when struck by photons. It is positioned 90° to the incident light and selects a narrow wavelength band of radiation to pass toarrow_forward
- Compare the advantages and disadvantages of the inductively coupled plasma and flames in atomic spectroscopy.arrow_forwardAtomic emission spectroscopy and the method of standard addition are used to determine the Na+ concentration and its uncertainty in an unknown sample. Increasing amounts of a 1.75 ug/mL standard Na+ solution are added to a series of volumetric flasks containing 15.00 mL of the unknown solution. The volumetric flasks are then diluted to a final volume of 200.0 mL. Atomic emission spectroscopy is then used to measure the emission intensity of each solution. Unknown volume Standard volume Final volume Emission (mL) (mL) (mL) intensity 15.00 0.00 200.0 351.0 15.00 5.00 200.0 494.0 15.00 10.00 200.0 642.0 15.00 15.00 200.0 807.0 15.00 20.00 200.0 948.0 Based on the data in the table, determine the original concentration of Nat and its uncertainty in the unknown sample. Report the uncertainty with three significant figures. concentration: ug/mL µg/mLarrow_forwardshow-all-working-explaining-detailly-each-step Answer should be typewritten using a computer keyboard.arrow_forward
- Compare the advantages and disadvantages of atomic absorption and inductively coupled plasma Atomic emission spectroscopy.arrow_forwardThe maximum number of spectra that can be recorded per second by ToF-MS is limited by the time taken by the slowest ions to go from the source to the detector. If the slowest ion took 45.6 microsecond to travel, at what frequency could you record spectra if a new extraction cycle were begun each time this heaviest ion reached the detector? 30000 spectra/s 10000 spectra/s 11000 spectra/s 500 spectra/s 22000 spectra/sarrow_forwardWhat is the relationship between the excitation wavelength (λex) and emission wavelength (λem) in atomic spectrophotometry (e.g. flame or furnace atomic absorption spectrophotometry)? Why is this different from molecular spectrophotometry?arrow_forward
- True or False: Emission spectroscopy can be used toidentify the components of paint’s pigmentsarrow_forwardExplain the principles of UV-Vis Spectrometerarrow_forwardInduction coupled plasma (ICP) emission spectrometry is widely used for the sensitive multi-element determinations. How does the ICP work?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning